The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Two‐Focus Fluorescence Correlation Spectroscopy: A New Tool for Accurate and Absolute Diffusion Measurements
Abstract
We present a new method to measure absolute diffusion coefficients at nanomolar concentrations with high precision. Based on a modified fluorescence correlation spectroscopy (FCS)‐setup, this method is improved by introducing an external ruler for measuring the diffusion time by generating two laterally shifted and overlapping laser foci at a fixed and known distance. Data fitting is facilitated by a new two‐parameter model to describe the molecule detection function (MDF). We present a recorded MDF and show the excellent agreement with the fitting model. We measure the diffusion coefficient of the red fluorescent dye Atto655 under various conditions and compare these values with a value achieved by gradient pulsed field NMR (GPF NMR). From these measurements we conclude, that the new measurement scheme is robust against optical and photophysical artefacts which are inherent to standard FCS. With two‐focus‐FCS, the diffusion coefficient of 4.26×10−6 cm 2 s−1 for Atto655 in water at 25 °C compares well with the GPF NMR value of 4.28×10−6 cm 2 s−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
(1985) · Springer eBooks · doi:10.1007/978-1-4613-2389-1 · Cited by 4,856
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Investigations on the theory of the Brownian movement
Einstein, A. (1926) · BURJC Digital (King Juan Carlos University) · Cited by 1,861
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Diffusion ordered nuclear magnetic resonance spectroscopy: principles and applications
Johnson, C. S. (1999) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(99)00003-5 · Cited by 1,679
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
An Improved Diffusion-Ordered Spectroscopy Experiment Incorporating Bipolar-Gradient Pulses
Wu, D. H., Chen, A. D., & Johnson, C. S. (1995) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1995.1176 · Cited by 1,460
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Angelova, M. I., & Dimitrov, D. S. (1986) · Faraday Discussions of the Chemical Society · doi:10.1039/dc9868100303 · Cited by 1,372
Rigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
(1999) · Cited by 787
Diffusion-ordered two-dimensional nuclear magnetic resonance spectroscopy
Morris, K. F., & Johnson, C. S. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00034a071 · Cited by 730
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
Cotts, R. M., Hoch, M. J. R., Sun, T., & Markert, J. T. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90189-3 · Cited by 692
Müller, B. K., Zaychikov, E., Bräuchle, C., & Lamb, D. C. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.064766 · Cited by 568
Viscosity and Density of Aqueous Solutions of Urea and Guanidine Hydrochloride
Kawahara, K., & Tanford, C. (1966) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)96519-1 · Cited by 560
Price, W. S. (1998) · Concepts in Magnetic Resonance · doi:10.1002/(sici)1099-0534(1998)10:4<197::aid-cmr1>3.0.co;2-s · Cited by 538
Goldburg, W. I. (1999) · American Journal of Physics · doi:10.1119/1.19101 · Cited by 515
A PFG NMR experiment for accurate diffusion and flow studies in the presence of eddy currents
Gibbs, S. J., & Johnson, C. S. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90014-k · Cited by 480
Török, P., Varga, P., Laczik, Z., & Booker, G. R. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.000325 · Cited by 448
Kiefhaber, T., Rudolph, R., Kohler, H.-H., & Buchner, J. (1991) · Nature Biotechnology · doi:10.1038/nbt0991-825 · Cited by 441
Focal Volume Optics and Experimental Artifacts in Confocal Fluorescence Correlation Spectroscopy
Hess, S. T., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73990-8 · Cited by 394
Benda, A., Beneš, M., Mareček, V., Lhotský, A., Hermens, W. T., & Hof, M. (2003) · Langmuir · doi:10.1021/la0270136 · Cited by 244
Karlicek, R. F., & Lowe, I. J. (1980) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(80)90095-5 · Cited by 234
Performance of Fluorescence Correlation Spectroscopy for Measuring Diffusion and Concentration
Enderlein, J., Gregor, I., Patra, D., Dertinger, T., & Kaupp, U. B. (2005) · ChemPhysChem · doi:10.1002/cphc.200500414 · Cited by 221
Self-citationAnalysis of confocal laser-microscope optics for 3-D fluorescence correlation spectroscopy
Qian, H., & Elson, E. L. (1991) · Applied Optics · doi:10.1364/ao.30.001185 · Cited by 192
Bolinger, P.-Y., Stamou, D., & Vogel, H. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049023u · Cited by 171
Electromagnetic diffraction of light focused through a stratified medium
Török, P., & Varga, P. (1997) · Applied Optics · doi:10.1364/ao.36.002305 · Cited by 157
Brinkmeier, M., Dörre, K., Stephan, J. S., & Eigen, M. (1999) · Analytical Chemistry · doi:10.1021/ac980820i · Cited by 153
Unified operator approach for deriving Hermite–Gaussian and Laguerre–Gaussian laser modes
Enderlein, J., & Pampaloni, F. (2004) · Journal of the Optical Society of America A · doi:10.1364/josaa.21.001553 · Cited by 89
Self-citationLiu, W., Cellmer, T., Keerl, D., Prausnitz, J. M., & Blanch, H. W. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20442 · Cited by 82
Time-resolved confocal scanning device for ultrasensitive fluorescence detection
Bohmër, M., Pampaloni, F., Wahl, M., Rahn, H.-J., Erdmann, R., & Enderlein, J. (2001) · Review of Scientific Instruments · doi:10.1063/1.1406926 · Cited by 81
Self-citationExcitation saturation in two-photon fluorescence correlation spectroscopy
Berland, K. M., & Shen, G. (2003) · Applied Optics · doi:10.1364/ao.42.005566 · Cited by 69
Weljie, A. M., Yamniuk, A. P., Yoshino, H., Izumi, Y., & Vogel, H. J. (2003) · Protein Science · doi:10.1110/ps.0226203 · Cited by 57
Fluorescence correlation spectroscopy on a mirror
Rigneault, H., & Lenne, P. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.002203 · Cited by 23
Dual-Focus Fluorescence Correlation Spectroscopy
Pieper, C., Weiß, K., Gregor, I., & Enderlein, J. (2012) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/b978-0-12-388422-0.00008-x · Cited by 16
Self-citation
Cited by
A quantitative fluorescence study of protein monolayer formation on colloidal nanoparticles
Röcker, C., Pötzl, M., Zhang, F., Parak, W. J., & Nienhaus, G. U. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.195 · Cited by 730
Extreme disorder in an ultrahigh-affinity protein complex
Borgia, A., Borgia, M. B., Bugge, K., Kissling, V. M., Heidarsson, P. O., Fernandes, C. B., Sottini, A., Soranno, A., Buholzer, K. J., Nettels, D., et al. (2018) · Nature · doi:10.1038/nature25762 · Cited by 653
Precise Measurement of Diffusion Coefficients using Scanning Fluorescence Correlation Spectroscopy
Petrášek, Z., & Schwille, P. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.108811 · Cited by 493
Hofmann, H., Soranno, A., Borgia, A., Gast, K., Nettels, D., & Schuler, B. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207719109 · Cited by 479
Fluorescence correlation spectroscopy in living cells
Kim, S. A., Heinze, K. G., & Schwille, P. (2007) · Nature Methods · doi:10.1038/nmeth1104 · Cited by 444
Metadata
- Authors
- Dertinger, T., Pacheco, V., von der Hocht, I., Hartmann, R., Gregor, I., & Enderlein, J.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2007-02-08
- Volume
- 8
- Issue
- 3
- Pages
- 433-443
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W2167258646
- Cited by
- 345
- References
- 37
- FWCI
- 16.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.