CoChat

Diagnostic Yield and Optimal Duration of Continuous-Loop Event Monitoring for the Diagnosis of Palpitations: A Cost-Effectiveness Analysis

Zimetbaum, Peter J., Kim, Kelly Y., Josephson, Mark E., Goldberger, Ary L., Cohen, David J. · 1998 · Annals of Internal Medicine

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.

Overview

Integrity signals

Registry

Crossref · 10.7326/0003-4819-128-11-199806010-00002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 7 references

Cited by

See all 145

Metadata

Authors
Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J.
Affiliations
Beth Israel Deaconess Medical Center (US)
Corresponding author
Zimetbaum, Peter J.
Venue
Annals of Internal Medicine
Published
1998-06-01
Volume
128
Issue
11
Pages
890-895
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1967172540
Cited by
133
References
7
Citations by year
2026: 1 · 2025: 1 · 2023: 2 · 2022: 6 · 2021: 12 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 4 · 2014: 9 · 2013: 8 · 2012: 5
FWCI
3.53
Type
journal article
Language
en
Open access
closed
Licence
www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
Locations
  • Annals of Internal Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
palpitations, diagnostic yield, monitoring duration, cost-effectiveness, event data recorders, arrhythmia diagnosis, incremental cost-effectiveness ratio
MeSH terms
Adult, Aged, Arrhythmias, Cardiac, Cost-Benefit Analysis, Costs and Cost Analysis, Female, Humans, Male, Middle Aged, Prospective Studies, Time Factors, Electrocardiography, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Yield and Optimal Duration of Continuous-Loop Event Monitoring for the Diagnosis of Palpitations: A Cost-Effectiveness Analysis. https://app.cochat.ai/papers/10.7326/0003-4819-128-11-199806010-00002
The paper
Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J. (1998). Diagnostic Yield and Optimal Duration of Continuous-Loop Event Monitoring for the Diagnosis of Palpitations: A Cost-Effectiveness Analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-128-11-199806010-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.