CoChat

Standardized Evaluation of Nine Instruments for Self-Monitoring of Blood Glucose

Kristensen, Gunn B.B., Monsen, Grete, Skeie, Svein, Sandberg, Sverre · 2008 · Diabetes Technology & Therapeutics
Cited by 56

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Instruments for self-monitoring of blood glucose (SMBG) should undergo a standardized evaluation including a user-test before being marketed. In this study the results from standardized evaluations of nine different SMBG instruments are presented, and the standardized evaluation is discussed. METHODS: Approximately 80 diabetes patients using three lots of test strips participated in each evaluation. Half of the patients were educated in how to use the meter, and the evaluations were carried out by both medical laboratory technologists (MLTs) and patients. Questionnaires were used to assess the user manual and the user-friendliness of the instrument. RESULTS: The imprecision obtained by the patients (coefficients of variation [CVs] of 3.2-8.1%) were generally higher compared to that by the MLT (CVs of 2.3-5.9%). Three of the nine instruments did not achieve the quality goal based on the recommendation in the International Organization for Standardization's ISO 15197 guideline in the hands of diabetes patients. The bias from the comparison method ranged from -10.4% to +3.2%. There were significant lot-to-lot variations and hematocrit effects for some of the instruments. Temperature difference between the instruments and the test strip caused deterioration of the quality in one instrument. The user-friendliness was in general acceptable. CONCLUSIONS: The quality of instruments for SMBG seems to have improved during recent years, although there are still analytical problems. A standardized evaluation protocol is necessary and should be regularly revised taking into account the development of new technology and the needs of the patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2008.0034

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 56

Metadata

Authors
Kristensen, G. B. B., Monsen, G., Skeie, S., & Sandberg, S.
Venue
Diabetes Technology & Therapeutics
Published
2008-12
Volume
10
Issue
6
Pages
467-477
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2077092163
Cited by
56
References
11
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardized Evaluation of Nine Instruments for Self-Monitoring of Blood Glucose. https://app.cochat.ai/papers/10.1089/dia.2008.0034
The paper
Kristensen, G. B. B., Monsen, G., Skeie, S., & Sandberg, S. (2008). Standardized Evaluation of Nine Instruments for Self-Monitoring of Blood Glucose. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2008.0034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.