CoChat

Firing features and potassium channel content of murine spiral ganglion neurons vary with cochlear location

Adamson, Crista L., Reid, Michael A., Mo, Zun‐Li, Bowne‐English, Janet, Davis, Robin L. · 2002 · Journal of Comparative Neurology
Cited by 182

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Neurons from varied regions of the central nervous system can show widely divergent responses to electrical stimuli that are determined by cell‐specific differences in ion channel composition. The well‐ordered and highly characterized peripheral auditory system allows one to explore the significance of this diversity during the final stages of postnatal development. We examined the electrophysiological features of murine spiral ganglion neurons in vitro at a time when recordings could be made from the cell bodies before myelination. These cells carry information about sound stimuli from hair cell receptors in the basilar membrane and are arranged tonotopically. Spiral ganglion neuron responses to depolarizing current injection were assessed with whole‐cell current clamp recordings from cells that were isolated separately from the apical and basal thirds of the mouse cochlea. These cells displayed systematic variation in their firing. Apex neurons (low frequency coding) showed longer latency, slowly adapting responses, whereas base neurons (high frequency coding) showed short latency, rapidly adapting responses to the same stimuli. This physiological diversity was mirrored by regional differences in ion channel content assessed immunohistochemically. Apex neurons had a preponderance of Kv4.2 subunits, whereas base neurons possessed greater levels of K Ca, Kv1.1, and Kv3.1 subunits. Taken together, these results indicate that the distribution of a set of voltage‐gated potassium channels may relate specifically to a particular range of coding frequencies. These studies also suggest that intrinsic properties of spiral ganglion neurons can contribute to the characteristic responses of the peripheral auditory system. Their potential role in development and adult function is discussed. J. Comp. Neurol. 447:331–350, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cne.10244

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 182

Metadata

Authors
Adamson, C. L., Reid, M. A., Mo, Z., Bowne‐English, J., & Davis, R. L.
Venue
Journal of Comparative Neurology
Publisher
Wiley
Published
2002-04-29
Volume
447
Issue
4
Pages
331-350
ISSN
  • 0021-9967 (ISSN-L)
  • 1096-9861
OpenAlex
W1992995631
Cited by
182
References
4
FWCI
2.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Firing features and potassium channel content of murine spiral ganglion neurons vary with cochlear location. https://app.cochat.ai/papers/10.1002/cne.10244
The paper
Adamson, C. L., Reid, M. A., Mo, Z., Bowne‐English, J., & Davis, R. L. (2002). Firing features and potassium channel content of murine spiral ganglion neurons vary with cochlear location. Journal of Comparative Neurology. https://doi.org/10.1002/cne.10244

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.