Feasibility of Extended Ambulatory Electrocardiogram Monitoring to Identify Silent Atrial Fibrillation in High‐risk Patients: The Screening Study for Undiagnosed Atrial Fibrillation (STUDY‐AF)
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Identification of silent atrial fibrillation (AF) could prevent stroke and other sequelae. Hypothesis: Screening for AF using continuous ambulatory electrocardiographic (ECG) monitoring can detect silent AF in asymptomatic in patients with known risk factors. Methods: We performed a single‐center prospective screening study using a wearable patch‐based device that provides up to 2 weeks of continuous ambulatory ECG monitoring (iRhythm Technologies, Inc.). Inclusion criteria were age ≥55 years and ≥2 of the following risk factors: coronary disease, heart failure, hypertension, diabetes, sleep apnea. We excluded patients with prior AF, stroke, transient ischemic attack, implantable pacemaker or defibrillator, or with palpitations or syncope in the prior year. Results: Out of 75 subjects (all male, age 69 ± 8.0 years; ejection fraction 57% ± 8.7%), AF was detected in 4 subjects (5.3%; AF burden 28% ± 48%). Atrial tachycardia (AT) was present in 67% (≥4 beats), 44% (≥8 beats), and 6.7% (≥60 seconds) of subjects. The combined diagnostic yield of sustained AT/AF was 11%. In subjects without sustained AT/AF, 11 (16%) had ≥30 supraventricular ectopic complexes per hour. Conclusions: Outpatient extended ECG screening for asymptomatic AF is feasible, with AF identified in 1 in 20 subjects and sustained AT/AF identified in 1 in 9 subjects, respectively. We also found a high prevalence of asymptomatic AT and frequent supraventricular ectopic complexes, which may be relevant to development of AF or stroke. If confirmed in a larger study, primary screening for AF could have a significant impact on public health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Goldstein, L. B., Bushnell, C. D., Adams, R. J., Appel, L. J., Braun, L. T., Chaturvedi, S., Creager, M. A., Culebras, A., Eckel, R. H., Hart, R. G., et al. (2011) · Stroke · doi:10.1161/str.0b013e3181fcb238 · Cited by 1,306 · cited 1×
“6,7 However,thisdiagnosticapproach can be unreliable due to infrequent and inconsistent sampling, particularly among asymptomatic patients, who are less likely to seek medical care.”
Atrial Fibrillation: A Major Contributor to Stroke in the Elderly: The Framingham Study
Wolf, P. A. (1987) · Archives of Internal Medicine · doi:10.1001/archinte.1987.00370090041008 · Cited by 1,108
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 1×
“32 A separate subgroup analysis of TRENDS reported that 28% of patientswithpriorTEinthecohortwerenewlydetectedwith AT/AF during the study.”
Excessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and Stroke
Binici, Z., Intzilakis, T., Nielsen, O. W., Køber, L., & Sajadieh, A. (2010) · Circulation · doi:10.1161/circulationaha.109.874982 · Cited by 379
Flaker, G. C., Belew, K., Beckman, K., Vidaillet, H., Kron, J., Safford, R., Mickel, M., & Barrell, P. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.06.032 · Cited by 341
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationTurakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Self-citationChen, L. Y., Chung, M. K., Allen, L. A., Ezekowitz, M., Furie, K. L., McCabe, P., Noseworthy, P. A., Perez, M. V., & Turakhia, M. P. (2018) · Circulation · doi:10.1161/cir.0000000000000568 · Cited by 439
Self-citationThe impact of wearable technologies in health research: scoping review
Huhn, S., Axt, M., Gunga, H.-C., Maggioni, M. A., Munga, S., Obor, D., Sié, A., Boudo, V., Bunker, A., Sauerborn, R., et al. (2022) · JMIR mHealth and uHealth · doi:10.2196/34384 · Cited by 379
Wearable Devices for Ambulatory Cardiac Monitoring
Sana, F., Isselbacher, E. M., Singh, J. P., Heist, E. K., Pathik, B., & Armoundas, A. A. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.01.046 · Cited by 362
“Along these lines, a screening study that was performed to examine the effectiveness of a wearable patch in detecting AF, using continuous ECG monitoring of asymptomatic patients with known risk factors, identified AF in 1 in 20 subjects with no prior AF history, a finding with significant public health impact (40).”
BackgroundReiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3180 · Cited by 265
Screening for atrial fibrillation: a call for evidence
Jones, N. R., Taylor, C. J., Hobbs, F. D. R., Bowman, L., & Casadei, B. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz834 · Cited by 178
Accuracy of mHealth Devices for Atrial Fibrillation Screening: Systematic Review
Giebel, G. D., & Gissel, C. (2019) · JMIR mHealth and uHealth · doi:10.2196/13641 · Cited by 99
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Self-citationNewer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Metadata
- Authors
- Turakhia, M. P., Ullal, A. J., Hoang, D. D., Than, C. T., Miller, J. D., Friday, K. J., Perez, M. V., Freeman, J. V., Wang, P. J., & Heidenreich, P. A.
- Venue
- Clinical Cardiology
- Publisher
- Wiley
- Published
- 2015-04-14
- Volume
- 38
- Issue
- 5
- Pages
- 285-292
- ISSN
- 0160-9289 (ISSN-L)
- 1932-8737
- OpenAlex
- W2165093902
- Cited by
- 98
- References
- 17
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.