The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
BODIPY‐Based Fluorescent Probes for Biothiols
Abstract
Fluorescent probes for biothiols have aroused increasing interest owing to their potential to enable better understanding of the diverse physiological and pathological processes related to the biothiol species. BODIPY fluorophores exhibit excellent optical properties, which can be readily tailored by introducing diverse functional units at various positions of the BODIPY core. In the present review, the development of fluorescent probes based on BODIPYs for the detection of biothiols are systematically summarized, with emphasis on the preferable detection of individual biothiols, as well as simultaneous discrimination among cysteine (Cys), homocysteine (Hcy), reduced glutathione (GSH). In addition, organelle‐targeting probes for biothiols are also highlighted. The general design principles, various recognition mechanisms, and biological applications are elaboratively discussed, which could provide a useful reference to researchers worldwide interested in this area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Pittet, M. J., & Weissleder, R. (2011) · Cell · doi:10.1016/j.cell.2011.11.004 · Cited by 466
Cited by
J-aggregates of meso-[2.2]paracyclophanyl-BODIPY dye for NIR-II imaging
Li, K., Duan, X., Jiang, Z., Ding, D., Chen, Y., Zhang, G.-Q., & Liu, Z. (2021) · Nature Communications · doi:10.1038/s41467-021-22686-z · Cited by 301
Cheng, H., Cao, X., Zhang, S., Zhang, K., Cheng, Y., Wang, J., Zhao, J., Zhou, L., Liang, X., & Yoon, J. (2023) · Advanced Materials · doi:10.1002/adma.202207546 · Cited by 260
Self-citation
Metadata
- Authors
- Zhang, J., Wang, N., Ji, X., Tao, Y., Wang, J., & Zhao, W.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2020-01-21
- Volume
- 26
- Issue
- 19
- Pages
- 4172-4192
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2990559666
- Cited by
- 237
- References
- 5
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BODIPY‐Based Fluorescent Probes for Biothiols. https://app.cochat.ai/papers/10.1002/chem.201904470
- The paper
- Zhang, J., Wang, N., Ji, X., Tao, Y., Wang, J., & Zhao, W. (2020). BODIPY‐Based Fluorescent Probes for Biothiols. Chemistry – A European Journal. https://doi.org/10.1002/chem.201904470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.