The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Multicolor Super‐Resolution Fluorescence Imaging via Multi‐Parameter Fluorophore Detection
Open accessAbstract
Understanding the complexity of the cellular environment will benefit from the ability to unambiguously resolve multiple cellular components, simultaneously and with nanometer‐scale spatial resolution. Multicolor super‐resolution fluorescence microscopy techniques have been developed to achieve this goal, yet challenges remain in terms of the number of targets that can be simultaneously imaged and the crosstalk between color channels. Herein, we demonstrate multicolor stochastic optical reconstruction microscopy (STORM) based on a multi‐parameter detection strategy, which uses both the fluorescence activation wavelength and the emission color to discriminate between photo‐activatable fluorescent probes. First, we obtained two‐color super‐resolution images using the near‐infrared cyanine dye Alexa 750 in conjunction with a red cyanine dye Alexa 647, and quantified color crosstalk levels and image registration accuracy. Combinatorial pairing of these two switchable dyes with fluorophores which enhance photo‐activation enabled multi‐parameter detection of six different probes. Using this approach, we obtained six‐color super‐resolution fluorescence images of a model sample. The combination of multiple fluorescence detection parameters for improved fluorophore discrimination promises to substantially enhance our ability to visualize multiple cellular targets with sub‐diffraction‐limit resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Diffraction-unlimited all-optical imaging and writing with a photochromic GFP
Grotjohann, T., Testa, I., Leutenegger, M., Bock, H., Urban, N. T., Lavoie-Cardinal, F., Willig, K. I., Eggeling, C., Jakobs, S., & Hell, S. W. (2011) · Nature · doi:10.1038/nature10497 · Cited by 501
Cited by
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Self-citationSingle-cell systems biology by super-resolution imaging and combinatorial labeling
Lubeck, E., & Cai, L. (2012) · Nature Methods · doi:10.1038/nmeth.2069 · Cited by 458
Nuclear Pore Scaffold Structure Analyzed by Super-Resolution Microscopy and Particle Averaging
Szymborska, A., de Marco, A., Daigle, N., Cordes, V. C., Briggs, J. A. G., & Ellenberg, J. (2013) · Science · doi:10.1126/science.1240672 · Cited by 445
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Versatile design and synthesis of nano-barcodes
Shikha, S., Salafi, T., Cheng, J., & Zhang, Y. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00271h · Cited by 257
Metadata
- Authors
- Bates, M., Dempsey, G. T., Chen, K. H., & Zhuang, X.
- Venue
- ChemPhysChem
- Publisher
- Wiley
- Published
- 2011-12-23
- Volume
- 13
- Issue
- 1
- Pages
- 99-107
- ISSN
- 1439-4235 (ISSN-L)
- 1439-7641
- OpenAlex
- W1981475064
- Cited by
- 159
- References
- 3
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.