The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Distinguishing modes of cell death using the ImageStream® multispectral imaging flow cytometer
Open accessAbstract
Background: Here we demonstrate the ability of the ImageStream® 100 Multispectral Imaging Cytometer to discriminate between live, necrotic, and early and late apoptotic cells, using unique combinations of photometric and morphometric features. Methods: Live, necrotic, and early and late apoptotic cells were prepared and analyzed by immunofluorescence microscopy, conventional flow cytometry, and imaging flow cytometry, both as single populations and as a heterogeneous mixture of cells. Results: Live (annexin V−, 7‐AAD−) and early apoptotic (annexin V+, 7‐AAD−) cells were readily identifiable using either conventional or ImageStream based flow cytometric methods. However, inspection of multispectral images of cells demonstrated that the annexin V+, 7‐AAD+ population contained both necrotic and late‐stage apoptotic cells. Although these cells could not be distinguished using conventional flow cytometric techniques, they were separable using unique combinations of photometric and morphometric measures available using ImageStream technologies. Conclusions: Using multispectral imagery, morphologically distinct cell populations can be distinguished using features not available with conventional flow cytometers. In particular, the ability to couple morphometric with photometric measures makes it possible to distinguish live cells from cells in the early phases of apoptosis, as well as late apoptotic cells from necrotic cells. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Apoptosis in the Pathogenesis and Treatment of Disease
Thompson, C. B. (1995) · Science · doi:10.1126/science.7878464 · Cited by 6,524
Death Receptors: Signaling and Modulation
Ashkenazi, A., & Dixit, V. M. (1998) · Science · doi:10.1126/science.281.5381.1305 · Cited by 5,866
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Review of snapshot spectral imaging technologies
Hagen, N., & Kudenov, M. W. (2013) · Optical Engineering · doi:10.1117/1.oe.52.9.090901 · Cited by 739
Guidelines for the use and interpretation of assays for monitoring cell death in higher eukaryotes
Galluzzi, L., Aaronson, S. A., Abrams, J., Alnemri, E. S., Andrews, D. W., Baehrecke, E. H., Bazan, N. G., Blagosklonny, M. V., Blomgren, K., Borner, C., et al. (2009) · Cell Death & Differentiation · doi:10.1038/cdd.2009.44 · Cited by 680
Intelligent Image-Activated Cell Sorting
Nitta, N., Sugimura, T., Isozaki, A., Mikami, H., Hiraki, K., Sakuma, S., Iino, T., Arai, F., Endo, T., Fujiwaki, Y., et al. (2018) · Cell · doi:10.1016/j.cell.2018.08.028 · Cited by 538
Spectral imaging: Principles and applications
Garini, Y., Young, I. T., & McNamara, G. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20311 · Cited by 482
Metadata
- Authors
- George, T. C., Basiji, D. A., Hall, B. E., Lynch, D. H., Ortyn, W. E., Perry, D. J., Seo, M. J., Zimmerman, C. A., & Morrissey, P. J.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2004-05-17
- Volume
- 59A
- Issue
- 2
- Pages
- 237-245
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W1985221982
- Cited by
- 249
- References
- 2
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.