A guide to uncertainty quantification and sensitivity analysis for cardiovascular applications
The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Summary: As we shift from population‐based medicine towards a more precise patient‐specific regime guided by predictions of verified and well‐established cardiovascular models, an urgent question arises: how sensitive are the model predictions to errors and uncertainties in the model inputs? To make our models suitable for clinical decision‐making, precise knowledge of prediction reliability is of paramount importance. Efficient and practical methods for uncertainty quantification (UQ) and sensitivity analysis (SA) are therefore essential. In this work, we explain the concepts of global UQ and global, variance‐based SA along with two often‐used methods that are applicable to any model without requiring model implementation changes: Monte Carlo (MC) and polynomial chaos (PC). Furthermore, we propose a guide for UQ and SA according to a six‐step procedure and demonstrate it for two clinically relevant cardiovascular models: model‐based estimation of the fractional flow reserve (FFR) and model‐based estimation of the total arterial compliance (CT). Both MC and PC produce identical results and may be used interchangeably to identify most significant model inputs with respect to uncertainty in model predictions of FFR and CT. However, PC is more cost‐efficient as it requires an order of magnitude fewer model evaluations than MC. Additionally, we demonstrate that targeted reduction of uncertainty in the most significant model inputs reduces the uncertainty in the model predictions efficiently. In conclusion, this article offers a practical guide to UQ and SA to help move the clinical application of mathematical models forward. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
Design and Analysis of Computer Experiments
Sacks, J., Welch, W. J., Mitchell, T. J., & Wynn, H. P. (1989) · Statistical Science · doi:10.1214/ss/1177012413 · Cited by 6,919
Global Sensitivity Analysis. The Primer
Saltelli, A., Ratto, M., Andres, T., Campolongo, F., Cariboni, J., Gatelli, D., Saisana, M., & Tarantola, S. (2007) · doi:10.1002/9780470725184 · Cited by 6,430
Global sensitivity indices for nonlinear mathematical models and their monte carlo estimates
Sobol′, I. M. (2001) · Mathematics and Computers in Simulation · doi:10.1016/s0378-4754(00)00270-6 · Cited by 6,389
Factorial Sampling Plans for Preliminary Computational Experiments
Morris, M. D. (1991) · Technometrics · doi:10.1080/00401706.1991.10484804 · Cited by 4,943
The Wiener--Askey Polynomial Chaos for Stochastic Differential Equations
Xiu, D., & Karniadakis, G. E. (2002) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827501387826 · Cited by 4,807 · cited 10×
“The type of univariate polynomial ̨i is determined by the distribution of input Zi according to the Wiener–Askey scheme [19].”
BackgroundMethodInfluentialFractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
McKay, M. D., Beckman, R. J., & Conover, W. J. (1979) · Technometrics · doi:10.2307/1268522 · Cited by 3,757
Handbook of Stochastic Methods for Physics, Chemistry and the Natural Sciences
Gardiner, C. W. (1985) · Springer Series in Synergetics · doi:10.1007/978-3-662-02452-2 · Cited by 3,703
Saltelli, A., Annoni, P., Azzini, I., Campolongo, F., Ratto, M., & Tarantola, S. (2010) · Computer Physics Communications · doi:10.1016/j.cpc.2009.09.018 · Cited by 3,623
Wiener, N. (1938) · American Journal of Mathematics · doi:10.2307/2371268 · Cited by 3,074
Remarks on a Multivariate Transformation
Rosenblatt, M. (1952) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729394 · Cited by 2,863 · cited 1×
“For the PC method, the state of the art approach is to transform the dependent random variables to independent random variables with, for example, a Nataf [108] or Rosenblatt transformation [109], or to construct a dependent orthogonal expansion directly [110].”
MethodGlobal sensitivity analysis using polynomial chaos expansions
Sudret, B. (2008) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2007.04.002 · Cited by 2,539 · cited 5×
“Often, the L(2)-norm is used, which reduces (30) to the following linear least squares problem [21]: 2 (6)6664 ˆ0 z ˆ1 z : : : ˆNp 1 z ˆ0 z ˆ1 z : : : ˆNp 1 z :: :: : : : :: ˆ0 zs ˆ1 zs : : : ˆNp 1 zs 3 (7)7775 „ ƒ‚ .”
BackgroundMethodInfluentialMaking best use of model evaluations to compute sensitivity indices
Saltelli, A. (2002) · Computer Physics Communications · doi:10.1016/s0010-4655(02)00280-1 · Cited by 2,228 · cited 3×
“We now present Saltelli’s efficient numerical procedure to estimate the main and total sensitivity indices as presented in [57].”
BackgroundMethodInfluentialPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · cited 2×
“, sphygmanometry [12]) as well as large biological variability (e.”
BackgroundMethodImportance measures in global sensitivity analysis of nonlinear models
Homma, T., & Saltelli, A. (1996) · Reliability Engineering & System Safety · doi:10.1016/0951-8320(96)00002-6 · Cited by 2,011
An effective screening design for sensitivity analysis of large models
Campolongo, F., Cariboni, J., & Saltelli, A. (2007) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2006.10.004 · Cited by 2,011 · cited 1×
“The elementary effects method of Morris can be used to screen for uncertain inputs that have a non-significant effect on a model output at a relative low number of model evaluations [93, 94].”
MethodSensitivity Analysis in Practice: A Guide to Assessing Scientific Models
McCulloch, A. (2005) · Journal of the Royal Statistical Society Series A: Statistics in Society · doi:10.1111/j.1467-985x.2005.358_16.x · Cited by 1,842 · cited 1×
“In case of dependent inputs, the sensitivity analysis based on the Sobol decomposition is no longer applicable because the sensitivities are no longer additive and thus difficult to interpret [104].”
MethodMonte Carlo and quasi-Monte Carlo methods
Caflisch, R. E. (1998) · Acta Numerica · doi:10.1017/s0962492900002804 · Cited by 1,754 · cited 2×
“Such alternative sample schemes prevent clustering of samples and ensure that samples fully cover the input space [45].”
BackgroundUncertain Judgements: Eliciting Experts' Probabilities
O'Hagan, A., Buck, C. E., Daneshkhah, A., Eiser, J. R., Garthwaite, P. H., Jenkinson, D. J., Oakley, J. E., & Rakow, T. (2006) · doi:10.1002/0470033312 · Cited by 1,550
High-Order Collocation Methods for Differential Equations with Random Inputs
Xiu, D., & Hesthaven, J. S. (2005) · SIAM Journal on Scientific Computing · doi:10.1137/040615201 · Cited by 1,522 · cited 2×
“Examples of non-intrusive global methods are the Monte Carlo (MC) method [20], the PC method [21, 22], and the Lagrangian interpolation method [23, 24].”
MethodAdaptive sparse polynomial chaos expansion based on least angle regression
Blatman, G., & Sudret, B. (2011) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.12.021 · Cited by 1,502 · cited 1×
“have also introduced alternative algorithms that adaptively build up the PC expansion until some target accuracy is obtained [68, 95, 96].”
BackgroundTaylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Fishman, G. S. (1996) · Springer eBooks · doi:10.1007/978-1-4757-2553-7 · Cited by 925
Numerical integration using sparse grids
Gerstner, T., & Griebel, M. (1998) · Numerical Algorithms · doi:10.1023/a:1019129717644 · Cited by 923 · cited 1×
“Sparse grids quadratures are constructed from onedimensional quadrature rules using Smolyak’s algorithm [71, 72].”
MethodBlood pressure and heart rate variabilities in normotensive and hypertensive human beings.
Mancia, G., Ferrari, A., Gregorini, L., Parati, G., Pomidossi, G., Bertinieri, G., Grassi, G., di Rienzo, M., Pedotti, A., & Zanchetti, A. (1983) · Circulation Research · doi:10.1161/01.res.53.1.96 · Cited by 776 · cited 2×
“, heart rate, mean blood pressure [13]), leading to uncertainties in the inputs.”
BackgroundPolynomial chaos expansion for sensitivity analysis
Crestaux, T., Maître, O. P. L., & Martinez, J. (2008) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2008.10.008 · Cited by 748 · cited 4×
“The PC expansion is expressed in terms of the orthogonal polynomials and expansion coefficients, which can already be obtained with a relatively low number of input samples [19, 21, 22].”
BackgroundMethodInfluentialA Matlab toolbox for Global Sensitivity Analysis
Pianosi, F., Sarrazin, F., & Wagener, T. (2015) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2015.04.009 · Cited by 653 · cited 2×
“Software toolboxes that support quasi-random sampling and Latin hypercube sampling can be found in, for example, [Python] Chaospy [51], Dakota [52], [Scilab] NISP [53], [MATLAB] SAFE [54], and [R] Sensitivity [55].”
MethodAnalysis of variance designs for model output
Jansen, M. J. W. (1999) · Computer Physics Communications · doi:10.1016/s0010-4655(98)00154-4 · Cited by 650
Nobile, F., Tempone, R. F., & Webster, C. (2008) · SIAM Journal on Numerical Analysis · doi:10.1137/070680540 · Cited by 617 · cited 1×
“Adaptive dimension algorithms for sparse grids have been developed [97, 98].”
BackgroundMonte Carlo theory and practice
James, F. (1980) · Reports on Progress in Physics · doi:10.1088/0034-4885/43/9/002 · Cited by 544 · cited 1×
“For more information on MC, we refer the interested reader to [20, 49, 50].”
BackgroundDimension?Adaptive Tensor?Product Quadrature
Gerstner, T., & Griebel, M. (2003) · Computing · doi:10.1007/s00607-003-0015-5 · Cited by 544 · cited 1×
“Adaptive dimension algorithms for sparse grids have been developed [97, 98].”
BackgroundComputer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
Low-discrepancy and low-dispersion sequences
Niederreiter, H. (1988) · Journal of Number Theory · doi:10.1016/0022-314x(88)90025-x · Cited by 491 · cited 1×
“In the latter case, samples are constructed from deterministic Halton, Sobol, or Fauré sequences [47, 48].”
BackgroundNumerical Challenges in the Use of Polynomial Chaos Representations for Stochastic Processes
Debusschere, B., Najm, H. N., Pébaÿ, P., Knio, O., Ghanem, R., & Maître, O. P. L. (2004) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827503427741 · Cited by 451 · cited 1×
“Various implementations for different programming environments are as follows: [Python] Chaospy [51], Dakota [52], [CCC] MITUQ [63], [Scilab] NISP [53], [Python] OpenTurns [64], and [CCC] UQToolkit [65].”
MethodThe stochastic finite element method: basic perturbation technique and computer implementation
(1993) · Choice Reviews Online · doi:10.5860/choice.31-0328 · Cited by 400 · cited 1×
“Examples of intrusive global methods are the perturbation method [15, 16], the moment equation approach [17], and the stochastic spectral Galerkin method (an intrusive polynomial chaos (PC) method) [18, 19].”
MethodEstimating the approximation error when fixing unessential factors in global sensitivity analysis
Sobol’, I. M., Tarantola, S., Gatelli, D., Kucherenko, S. S., & Mauntz, W. (2007) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2006.07.001 · Cited by 394
Efficient computation of global sensitivity indices using sparse polynomial chaos expansions
Blatman, G., & Sudret, B. (2010) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2010.06.015 · Cited by 383
Quasi-Random Sequences and Their Discrepancies
Morokoff, W. J., & Caflisch, R. E. (1994) · SIAM Journal on Scientific Computing · doi:10.1137/0915077 · Cited by 377 · cited 1×
“In the latter case, samples are constructed from deterministic Halton, Sobol, or Fauré sequences [47, 48].”
BackgroundEstimation of global sensitivity indices for models with dependent variables
Kucherenko, S., Tarantola, S., & Annoni, P. (2012) · Computer Physics Communications · doi:10.1016/j.cpc.2011.12.020 · Cited by 347
Vascular Compliance and Cardiovascular Disease A Risk Factor or a Marker?
Glasser, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00311-7 · Cited by 308
Morris, P. D., Ryan, D., Morton, A. C., Lycett, R., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.08.024 · Cited by 270 · cited 1×
“The pressures proximal and distal to the stenosis are assessed using 3-D computational fluid dynamics (CFD) simulations on a patient-specific coronary artery domains [79, 80].”
MethodMonte Carlo Confidence Intervals
Buckland, S. T. (1984) · Biometrics · doi:10.2307/2530926 · Cited by 257 · cited 1×
“Alternatives to this method may be found in [56].”
MethodVariance-based sensitivity indices for models with dependent inputs
Mara, T. A., & Tarantola, S. (2012) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2011.08.008 · Cited by 246
Eldred, M., Swiler, L. P., & Tang, G. (2011) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2010.11.010 · Cited by 220
Use of pulse pressure method for estimating total arterial compliance in vivo
Stergiopulos, N., Segers, P., & Westerhof, N. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h424 · Cited by 211 · cited 1×
“, non-invasive) clinical measurements of systolic and diastolic pressures [85, 86].”
BackgroundA patient-specific computational model of fluid–structure interaction in abdominal aortic aneurysms
Wolters, B. J. B. M., Rutten, M. C. M., Schurink, G. W. H., Kose, U., de Hart, J., & van de Vosse, F. N. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.06.008 · Cited by 185 · cited 1×
“More recently, engineers started aiming to apply these models for individualized diagnosis and intervention planning in the clinic [10, 11].”
BackgroundStergiopulos, N., Meister, J. J., & Westerhof, N. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368245 · Cited by 173 · cited 1×
“, non-invasive) clinical measurements of systolic and diastolic pressures [85, 86].”
BackgroundAdaptive Smolyak Pseudospectral Approximations
Marzouk, Y., & Conrad, P. R. (2013) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 169
The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm
Speelman, L., Schurink, G. W. H., Bosboom, E. M., Buth, J., Breeuwer, M. M., van de Vosse, F. N., & Jacobs, M. J. H. M. (2009) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2009.08.075 · Cited by 163
Sankaran, S., & Marsden, A. L. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4003259 · Cited by 146
Smolyak cubature of given polynomial degree with few nodes for increasing dimension
Petras, K. (2003) · Numerische Mathematik · doi:10.1007/s002110200401 · Cited by 123 · cited 1×
“The total number of samples Ns in the sparse grid are less than the tensored quadrature when using the same one-dimensional rule, but an additional approximation error is introduced (for specific approximation error bounds, see [73, 74]).”
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
A Bayesian Approach for Global Sensitivity Analysis of (Multifidelity) Computer Codes
Gratiet, L. L., Cannamela, C., & Iooss, B. (2014) · SIAM/ASA Journal on Uncertainty Quantification · doi:10.1137/130926869 · Cited by 120
Aortic compliance in human hypertension.
Liu, Z. R., Ting, C.-T., Zhu, S., & Yin, F. C. P. (1989) · Hypertension · doi:10.1161/01.hyp.14.2.129 · Cited by 116 · cited 1×
“The results for example 2 (CT-estimation) show that the PP method estimates CT with an amount of uncertainty that is too large compared with the differences observed between healthy and hypertensive individuals [90].”
MethodGeneralized Sobol sensitivity indices for dependent variables: numerical methods
Chastaing, G., Gamboa, F., & Prieur, C. (2014) · Journal of Statistical Computation and Simulation · doi:10.1080/00949655.2014.960415 · Cited by 112
Biehler, J., Gee, M. W., & Wall, W. A. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0618-0 · Cited by 111
A validated predictive model of coronary fractional flow reserve
Huo, Y., Svendsen, M., Choy, J. S., Zhang, Z., & Kassab, G. S. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0605 · Cited by 98
Parametric uncertainty analysis of pulse wave propagation in a model of a human arterial network
Xiu, D., & Sherwin, S. J. (2007) · Journal of Computational Physics · doi:10.1016/j.jcp.2007.05.020 · Cited by 91 · cited 1×
“In this article, we mention only the standard MC technique and the more advanced PC method, because they have been used the most in biomedical engineering [5, 14, 25, 27, 32, 33, 75].”
MethodA Mathematical Model to Evaluate Control Strategies for Mechanical Circulatory Support
Cox, L. G. E., Loerakker, S., Rutten, M. C. M., de Mol, B. A. J. M., & van de Vosse, F. N. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00755.x · Cited by 90
DESIGN UNDER UNCERTAINTY EMPLOYING STOCHASTIC EXPANSION METHODS
Eldred, M., & Elman, H. C. (2011) · International Journal for Uncertainty Quantification · doi:10.1615/int.j.uncertaintyquantification.v1.i2.20 · Cited by 89
Chin, C., Khaw, H., Luo, E., Tan, S., White, A. C., Newby, D. E., & Dweck, M. R. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.04.021 · Cited by 86 · cited 1×
“One study on the accuracy of these methods shows variations of up to 20–30 ml discrepancy between the methods [89], thus we set the standard deviation to a third of this such that samples from a normal distribution have a 99% probability of lying with 24 ml of the mean.”
MethodSimulation‐based uncertainty quantification of human arterial network hemodynamics
Chen, P., Quarteroni, A. M., & Rozza, G. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2554 · Cited by 82
Variance-Based Global Sensitivity Analysis via Sparse-Grid Interpolation and Cubature
Buzzard, G. T., & Xiu, D. (2010) · Communications in Computational Physics · doi:10.4208/cicp.230909.160310s · Cited by 59 · cited 2×
“Examples of non-intrusive global methods are the Monte Carlo (MC) method [20], the PC method [21, 22], and the Lagrangian interpolation method [23, 24].”
MethodGrid and basis adaptive polynomial chaos techniques for sensitivity and uncertainty analysis
Perkó, Z., Gilli, L., Lathouwers, D., & Kloosterman, J. L. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2013.12.025 · Cited by 57
Leguy, C. A. D., Bosboom, E. M., Gelderblom, H., Hoeks, A. P. G., & van de Vosse, F. N. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.06.010 · Cited by 56 · cited 1×
“Mathematical models have also been used to design and evaluate medical devices [6, 7], to develop training simulators for medical interventions [8], and to estimate model inputs that are impossible to measure directly [9].”
MethodHuberts, W., Donders, W. P., Delhaas, T., & van de Vosse, F. N. (2014) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2695 · Cited by 49 · cited 6×
“In this article, we mention only the standard MC technique and the more advanced PC method, because they have been used the most in biomedical engineering [5, 14, 25, 27, 32, 33, 75].”
BackgroundMethodInfluentialSelf-citationPersonalization of models with many model parameters: an efficient sensitivity analysis approach
Donders, W. P., Huberts, W., van de Vosse, F. N., & Delhaas, T. (2015) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2727 · Cited by 42 · cited 3×
“In this article, we mention only the standard MC technique and the more advanced PC method, because they have been used the most in biomedical engineering [5, 14, 25, 27, 32, 33, 75].”
BackgroundMethodSelf-citationKaragiannis, G., & Lin, G. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2013.11.016 · Cited by 37 · cited 1×
“We remark that there are alternative approaches to reduce the number of polynomial bases of the PC expansion, which are independent of the applied method to calculate the PC expansion coefficients as the adaptive ANOVA decomposition [102] or Bayesian compressive sensing methods [103].”
MethodOn the uncertainty quantification of blood flow viscosity models
Pereira, J. M. C., Moura, J. P. S. E., Ervilha, A. R., & Pereira, J. C. F. (2013) · Chemical Engineering Science · doi:10.1016/j.ces.2013.05.033 · Cited by 36
Papaioannou, T. G., Protogerou, A. D., Stergiopulos, N., Vardoulis, O., Stefanadis, C., Safar, M. E., & Blacher, J. (2014) · AGE · doi:10.1007/s11357-014-9661-0 · Cited by 31
DESIGN UNDER UNCERTAINTY EMPLOYING STOCHASTIC EXPANSION METHODS
Eldred, M. (2011) · International Journal for Uncertainty Quantification · doi:10.1615/intjuncertaintyquantification.v1.i2.20 · Cited by 29
Huberts, W., de Jonge, C. S., van der Linden, W. P. M., de Inda, M. A., Passera, K., Tordoir, J. H. M., van de Vosse, F. N., & Bosboom, E. M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.012 · Cited by 29
Self-citationHuberts, W., de Jonge, C., van der Linden, W. P. M., de Inda, M. A., Tordoir, J. H. M., van de Vosse, F. N., & Bosboom, E. M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.013 · Cited by 28
Self-citationAlternatives to the mercury sphygmomanometer
Buchanan, S. N., Orris, P., & Karliner, J. (2010) · Journal of Public Health Policy · doi:10.1057/jphp.2010.38 · Cited by 26 · cited 1×
“To assess systolic and diastolic blood pressures (ps, pd), mercury sphygmomanometers are still considered the gold standard of all non-invasive devices [87].”
BackgroundA mathematical model for simulation of early decelerations in the cardiotocogram during labor
der Jagt, M. B. V. D. H., Oei, S. G., & Bovendeerd, P. H. M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.09.004 · Cited by 24 · cited 1×
“Mathematical models have also been used to design and evaluate medical devices [6, 7], to develop training simulators for medical interventions [8], and to estimate model inputs that are impossible to measure directly [9].”
MethodStochastic sensitivity analysis for timing and amplitude of pressure waves in the arterial system
Eck, V. G., Feinberg, J., Langtangen, H. P., & Hellevik, L. R. (2015) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2711 · Cited by 23 · cited 1×
“In this article, we mention only the standard MC technique and the more advanced PC method, because they have been used the most in biomedical engineering [5, 14, 25, 27, 32, 33, 75].”
MethodSelf-citation
Metadata
- Authors
- Eck, V. G., Donders, W. P., Sturdy, J., Feinberg, J., Delhaas, T., Hellevik, L. R., & Huberts, W.
- Venue
- International Journal for Numerical Methods in Biomedical Engineering
- Publisher
- Wiley
- Published
- 2015-11-26
- Volume
- 32
- Issue
- 8
- ISSN
- 2040-7939 (ISSN-L)
- 2040-7947
- OpenAlex
- W2102724099
- Cited by
- 163
- References
- 78
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.