CoChat

Carotid Body Resection for Sympathetic Modulation in Systolic Heart Failure: Results from First-In-Man Study

Open access
Niewinski, Piotr, Janczak, Dariusz, Rucinski, Artur, Tubek, Stanislaw, Engelman, Zoar J., Piesiak, Pawel, Jazwiec, Przemyslaw, Banasiak, Waldemar, Fudim, Marat, Sobotka, Paul A., Javaheri, Shahrokh, Hart, Emma C.J., Paton, Julian F.R., Ponikowski, Piotr · 2017 · European Journal of Heart Failure
Cited by 126

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Aims: Augmented reflex responses from peripheral chemoreceptors, which are mainly localized in the carotid bodies (CBs), characterize patients with systolic heart failure and contribute to adrenergic hyperactivation. We investigated whether surgical resection of CBs in these patients can be performed safely to decrease sympathetic tone. Methods and results: We studied 10 male patients with systolic heart failure (age, 59 ± 3 years; LVEF, 27 ± 7%) who underwent unilateral right-sided CB resection (four patients) or bilateral CB resection (six patients). Primary endpoints of the study were changes in muscle sympathetic nerve activity (MSNA) and peripheral chemosensitivity measured as ventilatory response to hypoxia from baseline to 1 month post-CB resection. Safety analysis included analysis of arterial blood gas and oxygenation at night through 2 months post-procedure and adverse events assessed up to 12 months. At the 1-month visit, CB resection was associated with a significant decrease both in MSNA (86.6 ± 3.1 vs. 79.7 ± 4.2 bursts/100 beats, P = 0.03) and in peripheral chemosensitivity (1.35 ± 0.19 vs. 0.41 ± 0.17 L/min/SpO2, P = 0.005). It also resulted in improved exercise tolerance. Amongst some patients with bilateral CB resection, there was a trend towards worsening of oxygen saturation at night, which in one case required therapy with non-invasive ventilation. Conclusion: We present first-in-man evidence that CB resection in patients with systolic heart failure is associated with a decrease in sympathetic activity. A bilateral procedure may carry a risk of worsening oxygenation at night. CB modulation constitutes an interesting research avenue, but careful consideration of the balance between safety and efficacy is necessary before further clinical trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ejhf.641

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 126

Metadata

Authors
Niewinski, P., Janczak, D., Rucinski, A., Tubek, S., Engelman, Z. J., Piesiak, P., Jazwiec, P., Banasiak, W., Fudim, M., Sobotka, P. A., Javaheri, S., Hart, E. C. J., Paton, J. F. R., & Ponikowski, P.
Venue
European Journal of Heart Failure
Published
2016-09-20
Volume
19
Issue
3
Pages
391-400
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W2524897358
Cited by
126
References
3
FWCI
9.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.