The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Extraction of Proteins from Biological Fluids by Use of an Ionic Liquid/Aqueous Two‐Phase System
Abstract
An ionic liquid/aqueous two‐phase system based on the hydrophilic ionic liquid 1‐butyl‐3‐methylimidazolium chloride (BmimCl) and K 2 HPO 4 has been employed for direct extraction of proteins from human body fluids for the first time. Proteins present at low levels were quantitatively extracted into the BmimCl‐rich upper phase with a distribution ratio of about 10 between the upper and lower phase and an enrichment factor of 5. Addition of an appropriate amount of K 2 HPO 4 to the separated upper phase results in a further phase separation, giving rise to an improved enrichment factor of 20. FTIR and UV spectroscopy demonstrated that no chemical (bonding) interactions between the ionic liquid and the protein functional groups were identifiable, while no alterations of the natural properties of the proteins were observed. The partitioning of proteins in the two‐phase system was assumed to have been facilitated by the electrostatic potential difference between the coexisting phases, as well as by salting out effects. The system could be applied successfully for the quantification of proteins in human urine after on‐line phase separation in a flow system. The use of an ionic liquid, as a green solvent, offers clear advantages over traditional liquid–liquid extractions, in which the use of toxic organic solvents is unavoidable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Room-Temperature Ionic Liquids. Solvents for Synthesis and Catalysis
Welton, T. (1999) · Chemical Reviews · doi:10.1021/cr980032t · Cited by 11,852
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998) · Chem. Commun. · doi:10.1039/a803999b · Cited by 2,167
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Room Temperature Ionic Liquids from 20 Natural Amino Acids
Fukumoto, K., Yoshizawa, M., & Ohno, H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043451i · Cited by 1,236
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Task-specific ionic liquids for the extraction of metal ions from aqueous solutions
Visser, A. E., Swatloski, R. P., Reichert, W. M., Davis Jr., J. H., Rogers, R. D., Mayton, R., Sheff, S., & Wierzbicki, A. (2001) · Chemical Communications · doi:10.1039/b008041l · Cited by 920
Ionische Flüssigkeiten – neue „Lösungen“ für die Übergangsmetallkatalyse
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3757(20001103)112:21<3926::aid-ange3926>3.0.co;2-u · Cited by 650
Mechanisms of Lead Adsorption on Chitosan/PVA Hydrogel Beads
Jin, L., & Bai, R. (2002) · Langmuir · doi:10.1021/la025917l · Cited by 629
Enzyme catalysis in ionic liquids
Kragl, U., Eckstein, M., & Kaftzik, N. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00353-1 · Cited by 568
Protein solubilising and stabilising ionic liquids
Fujita, K., MacFarlane, D. R., & Forsyth, M. (2005) · Chemical Communications · doi:10.1039/b508238b · Cited by 476
Ionic Liquids in Analytical Chemistry
Anderson, J. L., Armstrong, D. W., & Wei, G.-T. (2006) · Analytical Chemistry · doi:10.1021/ac069394o · Cited by 467
Kimizuka, N., & Nakashima, T. (2001) · Langmuir · doi:10.1021/la015523e · Cited by 338
Luo, H., Dai, S., & Bonnesen, P. V. (2004) · Analytical Chemistry · doi:10.1021/ac035473d · Cited by 283
An expeditious solvent-free route to ionic liquids using microwaves
Varma, R. S., & Namboodiri, V. V. (2001) · Chemical Communications · doi:10.1039/b101375k · Cited by 278
He, C., Li, S., Liu, H., Li, K., & Liu, F. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.05.065 · Cited by 273
Raman studies of bovine serum albumin
Lin, V. J. C., & Koenig, J. L. (1976) · Biopolymers · doi:10.1002/bip.1976.360150114 · Cited by 272
Practical method to recycle a chiral (salen)Mn epoxidation catalyst by using an ionic liquid
Song, C. E., & Roh, E. J. (2000) · Chemical Communications · doi:10.1039/b001403f · Cited by 269
Temperature Behaviour of Human Serum Albumin
WETZEL, R., BECKER, M., BEHLKE, J., BILLWITZ, H., BoHM, S., EBERT, B., HAMANN, H., KRUMBIEGEL, J., & LASSMANN, G. (1980) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1980.tb04449.x · Cited by 248
Shimojo, K., & Goto, M. (2004) · Analytical Chemistry · doi:10.1021/ac049549x · Cited by 242
Greener Solvents: Room Temperature Ionic Liquids from Biorenewable Sources
Handy, S. T. (2003) · Chemistry – A European Journal · doi:10.1002/chem.200304799 · Cited by 206
Johansson, G. (1970) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(70)90283-7 · Cited by 178
Brauner, J. W., Flach, C. R., & Mendelsohn, R. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0400685 · Cited by 165
Laszlo, J. A., & Compton, D. L. (2002) · Journal of Molecular Catalysis B: Enzymatic · doi:10.1016/s1381-1177(02)00074-7 · Cited by 162
Solvent extraction of amino acids into a room temperature ionic liquid with dicyclohexano-18-crown-6
Smirnova, S. V., Torocheshnikova, I. I., Formanovsky, A. A., & Pletnev, I. V. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2398-8 · Cited by 160
Electromotive phenomena in partition of erythrocytes in aqueous polymer two phase systems
Reitherman, R., FLANAGAN, S., & Barondes, S. H. (1973) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(73)90065-2 · Cited by 145
Favre, F., Olivier‐Bourbigou, H., Commereuc, D., & Saussine, L. (2001) · Chemical Communications · doi:10.1039/b104155j · Cited by 142
Proteinuria in adults: a diagnostic approach.
Carroll, M. F., & Temte, J. L. (2000) · PubMed · Cited by 142
Purifying proteins for proteomics : a laboratory manual
Simpson, R. J. (2004) · Medical Entomology and Zoology · Cited by 131
Toxicity of organic extraction reagents to anaerobic bacteria
Playne, M., & Smith, B. F. (1983) · Biotechnology and Bioengineering · doi:10.1002/bit.260250508 · Cited by 126
Six methods for urinary protein compared.
McElderry, L. A., Tarbit, I., & Cassells-Smith, A. J. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.2.356 · Cited by 109
An Ionic Liquid Form of DNA: Redox-Active Molten Salts of Nucleic Acids
Leone, A. M., Weatherly, S. C., Williams, M. E., Thorp, H. H., & Murray, R. W. (2000) · Journal of the American Chemical Society · doi:10.1021/ja003332c · Cited by 105
Partition behavior of native proteins in aqueous dextran-poly(ethylene glycol)-phase systems
Sasakawa, S., & Walter, H. (1972) · Biochemistry · doi:10.1021/bi00765a004 · Cited by 79
Wang, J., & Hansen, E. H. (2002) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b204367j · Cited by 77
Self-citationAlbuminuria vs urinary total protein for detecting chronic renal disorders
Shihabi, Z. K., KONEN, J. C., & O'Connor, M. L. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.621 · Cited by 76
Wang, J. (2001) · Talanta · doi:10.1016/s0039-9140(01)00397-6 · Cited by 67
Self-citationDesign of successive ion conduction paths in DNA films with ionic liquids
Nishimura, N., & Ohno, H. (2002) · Journal of Materials Chemistry · doi:10.1039/b202972c · Cited by 56
Cited by
Ventura, S. P. M., e Silva, F. A., Quental, M. V., Mondal, D., Freire, M. G., & Coutinho, J. A. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00550 · Cited by 1,024
Aqueous two-phase system (ATPS): an overview and advances in its applications
Iqbal, M., Tao, Y., Xie, S., Zhu, Y., Chen, D., Wang, X., Huang, L., Peng, D., Sattar, A., Shabbir, M. A. B., et al. (2016) · Biological Procedures Online · doi:10.1186/s12575-016-0048-8 · Cited by 821
Aqueous biphasic systems: a boost brought about by using ionic liquids
Freire, M. G., Cláudio, A. F. M., Araújo, J. M. M., Coutinho, J. A. P., Marrucho, I. M., Lopes, J. N. C., & Rebelo, L. P. N. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35151j · Cited by 817
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Recent advances of enzymatic reactions in ionic liquids
Moniruzzaman, M., Nakashima, K., Kamiya, N., & Goto, M. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.10.002 · Cited by 450
Metadata
- Authors
- Du, Z., Yu, Y., & Wang, J.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2007-02-08
- Volume
- 13
- Issue
- 7
- Pages
- 2130-2137
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2144359296
- Cited by
- 319
- References
- 41
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.