The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Imaging flow cytometry elucidates limitations of microparticle analysis by conventional flow cytometry
Abstract
Microparticles (MPs) are submicron vesicles released from cell membranes in response to activation, cell injury, or apoptosis. The clinical importance of MPs has become increasingly recognized, although no standardized method exists for their measurement. Flow cytometry (FCM) is the most commonly used technique, however, because of the small size of MPs, and the limitations of current FCM instrumentation, accurate identification is compromised by this methodology. We decided to investigate whether the use of FCM combined with imaging, such as is possible with the ImagestreamX imaging FC (ISX), would be a more sensitive approach to characterizing MPs. Combining FCM with imaging eliminates some of the limitations demonstrated by conventional FCM, whereas also providing morphological confirmation and the ability to distinguish true single events from aggregates and cell debris. The detection limit of standard nonspecialized FCM is suboptimal when compared to ISX. Evaluating MPs below 0.200 µm and sizing remain a challenge as some MPs remain below the detection limit of ISX. Standardized calibrators, that more closely reflect the physical characteristics of MPs, need further development. © 2014 International Society for Advancement of Cytometry
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitivity measurement and compensation in spectral imaging
Ortyn, W. E., Hall, B. E., George, T. C., Frost, K., Basiji, D. A., Perry, D. J., Zimmerman, C. A., Coder, D., & Morrissey, P. J. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20306 · Cited by 115
Flow Rate Calibration for Absolute Cell Counting Rationale and Design
Walker, C., & Barnett, D. (2006) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0624s36 · Cited by 5
Cited by
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
Self-citationGurunathan, S., Kang, M.-H., Jeyaraj, M., Qasim, M., & Kim, J.-H. (2019) · Cells · doi:10.3390/cells8040307 · Cited by 1,122
Gardiner, C., Di Vizio, D., Sahoo, S., Théry, C., Witwer, K. W., Wauben, M., & Hill, A. F. (2016) · Journal of Extracellular Vesicles · doi:10.3402/jev.v5.32945 · Cited by 1,069
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
High‐speed centrifugation induces aggregation of extracellular vesicles
Linares, R., Tan, S., Gounou, C., Arraud, N., & Brisson, A. R. (2015) · Journal of Extracellular Vesicles · doi:10.3402/jev.v4.29509 · Cited by 571
Metadata
- Authors
- Erdbrügger, U., Rudy, C. K., E. Etter, M., Dryden, K. A., Yeager, M., Klibanov, A. L., & Lannigan, J.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2014-06-05
- Volume
- 85
- Issue
- 9
- Pages
- 756-770
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W1917937260
- Cited by
- 179
- References
- 2
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging flow cytometry elucidates limitations of microparticle analysis by conventional flow cytometry. https://app.cochat.ai/papers/10.1002/cyto.a.22494
- The paper
- Erdbrügger, U., Rudy, C. K., E. Etter, M., Dryden, K. A., Yeager, M., Klibanov, A. L., & Lannigan, J. (2014). Imaging flow cytometry elucidates limitations of microparticle analysis by conventional flow cytometry. Cytometry Part A. https://doi.org/10.1002/cyto.a.22494
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.