The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Nanostructured FeS as a Mimic Peroxidase for Biocatalysis and Biosensing
Abstract
Sheet‐like mimic enzyme: A novel nanostructure (see figure) of sheet‐like FeS with peroxidase‐like activity was synthesized as a mimic enzyme for the development of amperometric transducers and biocatalysts.magnified image Artificial enzyme mimics have attracted considerable interest due to easy denaturation and leakage of enzymes during their storage and immobilization procedure. Herein we describe the design of a novel mimic peroxidase, a nanostructure of sheet‐like FeS prepared by a simple micelle‐assisted synthetic method. Such a nanostructure has a large specific surface area and high peroxidase‐like activity, and was thus further used as a mimic enzyme for the development of biocatalysts and amperometric biosensors. The sheet‐like FeS nanostructure showed typical Michaelis–Menten kinetics and good affinity to both H 2 O 2 and 3,3′,5,5′‐tetramethyl benzidine. At pH 7.0 the constructed amperometric sensor showed a linear range for the detection of H 2 O 2 from 0.5 to 150 μ M with a correlation coefficient of 0.9998 without any electron transfer mediator. The H 2 O 2 sensor based on the sheet‐like FeS showed more sensitive response than those based on spherical FeS nanostructure, and resulted in a better stability than horseradish peroxidase when they were exposed to solutions with different pH values and temperatures. These excellent properties made the sheet‐like nanostructured FeS powerful tools for a wide range of potential applications as an “artificial peroxidase” as biosensors and biotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Silver nanoparticles: partial oxidation and antibacterial activities
Lok, C.-N., Ho, C.-M., Chen, R., He, Q.-Y., Yu, W.-Y., Sun, H., Tam, P. K.-H., Chiu, J.-F., & Che, C.-M. (2007) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-007-0208-z · Cited by 1,586
Wei, H., & Wang, E. (2008) · Analytical Chemistry · doi:10.1021/ac702203f · Cited by 1,412
Solubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Narayanan, R., & El-Sayed, M. A. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp051066p · Cited by 1,298
Biomimetic Chemistry and Artificial Enzymes: Catalysis by Design
Breslow, R. (1995) · Accounts of Chemical Research · doi:10.1021/ar00051a008 · Cited by 989
Rationally designed nanostructures for surface-enhanced Raman spectroscopy
Banholzer, M. J., Millstone, J. E., Qin, L., & Mirkin, C. A. (2008) · Chemical Society Reviews · doi:10.1039/b710915f · Cited by 795
Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00172-6 · Cited by 471
Self-citationPrussian Blue-Based First-Generation Biosensor. A Sensitive Amperometric Electrode for Glucose
Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E. (1995) · Analytical Chemistry · doi:10.1021/ac00110a016 · Cited by 456
Karyakin, A. A., Karyakina, E. E., & Gorton, L. (2000) · Analytical Chemistry · doi:10.1021/ac990801o · Cited by 419
Shape Control of Thermodynamically Stable Cobalt Nanorods through Organometallic Chemistry
Dumestre, F., Chaudret, B., Amiens, C., Fromen, M.-C., Casanove, M.-J., Renaud, P., & Zurcher, P. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20021115)41:22<4286::aid-anie4286>3.0.co;2-m · Cited by 365
Shoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 343
Prussian Blue Based Nanoelectrode Arrays for H2O2 Detection
Karyakin, A. A., Puganova, E. A., Budashov, I. A., Kurochkin, I. N., Karyakina, E. E., Levchenko, V. A., Matveyenko, V. N., & Varfolomeyev, S. D. (2004) · Analytical Chemistry · doi:10.1021/ac034859l · Cited by 324
Liu, S.-Q., & Ju, H.-X. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00014-3 · Cited by 273
Self-citationZhang, M., Liu, K., Xiang, L., Lin, Y., Su, L., & Mao, L. (2007) · Analytical Chemistry · doi:10.1021/ac0705871 · Cited by 232
Bonar-Law, R. P., & Sanders, J. K. M. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00106a029 · Cited by 227
Li, J., Qiu, J. ‐., Xu, J. ‐., Chen, H. ‐., & Xia, X. ‐. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200600033 · Cited by 215
Hematin as a peroxidase substitute in hydrogen peroxide determinations
Zhang, G., & Dasgupta, P. K. (1992) · Analytical Chemistry · doi:10.1021/ac00029a013 · Cited by 210
Wu, S., Ju, H. X., & Liu, Y. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200600491 · Cited by 187
Self-citationSurfactant promoting effects on clathrate hydrate formation: Are micelles really involved?
Profio, P. D., Arca, S., Germani, R., & Savelli, G. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2005.02.051 · Cited by 138
Nonenzymatic Detection of Bacterial Genomic DNA Using the Bio Bar Code Assay
Hill, H. D., Vega, R. A., & Mirkin, C. A. (2007) · Analytical Chemistry · doi:10.1021/ac701626y · Cited by 127
Talapin, D. V., Yu, H., Shevchenko, E. V., Lobo, A., & Murray, C. B. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp074319i · Cited by 121
Synthesis and Characterization of Magnetic Iron Sulfide Nanowires
Nath, M., Choudhury, A., Kundu, A. K., & Rao, C. N. R. (2003) · Advanced Materials · doi:10.1002/adma.200306042 · Cited by 114
Aswal, V. K., & Goyal, P. S. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(02)01833-x · Cited by 97
Zong, S., Cao, Y., Zhou, Y., & Ju, H. (2006) · Langmuir · doi:10.1021/la060930h · Cited by 87
Self-citationEnzyme nanoparticles-based electronic biosensor
Liu, G., Lin, Y., Ostatná, V., & Wang, J. (2005) · Chemical Communications · doi:10.1039/b504943a · Cited by 85
Shan, D., Zhu, M., Han, E., Xue, H., & Cosnier, S. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.07.012 · Cited by 73
Liu, Z., Cai, R., Mao, L., Huang, H., & Ma, W. (1999) · The Analyst · doi:10.1039/a807027j · Cited by 64
New materials based on nanostructured Prussian blue for development of hydrogen peroxide sensors
Puganova, E. A., & Karyakin, A. A. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.03.094 · Cited by 51
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Nanozymes: Classification, Catalytic Mechanisms, Activity Regulation, and Applications
Huang, Y., Ren, J., & Qu, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00672 · Cited by 3,523
Reactive Oxygen Species (ROS)-Based Nanomedicine
Yang, B., Chen, Y., & Shi, J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00626 · Cited by 2,443
Standardized assays for determining the catalytic activity and kinetics of peroxidase-like nanozymes
Jiang, B., Duan, D., Gao, L., Zhou, M., Fan, K., Tang, Y., Xi, J., Bi, Y., Tong, Z., Gao, G. F., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0001-1 · Cited by 1,300
Nanostructured metal sulfides for energy storage
Rui, X., Tan, H., & Yan, Q. (2014) · Nanoscale · doi:10.1039/c4nr03057e · Cited by 1,003
Metadata
- Authors
- Dai, Z., Liu, S., Bao, J., & Ju, H.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2009-04-15
- Volume
- 15
- Issue
- 17
- Pages
- 4321-4326
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2128242014
- Cited by
- 312
- References
- 29
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.