Designing Meaningful Outcome Parameters Using Mobile Technology: A New Mobile Application for Telemonitoring of Patients with Heart Failure
Open accessAbstract
Aims: Health data captured by commercially available smart devices may represent meaningful patient-reported outcome measures (PROMs) in heart failure (HF) patients. The purpose of this study was to test this hypothesis by evaluating the feasibility of a new telemonitoring concept for patients following initial HF hospitalization. Methods and results: We designed a cardio patient monitoring platform (CPMP) that comprised mobile iOS-based applications for patients' smartphone/smartwatch and the equivalent application on a physicians' tablet. It allowed for safe and continuous data transmission of self-measured physiological parameters, activity data, and patient-reported symptoms. In a prospective feasibility trial with 692 patient days from 10 patients hospitalized for newly diagnosed HF with reduced ejection fraction (mean left ventricular ejection fraction (LVEF) 26.5 ± 9.8%), we examined the CPMP during the first 2 months following discharge (69 ± 15 observation days per patient). The mean daily step count recorded by the mobile devices emerged as a promising new PROM. Its 14 day average increased over the study period (3612 ± 3311 steps/day at study inclusion and 7069 ± 5006 steps/day at end of study; P < 0.0001). It is unique for continuously reflecting real-life activity and correlated significantly with traditional surrogate parameters of cardiac performance including LVEF (r = 0.44; 95% CI 0.07–0.71; P = 0.0232), 6 min walk test (r = 0.67; 95% CI 0.38–0.84; P = 0.0002), and scores in health-related quality of life questionnaires. Conclusions: We provide the first patient monitoring platform for HF patients that relies on commercially available iOS/watchOS-based devices. Our study suggests it is ready for implementation as a tool for recording meaningful PROMs in future HF trials and telemonitoring.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Administering the 6-minute walk test through a pedometer is feasible and can be used to predict HF severity and death.
“For example, one study showed that administering the 6-minute walk test through a pedometer is feasible and can be used to predict HF severity and death62.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [62]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O. D., et al. (2021) · PubMed · doi:10.1093/eurheartj/ehab670 · Cited by 19,618 · see citing works
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429 · see citing works
Clinical epidemiology of heart failure
Mosterd, A., & Hoes, A. W. (2007) · Heart · doi:10.1136/hrt.2003.025270 · Cited by 1,921 · see citing works
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804 · see citing works
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232 · see citing works
How many steps/day are enough? For older adults and special populations
Tudor-Locke, C. E., Craig, C. L., Aoyagi, Y., Bell, R. C., Croteau, K. A., Bourdeaudhuij, I. D., Ewald, B. D., Gardner, A. W., Hatano, Y., Lutes, L. D., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-80 · Cited by 1,080 · see citing works
Chen, J., Normand, S. T., Wang, Y., & Krumholz, H. M. (2011) · JAMA · doi:10.1001/jama.2011.1474 · Cited by 742 · see citing works
Koehler, F., Koehler, K., Deckwart, O., Prescher, S., Wegscheider, K., Kirwan, B.-A., Winkler, S., Vettorazzi, E., Bruch, L., Oeff, M., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31880-4 · Cited by 739 · see citing works
Koehler, F., Winkler, S., Schieber, M., Sechtem, U., Stangl, K., Böhm, M., Boll, H., Baumann, G., Honold, M., Koehler, K., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.018473 · Cited by 716 · see citing works
Inglis, S. C., Clark, R. A., McAlister, F. A., Stewart, S., & Cleland, J. G. F. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr039 · Cited by 378 · see citing works
Mobile Phone-Based Telemonitoring for Heart Failure Management: A Randomized Controlled Trial
Seto, E., Leonard, K. J., Cafazzo, J. A., Barnsley, J., Masino, C., & Ross, H. J. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1909 · Cited by 339 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Scherr, D., Kästner, P., Kollmann, A., Hallas, A., Auer, J., Krappinger, H., Schuchlenz, H. W., Stark, G., Grander, W., Jakl, G., et al. (2009) · Journal of Medical Internet Research · doi:10.2196/jmir.1252 · Cited by 279 · see citing works
Dooley, E. E., Golaszewski, N. M., & Bartholomew, J. B. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7043 · Cited by 242 · see citing works
Johnston, N., Bodegård, J., Jerström, S., Åkesson, J., Brorsson, H., Alfredsson, J., Albertsson, P., Karlsson, J., & Varenhorst, C. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.05.005 · Cited by 174 · see citing works
Behlouli, H., Feldman, D. E., Ducharme, A., Frenette, M., Giannetti, N., Grondin, F., Michel, C., Sheppard, R. J., & Pilote, L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334659 · Cited by 102 · see citing works
Zan, S., Agboola, S. O., Moore, S. A., Parks, K. A., Kvedar, J. C., & Jethwani, K. (2015) · JMIR mhealth and uhealth · doi:10.2196/mhealth.3789 · Cited by 95 · see citing works
Thorup, C. B., Hansen, J., Grønkjær, M., Andreasen, J. J., Nielsen, G. N., Sørensen, E. E., & Dinesen, B. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5191 · Cited by 87 · see citing works
Athilingam, P., Labrador, M. A., Remo, E. F. J., Mack, L., San Juan, A. B., & Elliott, A. F. (2016) · Applied Nursing Research · doi:10.1016/j.apnr.2016.07.001 · Cited by 78 · see citing works
VA FitHeart, a Mobile App for Cardiac Rehabilitation: Usability Study
Beatty, A. L., Magnusson, S. L., Fortney, J. C., Sayre, G. G., & Whooley, M. A. (2018) · JMIR Human Factors · doi:10.2196/humanfactors.8017 · Cited by 77 · see citing works
Duncan, M. J., Wunderlich, K., Zhao, Y., & Faulkner, G. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1409855 · Cited by 76 · see citing works
Daily walking performance as an independent predictor of advanced heart failure
Jehn, M., Schmidt‐Trucksäss, A., Schuster, T., Weis, M., Hanssen, H., Halle, M., & Koehler, F. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.10.006 · Cited by 75 · see citing works
Bąk, E. S., Dąbrowski, R., Piotrowicz, E., Chwyczko, T., Dobraszkiewicz-Wasilewska, B., Kowalik, I., Kazimierska, B., Jędrzejczyk, B., Smolis, R., Gepner, K., et al. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.07.041 · Cited by 70 · see citing works
Fairclough, S. J., & Ridgers, N. D. (2009) · Journal of Sports Sciences · doi:10.1080/02640410903334780 · Cited by 56 · see citing works
Telemonitoring in heart failure: Big Brother watching over you
Dierckx, R., Pellicori, P., Cleland, J. G. F., & Clark, A. L. (2014) · Heart Failure Reviews · doi:10.1007/s10741-014-9449-4 · Cited by 40 · see citing works
Domingo, M., Lupón, J., González, B., Crespo, E., López, R., Ramos, A., Urrutia, A., Pera, G., Verdú, J. M., & Bayes-Genis, A. (2012) · European Journal of Cardiovascular Nursing · doi:10.1016/j.ejcnurse.2011.02.003 · Cited by 36 · see citing works
Measured Physical Activity and 30-Day Rehospitalization in Heart Failure Patients
Waring, T., Gross, K., Soucier, R. J., & ZuWallack, R. (2016) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000204 · Cited by 35 · see citing works
Validity of the iPhone M7 motion co-processor as a pedometer for able-bodied ambulation
Major, M. J., & Alford, M. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1189086 · Cited by 29 · see citing works
Palmisano, P., Guerra, F., Ammendola, E., Ziacchi, M., Pisanò, E., Dell’Era, G., Aspromonte, V., Zaccaria, M., Ubaldo, F. D., Capucci, A., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.008146 · Cited by 28 · see citing works
mHealth and memory aids: levels of smartphone ownership in patients
Migo, E. M., Haynes, B. I., Harris, L., Friedner, K., Humphreys, K., & Kopelman, M. D. (2014) · Journal of Mental Health · doi:10.3109/09638237.2014.951479 · Cited by 27 · see citing works
Volume and Patterns of Physical Activity Across the Health and Heart Failure Continuum
Yavari, M., Haykowsky, M. J., Savu, A., Kaul, P., Dyck, J. R. B., & Haennel, R. G. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.07.005 · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
- Authors
- Werhahn, S. M., Dathe, H., Rottmann, T., Franke, T., Vahdat, D., Hasenfuß, G., & Seidler, T.
- Affiliations
- Universitätsmedizin Göttingen (DE)
- Medopad Ltd , London ,
- Corresponding author
- Seidler, Tim
- Venue
- ESC Heart Failure
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-03-13
- Volume
- 6
- Issue
- 3
- Pages
- 516-525
- ISSN
- 2055-5822 (ISSN-L)
- PMC
- PMC6487706
- OpenAlex
- W2921688314
- Cited by
- 59
- References
- 31
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 8 · 2023: 7 · 2022: 14 · 2021: 15 · 2020: 7 · 2019: 2
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- ESC Heart Failure (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion, cc-by-nc-nd)
- Funders
- Department of Cardiology of the University Medical Center Göttingen
- Topics
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- heart failure, remote patient monitoring, patient-reported outcome measures, mobile health, step count, left ventricular ejection fraction, health-related quality of life, post-discharge monitoring, wearable devices, smartwatches, 6-minute walk test
- MeSH terms
- Wearable Electronic Devices, Adult, Feasibility Studies, Female, Heart Failure, Humans, Male, Middle Aged, Prospective Studies, Quality of Life, Treatment Outcome, Telemedicine, Monitoring, Ambulatory, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review