CoChat

Glucose meter inaccuracy and the impact on the care of patients

Hellman, Richard · 2012 · Diabetes/Metabolism Research and Reviews
Cited by 38

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Blood glucose testing utilizing point‐of‐care (POC) glucose meters has become increasingly common – in hospital settings, in outpatient areas, and in the self‐care of patients. It is rightly considered an essential tool for the management of diabetes. But many who rely on these meters are unaware of the pitfalls in their use and do not realize that there are settings where misleading results obtained by POC glucose meters may alter clinical decisions in the care of persons with diabetes and in some cases have caused catastrophic errors in care, even deaths. Their use in critical care settings is of great concern because many of the factors that increase the risk of inaccuracy of the POC glucose meters exist in critical care settings. Unfortunately, many clinicians are still uncritically accepting data from the POC glucose meters, to the potential detriment of the care of the patients. To improve the quality of care of those with diabetes, we need to establish better standards for the evaluation of POC glucose meters, encourage wider use of technologies that have improved the accuracy and precision of the meters, and adopt clear rules, particularly in inpatient settings, as to when to avoid using POC glucose meters and also when to verify their results before accepting the results of the POC glucose measurement. Such strategies are essential if we are to use these meters successfully. Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/dmrr.2271

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 18

  1. Hellman RH, 2011, Glucose meter accuracy and the impact on the care of diabetes in childhood and adolescence, Ped Endocrinol Rv, 8, 200
  2. Boyd JC, 2001, Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose, Clin Chem, 47, 209, 10.1093/clinchem/47.2.209 · DOI · Paper page
  3. 10.1177/193229681000400110 · DOI · Paper page
  4. 10.1016/j.jen.2008.01.008 · doi:10.1016/j.jen.2008.01.008
  5. 10.1177/193229680800200425 · DOI
  6. 10.1089/dia.2008.0034 · DOI · Paper page
  7. 10.1177/000992280003900605 · DOI
  8. ScottMG.Glucose meters – need for greater accuracy (lab perspective).Joint ADA/AACC Symposium‐Point of Care Devices for Glucose and HbA1C‐Are They up to the Task? 70th Annual ADA Scientific Sessions Orlando FL 28 June2010.
  9. 10.2337/dc06-1679 · DOI · Paper page
  10. 10.1097/01.CCM.0000189939.10881.60 · DOI · Paper page
  11. 10.1373/clinchem.2009.131318 · doi:10.1373/clinchem.2009.131318
  12. 10.1056/NEJMc090812 · DOI
  13. 10.1177/193229680900300606 · DOI · Paper page
  14. 10.1007/s00134-004-2500-5 · DOI
  15. Weitgasse R, 2007, New, small, fast acting blood glucose meters – an analytical laboratory evaluation, Swiss Med Wkly, 137, 536
  16. 10.1097/POC.0b013e318162f4da · DOI
  17. 10.1097/POC.0b13e3181a4c4f4 · DOI
  18. 10.1373/clinchem.2006.068114 · DOI

Cited by

See all 38

Metadata

Authors
Hellman, R.
Venue
Diabetes/Metabolism Research and Reviews
Publisher
Wiley
Published
2012-03
Volume
28
Issue
3
Pages
207-209
ISSN
  • 1520-7552 (ISSN-L)
  • 1520-7560
OpenAlex
W1595541430
Cited by
38
References
3
FWCI
3.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.