Combining Mechanistic Modeling and Raman Spectroscopy for Real‐Time Monitoring of Fed‐Batch Penicillin Production
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A soft sensor that combines data from Raman spectroscopy and off‐gas analyzers with a dynamic mechanistic bioprocess model was investigated for online monitoring of the physiological characteristics of Penicillium chrysogenum fed‐batch cultivations. A systematic workflow based on nonlinear observability analysis was established for accelerating and improving the process of soft‐sensor development. Using in situ Raman spectroscopy, it was possible to perform accurate and frequent measurements of the penicillin concentration in the bioreactor, which were combined with measurements of respiratory rates. Using a particle filter algorithm, the soft sensor allowed for the online estimation of the biomass concentration, the specific growth rate, and the specific penicillin production rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal State Estimation: Kalman, H∞, and Nonlinear Approaches
Simon, D. (2006) · doi:10.1002/0470045345 · Cited by 4,875
Nonlinear controllability and observability
Hermann, R., & Krener, A. (1977) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1977.1101601 · Cited by 2,374
Data-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845
Soft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238
Pirt, S. J., & Righelato, R. C. (1967) · Applied Microbiology · doi:10.1128/aem.15.6.1284-1290.1967 · Cited by 157
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
On-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“[60] combined a mechanistic model with Raman spectroscopy for the real-time monitoring of fed-batch penicillin production.”
Metadata
- Authors
- Golabgir, A., & Herwig, C.
- Venue
- Chemie Ingenieur Technik
- Publisher
- Wiley
- Published
- 2016-03-23
- Volume
- 88
- Issue
- 6
- Pages
- 764-776
- ISSN
- 0009-286X (ISSN-L)
- 1522-2640
- OpenAlex
- W2306759795
- Cited by
- 47
- References
- 5
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combining Mechanistic Modeling and Raman Spectroscopy for Real‐Time Monitoring of Fed‐Batch Penicillin Production. https://app.cochat.ai/papers/10.1002/cite.201500101
- The paper
- Golabgir, A., & Herwig, C. (2016). Combining Mechanistic Modeling and Raman Spectroscopy for Real‐Time Monitoring of Fed‐Batch Penicillin Production. Chemie Ingenieur Technik. https://doi.org/10.1002/cite.201500101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.