Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 692

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems

Open access
Cotts, R.M, Hoch, M.J.R, Sun, T, Markert, J.T · 1989 · Journal of Magnetic Resonance (1969)

Abstract

The NMR pulsed magnetic field gradient stimulated echo technique of Tanner is especially useful for measuring the translational diffusion coefficient, D, of the resonant nucleus in materials where T1 ⪢ T2. However, in heterogeneous systems having components with dissimilar magnetic susceptibilities, a distribution of background gradients, g0, may cause excessive signal (echo) attenuation and a systematic error in the measurement of D. Three new stimulated echo sequences involving applied field gradient pulses, of amplitude ga, together with RF pulses, are described. For all of these sequences the echo attenuation and systematic error caused by g0 and g0ga terms, respectively, are greatly reduced. For one of the sequences, this reduction can be realized with gradient pulses of a single polarity. With bipolar (alternating) gradient pulses the cross term can be made to vanish, with the correct choice of conditions, for all three of the sequences. Two of the new sequences have been tested experimentally by means of D measurements involving 1H signals in bulk glycerol (homogeneous) and in granular TaH0.73 (heterogeneous) samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0022-2364(89)90189-3

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 692

Metadata

Authors
Cotts, R. M., Hoch, M. J. R., Sun, T., & Markert, J. T.
Venue
Journal of Magnetic Resonance (1969)
Publisher
Elsevier BV
Published
1989-06
Volume
83
Issue
2
Pages
252-266
ISSN
0022-2364 (ISSN-L)
OpenAlex
W2022803091
Cited by
692
References
6
FWCI
3.99
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems. https://app.cochat.ai/papers/10.1016/0022-2364(89)90189-3
The paper
Cotts, R. M., Hoch, M. J. R., Sun, T., & Markert, J. T. (1989). Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems. Journal of Magnetic Resonance (1969). https://doi.org/10.1016/0022-2364(89)90189-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.