The DOI matches its Crossref record.
Continuous‐Flow Microreactor Chemistry under High‐Temperature/Pressure Conditions
Abstract
High‐temperature organic synthesis can be performed under continuous‐flow conditions in a stainless steel microtubular flow reactor capable of achieving temperatures of 350 °C and 200 bar. Under these extreme experimental environments transformations normally performed in a high‐boiling solvent at reflux temperature – or under sealed‐vessel microwave conditions – can be readily converted to a flow regime by using lower boiling solvents in or near their supercritical state.(© Wiley‐VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2009)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
Continuous‐Flow Technology—A Tool for the Safe Manufacturing of Active Pharmaceutical Ingredients
Gutmann, B., Cantillo, D., & Kappe, C. O. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201409318 · Cited by 1,469
Self-citationDeciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Continuous flow reactors: a perspective
Wiles, C., & Watts, P. (2012) · Green Chem. · doi:10.1039/c1gc16022b · Cited by 626
Novel Process Windows for Enabling, Accelerating, and Uplifting Flow Chemistry
Hessel, V., Kralisch, D., Kockmann, N., Noël, T., & Wang, Q. (2013) · ChemSusChem · doi:10.1002/cssc.201200766 · Cited by 596
Applying Flow Chemistry: Methods, Materials, and Multistep Synthesis
McQuade, D. T., & Seeberger, P. H. (2013) · The Journal of Organic Chemistry · doi:10.1021/jo400583m · Cited by 460
Novel Process Windows – Gate to Maximizing Process Intensification via Flow Chemistry
Hessel, V. (2009) · Chemical Engineering & Technology · doi:10.1002/ceat.200900474 · Cited by 415
Continuous Flow Synthesis. A Pharma Perspective
Malet-Sanz, L., & Susanne, F. (2012) · Journal of Medicinal Chemistry · doi:10.1021/jm2006029 · Cited by 391
Britton, J., Majumdar, S., & Weiss, G. A. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00906b · Cited by 389
Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359
A fully automated flow-based approach for accelerated peptide synthesis
Mijalis, A. J., Thomas, D. A., Simon, M. D., Adamo, A., Beaumont, R., Jensen, K. F., & Pentelute, B. L. (2017) · Nature Chemical Biology · doi:10.1038/nchembio.2318 · Cited by 329
Continuous Flow Organic Synthesis under High‐Temperature/Pressure Conditions
Razzaq, T., & Kappe, C. O. (2010) · Chemistry – An Asian Journal · doi:10.1002/asia.201000010 · Cited by 319
Self-citationRecent advances in micro reaction technology
Wiles, C., & Watts, P. (2011) · Chemical Communications · doi:10.1039/c1cc00089f · Cited by 264
Metadata
- Authors
- Razzaq, T., Glasnov, T. N., & Kappe, C. O.
- Venue
- European Journal of Organic Chemistry
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 2009
- Issue
- 9
- Pages
- 1321-1325
- ISSN
- 1099-0690 (ISSN-L)
- 1434-193X
- OpenAlex
- W1996958456
- Cited by
- 165
- References
- 0
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.