Static Behavior of the Respiratory System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The sections in this article are: Lung Volumes: Volume‐Pressure Relations of Respiratory System During Relaxation: Total Respiratory System: Chest Wall and Lung: Effects of Gravity and Posture: Changes Throughout Life Span: Volume‐Pressure Relations of Respiratory System During Static Muscular Efforts: Alveolar Pressure: Abdominal and Thoracic Pressures: Factors Limiting Volume Extremes: Upper Volume Extreme: Lower Volume Extreme:
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regional distribution of inspired gas in the lung.
Milic-Emili, J., Henderson, J. A., Dolovich, M. B., Trop, D., & Kaneko, K. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.3.749 · Cited by 762
Elasticity of human lungs in relation to age
Turner, J. M., Mead, J., & Wohl, M. E. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.6.664 · Cited by 524 · cited 7×
“The recoil of the lung decreases with age, particularly at high lung volume (33, 54, 97, 112, 113, 136).”
InfluentialRelationship between chest wall and pulmonary compliance and age
Mittman, C., Edelman, N. H., Norris, A. H., & Shock, N. W. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.6.1211 · Cited by 192 · cited 2×
“In fact the TLC does not decrease (107, 113, 136); a small decrease was found in some studies (97, 105,112), probably because the older subjects were smaller, as pointed out by Turner et al. (136).”
Cited by
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Chemical Control Stability in Patients with Obstructive Sleep Apnea
YOUNES, M., OSTROWSKI, M., THOMPSON, W., LESLIE, C., & SHEWCHUK, W. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2007013 · Cited by 439
The future of mechanical ventilation: lessons from the present and the past
Gattinoni, L., Marini, J. J., Collino, F., Maiolo, G., Rapetti, F., Tonetti, T., Vasques, F., & Quintel, M. (2017) · Critical Care · doi:10.1186/s13054-017-1750-x · Cited by 279
Respiratory system mechanics in sedated, paralyzed, morbidly obese patients
Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., & Gattinoni, L. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.811 · Cited by 273
Metadata
- Authors
- Agostoni, E., & Hyatt, R. E.
- Venue
- Comprehensive Physiology
- Publisher
- Wiley
- Published
- 1986-12
- Pages
- 113-130
- ISSN
- 2040-4603 (ISSN-L)
- OpenAlex
- W1607282370
- Cited by
- 152
- References
- 3
- Type
- other
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Static Behavior of the Respiratory System. https://app.cochat.ai/papers/10.1002/cphy.cp030309
- The paper
- Agostoni, E., & Hyatt, R. E. (1986). Static Behavior of the Respiratory System. Comprehensive Physiology. https://doi.org/10.1002/cphy.cp030309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.