The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Extraction of Proteins from Biological Fluids by Use of an Ionic Liquid/Aqueous Two‐Phase System
Abstract
An ionic liquid/aqueous two‐phase system based on the hydrophilic ionic liquid 1‐butyl‐3‐methylimidazolium chloride (BmimCl) and K 2 HPO 4 has been employed for direct extraction of proteins from human body fluids for the first time. Proteins present at low levels were quantitatively extracted into the BmimCl‐rich upper phase with a distribution ratio of about 10 between the upper and lower phase and an enrichment factor of 5. Addition of an appropriate amount of K 2 HPO 4 to the separated upper phase results in a further phase separation, giving rise to an improved enrichment factor of 20. FTIR and UV spectroscopy demonstrated that no chemical (bonding) interactions between the ionic liquid and the protein functional groups were identifiable, while no alterations of the natural properties of the proteins were observed. The partitioning of proteins in the two‐phase system was assumed to have been facilitated by the electrostatic potential difference between the coexisting phases, as well as by salting out effects. The system could be applied successfully for the quantification of proteins in human urine after on‐line phase separation in a flow system. The use of an ionic liquid, as a green solvent, offers clear advantages over traditional liquid–liquid extractions, in which the use of toxic organic solvents is unavoidable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Room-Temperature Ionic Liquids. Solvents for Synthesis and Catalysis
Welton, T. (1999) · Chemical Reviews · doi:10.1021/cr980032t · Cited by 11,852
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998) · Chem. Commun. · doi:10.1039/a803999b · Cited by 2,167
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Room Temperature Ionic Liquids from 20 Natural Amino Acids
Fukumoto, K., Yoshizawa, M., & Ohno, H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043451i · Cited by 1,236
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Cited by
Ventura, S. P. M., e Silva, F. A., Quental, M. V., Mondal, D., Freire, M. G., & Coutinho, J. A. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00550 · Cited by 1,024
Aqueous two-phase system (ATPS): an overview and advances in its applications
Iqbal, M., Tao, Y., Xie, S., Zhu, Y., Chen, D., Wang, X., Huang, L., Peng, D., Sattar, A., Shabbir, M. A. B., et al. (2016) · Biological Procedures Online · doi:10.1186/s12575-016-0048-8 · Cited by 821
Aqueous biphasic systems: a boost brought about by using ionic liquids
Freire, M. G., Cláudio, A. F. M., Araújo, J. M. M., Coutinho, J. A. P., Marrucho, I. M., Lopes, J. N. C., & Rebelo, L. P. N. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35151j · Cited by 817
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Recent advances of enzymatic reactions in ionic liquids
Moniruzzaman, M., Nakashima, K., Kamiya, N., & Goto, M. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.10.002 · Cited by 450
Ionic liquid-based aqueous two-phase extraction of selected proteins
Pei, Y., Wang, J., Wu, K., Xuan, X., & Lu, X. (2009) · Separation and Purification Technology · doi:10.1016/j.seppur.2008.10.010 · Cited by 418
Self-citationIonic Liquids as Tool to Improve Enzymatic Organic Synthesis
Itoh, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00158 · Cited by 394
Ionic Liquids in Chemical Engineering
Werner, S., Haumann, M., & Wasserscheid, P. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100915 · Cited by 373
Ionic liquid/water mixtures: from hostility to conciliation
Kohno, Y., & Ohno, H. (2012) · Chemical Communications · doi:10.1039/c2cc31638b · Cited by 366
Revisiting the Physicochemical Properties and Applications of Deep Eutectic Solvents
Ijardar, S. P., Singh, V., & Gardas, R. L. (2022) · Molecules · doi:10.3390/molecules27041368 · Cited by 363
Recent Advances in the Applications of Ionic Liquids in Protein Stability and Activity: A Review
Patel, R., Kumari, M., & Khan, A. B. (2014) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-014-0813-6 · Cited by 266
Deep eutectic solvents as novel extraction media for protein partitioning
Zeng, Q., Wang, Y., Huang, Y., Ding, X., Chen, J., & Xu, K. (2014) · The Analyst · doi:10.1039/c3an02235h · Cited by 263
How to Predict the Physical Properties of Ionic Liquids: A Volume‐Based Approach
Slattery, J. M., Daguenet, C., Dyson, P. J., Schubert, T. J. S., & Krossing, I. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700941 · Cited by 263
Li, H., Wang, Y., He, X., Chen, J., Xu, F., Liu, Z., & Zhou, Y. (2021) · Talanta · doi:10.1016/j.talanta.2021.122341 · Cited by 35
Metadata
- Authors
- Du, Z., Yu, Y., & Wang, J.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2007-02-08
- Volume
- 13
- Issue
- 7
- Pages
- 2130-2137
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2144359296
- Cited by
- 319
- References
- 41
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.