The DOI matches its Crossref record.
PROCESSIBLE POLYANILINE AS AN ADVANCED POTENTIOMETRIC pH TRANSDUCER. APPLICATION TO BIOSENSORS
Abstract
An advanced potentiometric pH transducer based on processible polyaniline (PCPAn) is reported on. Both glassy carbon and screen-printed carbon electrodes modified with PCPAn by dip-coating exhibited a fully reversible potentiometric response of approximately 90 mV/pH unit over the range from pH 3 to 9. Such a significantly higher potentiometric response of PCPAn-modified electrodes as compared with those of existing devices is explained on the basis of the thermodynamics of polyaniline redox reactions. The PCPAn-based pH transducers exhibit both good operational stability and prolonged shelf life and display a negligible response toward singly charged cations. The new thick-film pH transducer was employed for designing a potentiometric biosensor for urea. In the model solution which mimics blood serum, the urea-sensitive electrode has a detection limit of 10(-5) M urea and a maximum response of approximately 120 mV. The attractive performance characteristics are advantageous over those of existing pH sensors and offer great promise for sensing and biosensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citationShoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 343
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 277
Metadata
- Authors
- Karyakin, A. A., Vuki, M., Lukachova, L. V., Karyakina, E. E., Orlov, A. V., Karpachova, G. P., & Wang, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-05-19
- Volume
- 71
- Issue
- 13
- Pages
- 2534-2540
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980478220
- Cited by
- 159
- References
- 0
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PROCESSIBLE POLYANILINE AS AN ADVANCED POTENTIOMETRIC pH TRANSDUCER. APPLICATION TO BIOSENSORS. https://app.cochat.ai/papers/10.1021/ac981337a
- The paper
- Karyakin, A. A., Vuki, M., Lukachova, L. V., Karyakina, E. E., Orlov, A. V., Karpachova, G. P., & Wang, J. (1999). PROCESSIBLE POLYANILINE AS AN ADVANCED POTENTIOMETRIC pH TRANSDUCER. APPLICATION TO BIOSENSORS. Analytical Chemistry. https://doi.org/10.1021/ac981337a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.