A review of the immobilization of enzymes in electropolymerized films
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Polyphenol permselective membranes can be electropolymerized within an enzyme layer controllably, yielding a self-limiting thickness of 10-100 nm.
“Polyphenol permselective membranes are able to electropolymerize within an enzyme layer in a controllable manner, yielding a film with a thickness that is self-limiting (10–100 nm).”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [59]
Cites
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G. B., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,647 · see citing works
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613 · see citing works
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umaña, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588 · see citing works
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570 · see citing works
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532 · see citing works
Sasso, S. V., Pierce, R. J., Walla, R., & Yacynych, A. M. (1990) · Analytical Chemistry · doi:10.1021/ac00210a004 · Cited by 343 · see citing works
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85082-9 · Cited by 329 · see citing works
Mell, L. D., & Maloy, J. T. (1975) · Analytical Chemistry · doi:10.1021/ac60352a006 · Cited by 292 · see citing works
Rotating ring-disk enzyme electrode for surface catalysis studies
Shu, F. R., & Wilson, G. S. (1976) · Analytical Chemistry · doi:10.1021/ac50006a014 · Cited by 254 · see citing works
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85081-7 · Cited by 248 · see citing works
Charge-controllable polypyrrole/polyelectrolyte composite membranes
Shimidzu, T., Ohtani, A., Iyoda, T., & Honda, K. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85088-x · Cited by 247 · see citing works
Electrochemistry of the polypyrrole glucose oxidase electrode
Bélanger, D., Nadreau, J., & Fortier, G. (1989) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(89)87036-6 · Cited by 239 · see citing works
Enzyme microsensor for glucose with an electrochemically synthesized enzyme-polyaniline film
Shinohara, H., Chiba, T., & Aizawa, M. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)85031-5 · Cited by 229 · see citing works
Ohnuki, Y., Matsuda, H., Ohsaka, T., & Oyama, N. (1983) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(83)80338-6 · Cited by 226 · see citing works
Bruno, F., Pham, M. C., & Dubois, J. E. (1977) · Electrochimica Acta · doi:10.1016/0013-4686(77)85100-1 · Cited by 185 · see citing works
Kajiya, Y., Sugai, H., Iwakura, C., & Hiroshi Yoneyama, C. (1991) · Analytical Chemistry · doi:10.1021/ac00001a009 · Cited by 184 · see citing works
Wang, J., Chen, S., & Lin, M. S. (1989) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(89)87016-0 · Cited by 180 · see citing works
Strategies for the development of amperometric enzyme electrodes
Bartlett, P. N., & Whitaker, R. G. (1987) · Biosensors · doi:10.1016/0265-928x(87)80018-4 · Cited by 177 · see citing works
Bartlett, P. N., Tebbutt, P., & Tyrrell, C. H. (1992) · Analytical Chemistry · doi:10.1021/ac00026a008 · Cited by 167 · see citing works
Bioelectrochemical responses of the polyaniline glucose oxidase electrode
Mu, S., Huaiguo, X., & Bidong, Q. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85487-a · Cited by 150 · see citing works
Cosnier, S., & Innocent, C. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80195-a · Cited by 149 · see citing works
Peroxidase-incorporated polypyrrole membrane electrodes
Tatsuma, T., Gondaira, M., & Watanabe, T. (1992) · Analytical Chemistry · doi:10.1021/ac00034a019 · Cited by 143 · see citing works
Yabuki, S., Shinohara, H., Ikariyama, Y., & Aizawa, M. (1990) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(90)85100-j · Cited by 137 · see citing works
A new conducting polymer-coated glucose sensor
Pandey, P. C. (1988) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19888402259 · Cited by 136 · see citing works
Homogeneous ferrocene-mediated amperometric immunoassay
di Gleria, K., Green, M. J., Hill, H. A. O., & McNeil, C. J. (1986) · Analytical Chemistry · doi:10.1021/ac00297a050 · Cited by 132 · see citing works
Model of a two-substrate enzyme electrode for glucose
Leypoldt, J. K., & Gough, D. (1984) · Analytical Chemistry · doi:10.1021/ac00278a063 · Cited by 125 · see citing works
Simultaneous immobilization of glucose oxidase and a mediator in conducting polymer films
Iwakura, C., Kajiya, Y., & Hiroshi Yoneyama, C. (1988) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39880001019 · Cited by 117 · see citing works
Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films
Witkowski, A., Freund, M. S., & Brajter‐Toth, A. (1991) · Analytical Chemistry · doi:10.1021/ac00006a013 · Cited by 116 · see citing works
An Overview of Phenol Electropolymerization for Metal Protection
Mengoli, G., & Musiani, M. M. (1987) · Journal of The Electrochemical Society · doi:10.1149/1.2100379 · Cited by 113 · see citing works
Bartlett, P. N., & Caruana, D. J. (1992) · The Analyst · doi:10.1039/an9921701287 · Cited by 109 · see citing works
Covalent electropolymerization of glucose oxidase in polypyrrole
Wolowacz, S. E., Hin, B. F. Y. Y., & Lowe, C. R. (1992) · Analytical Chemistry · doi:10.1021/ac00038a008 · Cited by 109 · see citing works
du Poët, P. D. T., Miyamoto, S., Murakami, T., Kimura, J., & Karube, I. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82082-6 · Cited by 108 · see citing works
Dicks, J. M., Aston, W. J., Davis, G. B., & Turner, A. P. F. (1986) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82441-1 · Cited by 107 · see citing works
Electrochemical response of an enzyme-loaded polyaniline film
Cooper, J. C., & Hall, E. A. H. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)80004-u · Cited by 100 · see citing works
Self-citationCentonze, D., Guerrieri, A., Malitesta, C., Palmisano, F., & Zambonin, P. G. (1992) · Analytical and Bioanalytical Chemistry · doi:10.1007/bf00321865 · Cited by 97 · see citing works
pH response of platinum and vitreous carbon electrodes modified by electropolymerized films
Cheek, G. T., Wales, C. P., & Nowak, R. (1983) · Analytical Chemistry · doi:10.1021/ac00253a047 · Cited by 92 · see citing works
Quinone-mediated glucose oxidase electrode with the enzyme immobilized in polypyrrole
Janda, P., & Weber, J. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85388-6 · Cited by 92 · see citing works
Rostad, C. E., Pereira, W. E., & Ratcliff, S. M. (1984) · Analytical Chemistry · doi:10.1021/ac00278a052 · Cited by 90 · see citing works
Electro-conductive enzyme membrane
Yabuki, S., Shinohara, H., & Aizawa, M. (1989) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39890000945 · Cited by 88 · see citing works
Conducting polypyrrole electrochemically prepared from aqueous solutions
Qian, R., Qiu, J., & Shen, D. (1987) · Synthetic Metals · doi:10.1016/0379-6779(87)90846-0 · Cited by 83 · see citing works
Enzyme switch responsive to glucose
Bartlett, P. N., & Birkin, P. R. (1993) · Analytical Chemistry · doi:10.1021/ac00056a029 · Cited by 83 · see citing works
Koopal, C. G. J., de Ruiter, B., & Nolte, R. J. M. (1991) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39910001691 · Cited by 80 · see citing works
Glucose sensor utilizing polypyrrole incorporated in tract-etch membranes as the mediator
Koopal, C. G. J., Feiters, M. C., Nolte, R. J. M., de Ruiter, B., & Schasfoort, R. B. M. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)80003-t · Cited by 77 · see citing works
Deshpande, M. V., & Hall, E. A. H. (1990) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(90)80033-a · Cited by 69 · see citing works
Khan, G. F., Kobatake, E., Shinohara, H., Ikariyama, Y., & Aizawa, M. (1992) · Analytical Chemistry · doi:10.1021/ac00035a011 · Cited by 68 · see citing works
Matsue, T., Kasai, N., Narumi, M., Nishizawa, M., Yamada, H., & Uchida, I. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85387-5 · Cited by 65 · see citing works
Electrochemical Fabrication of Amperometric Microenzyme Sensor
Ikariyama, Y., Yamauchi, S., Yukiashi, T., & Ushioda, H. (1989) · Journal of The Electrochemical Society · doi:10.1149/1.2096713 · Cited by 65 · see citing works
Sun, Z., & Tachikawa, H. (1992) · Analytical Chemistry · doi:10.1021/ac00034a008 · Cited by 63 · see citing works
Bartlett, P. N., Ali, Z., & Eastwick‐Field, V. (1992) · Journal of the Chemical Society Faraday Transactions · doi:10.1039/ft9928802677 · Cited by 62 · see citing works
Kajiya, Y., Tsuda, R., & Hiroshi Yoneyama, C. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85466-3 · Cited by 61 · see citing works
An enzyme switch sensitive to NADH
Matsue, T., Nishizawa, M., Sawaguchi, T., & Uchida, I. (1991) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39910001029 · Cited by 57 · see citing works
Bioelectrochemical responses of the polyaniline uricase electrode
Shaolin, M., Jinqing, K., & Jian-bing, Z. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80565-l · Cited by 56 · see citing works
Model analysis of enzyme monolayer- and bilayer-modified electrodes: the steady-state response
Tatsuma, T., & Watanabe, T. (1992) · Analytical Chemistry · doi:10.1021/ac00030a010 · Cited by 54 · see citing works
Electrochemical glucose sensors on permselective non-conducting substituted pyrrole polymers
Schalkhammer, T. G. M., Mann-Buxbaum, E., Pittner, F., & Urban, G. A. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)80122-z · Cited by 48 · see citing works
Matsue, T., Yamada, H., Chang, H., Uchida, I., Nagata, K., & Tomita, K. (1990) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/0167-4838(90)90006-2 · Cited by 46 · see citing works
Permselectivity of films prepared by electropolymerization of 2,6-dimethylphenol
Ohsaka, T., Hirokawa, T., Miyamoto, H., & Oyama, N. (1987) · Analytical Chemistry · doi:10.1021/ac00141a004 · Cited by 46 · see citing works
A polypyrrole [RhIIIC5Me5(bpy)Cl]+ modified electrode for the reduction of NAD+ cofactor
Cosnier, S., & Gunther, H. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)80079-6 · Cited by 42 · see citing works
Electrochemical polymerization of pyrrole in aqueous buffer solutions
Pei, Q., & Qian, R. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80073-d · Cited by 39 · see citing works
Yabuki, S., Fumio, M., & Asai, M. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85017-q · Cited by 34 · see citing works
Kajiya, Y., Matsumoto, H., & Hiroshi Yoneyama, C. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)87077-h · Cited by 34 · see citing works
Schuhmann, W. W., & Kittsteiner-Eberle, R. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)80012-m · Cited by 30 · see citing works
Ferrocene-Mediated Enzyme Electrode for Glucose with the Use of Conducting Polymer Support
Mizutani, F., & Asai, M. (1988) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.61.4458 · Cited by 30 · see citing works
Electrochemical biosensors on thin-film metals and conducting polymers
Schalkhammer, T. G. M., Mann-Buxbaum, E., Urban, G. A., & Pittner, F. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)93770-7 · Cited by 30 · see citing works
Gunasingham, H., & Tan, C. (1989) · Electroanalysis · doi:10.1002/elan.1140010306 · Cited by 25 · see citing works
Bélanger, D., Brassard, E., & Fortier, G. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80510-3 · Cited by 24 · see citing works
Electrical Conductivity of Polypyrrole Films Doped with Carboxylate Anions
Kuwabata, S., Nakamura, J., & Hiroshi Yoneyama, C. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2086801 · Cited by 22 · see citing works
Pickett, C. J., Ryder, K. S., & Moutet, J. (1992) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39920000694 · Cited by 21 · see citing works
Martin, C. R., Dyke, L. S. V., & Cai, Z. (1992) · Electrochimica Acta · doi:10.1016/0013-4686(92)80121-2 · Cited by 19 · see citing works
Scanning tunneling microscopy of polypyrrole glucose oxidase electrodes
Yaniv, D. R., McCormick, L. D., Wang, J., & Naser, N. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85450-4 · Cited by 18 · see citing works
Graphite furnace vaporization with laser-enhanced ionization detection
Smith, B. W., Petrucci, G. A., Badini, R. G., & Winefordner, J. D. (1993) · Analytical Chemistry · doi:10.1021/ac00050a005 · Cited by 16 · see citing works
Dubinin, A. G., Li, F., Li, Y., & Yu, J. (1991) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(91)87025-c · Cited by 14 · see citing works
Cosnier, S., & Innocent, C. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80432-4 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,661 · see citing works
Potential of Different Enzyme Immobilization Strategies to Improve Enzyme Performance
Garcia‐Galan, C., Berenguer‐Murcia, Á., Fernández‐Lafuente, R., & Rodrigues, R. C. (2011) · Advanced Synthesis & Catalysis · doi:10.1002/adsc.201100534 · Cited by 1,617 · see citing works
Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 980 · see citing works
Electrochemistry of Poly(3,4‐alkylenedioxythiophene) Derivatives
Groenendaal, L., Zotti, G., Aubert, P., Waybright, S. M., & Reynolds, J. R. (2003) · Advanced Materials · doi:10.1002/adma.200300376 · Cited by 943 · see citing works
Multifunctional 3D nanoarchitectures for energy storage and conversion
Rolison, D. R., Long, J. W., Lytle, J. C., Fischer, A. E., Rhodes, C. P., McEvoy, T. M., Bourg, M., & Lubers, A. M. (2008) · Chemical Society Reviews · doi:10.1039/b801151f · Cited by 812 · see citing works
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 769 · see citing works
Biosensors based on carbon nanotubes
Balasubramanian, K., & Burghard, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0314-8 · Cited by 726 · see citing works
Conducting polymer nanomaterials: electrosynthesis and applications
Li, C., Bai, H., & Shi, G. (2009) · Chemical Society Reviews · doi:10.1039/b816681c · Cited by 687 · see citing works
Applications of conducting polymer composites to electrochemical sensors: A review
Naveen, M. H., Gurudatt, N. G., & Shim, Y. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.09.001 · Cited by 539 · see citing works
Biomolecular immobilization on conducting polymers for biosensing applications
Ahuja, T., Mir, I. A., Kumar, D., & Rajesh, R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.046 · Cited by 503 · see citing works
Electrochemical Sensors Based on Organic Conjugated Polymers
Rahman, M. A., Kumar, P., Park, D., & Shim, Y. (2008) · Sensors · doi:10.3390/s8010118 · Cited by 465 · see citing works
Recent developments in faradaic bioelectrochemistry
Armstrong, F. A., & Wilson, G. S. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00342-x · Cited by 446 · see citing works
Pud, A. A., Ogurtsov, N. A., Korzhenko, A., & Shapoval, G. S. (2003) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2003.08.001 · Cited by 429 · see citing works
Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes
Bobacka, J. (2005) · Electroanalysis · doi:10.1002/elan.200503384 · Cited by 423 · see citing works
Immobilization of bio-macromolecules on self-assembled monolayers: methods and sensor applications
Samanta, D., & Sarkar, A. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00056f · Cited by 416 · see citing works
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Jelinek, R., & Kolusheva, S. (2004) · Chemical Reviews · doi:10.1021/cr0300284 · Cited by 337 · see citing works
Pernaut, J.-M., & Reynolds, J. R. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp994274o · Cited by 293 · see citing works
Wearable Bioelectronics: Enzyme-Based Body-Worn Electronic Devices
Kim, J., Jeerapan, I., Sempionatto, J. R., Barfidokht, A., Mishra, R. K., Campbell, A. S., Hubble, L. J., & Wang, J. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00451 · Cited by 290 · see citing works
Recent advances in carbon nanotube based electrochemical biosensors
Gupta, S., Murthy, C. N., & Prabha, C. R. (2017) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.038 · Cited by 279 · see citing works
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 278 · see citing works
Prospects of conducting polymers in molecular electronics
Saxena, V., & Malhotra, B. D. (2003) · Current Applied Physics · doi:10.1016/s1567-1739(02)00217-1 · Cited by 272 · see citing works
Holland, J. T., Lau, C., Brozik, S. M., Atanassov, P. B., & Banta, S. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2071237 · Cited by 266 · see citing works
Carbon-nanotubes doped polypyrrole glucose biosensor
Wang, J., & Musameh, M. M. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.02.059 · Cited by 260 · see citing works
Biosensors based on electropolymerized films: new trends
Cosnier, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2131-7 · Cited by 259 · see citing works
Collings, A. F., & Caruso, F. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/11/005 · Cited by 258 · see citing works
Structured thin films as functional components within biosensors
Davis, F., & Higson, S. P. J. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.001 · Cited by 190 · see citing works
A review on impedimetric immunosensors for pathogen and biomarker detection
Leva-Bueno, J., Peyman, S. A., & Millner, P. A. (2020) · Medical Microbiology and Immunology · doi:10.1007/s00430-020-00668-0 · Cited by 186 · see citing works
Polypyrrole-hydrogel composites for the construction of clinically important biosensors
Brahim, S. I., Narinesingh, D., & Guiseppi‐Elie, A. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00262-7 · Cited by 185 · see citing works
Conducting polymer based amperometric enzyme electrodes
Schuhmann, W. W. (1995) · Microchimica Acta · doi:10.1007/bf01248237 · Cited by 179 · see citing works
Electrochemical synthesis of polypyrrole films over each of well-aligned carbon nanotubes
Chen, J. H., Huang, Z., Wang, D. Z., Yang, S.-Y., Li, W. Z., Wen, J., & Ren, Z. (2001) · Synthetic Metals · doi:10.1016/s0379-6779(01)00404-0 · Cited by 173 · see citing works
Cholesterol biosensors prepared by layer-by-layer technique
Ram, M. K., Bertoncello, P., Ding, H., Paddeu, S., & Nicolini, C. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00208-1 · Cited by 166 · see citing works
Schuhmann, W. W. (2002) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00058-7 · Cited by 166 · see citing works
Garjonytė, R., & Malinauskas, A. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00101-9 · Cited by 165 · see citing works
Vidal, J. C., García-Ruiz, E., & Castillo, J. R. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00838-1 · Cited by 165 · see citing works
Bartlett, P. N., & Pratt, K. F. E. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04236-7 · Cited by 164 · see citing works
Electroanalysis and Biosensors
Wang, J. (1999) · Analytical Chemistry · doi:10.1021/a1999905e · Cited by 159 · see citing works
Affinity Biosensors Based on Electropolymerized Films
Cosnier, S. (2005) · Electroanalysis · doi:10.1002/elan.200503308 · Cited by 157 · see citing works
Choi, S.-J., & Park, S. (2002) · Journal of The Electrochemical Society · doi:10.1149/1.1432675 · Cited by 157 · see citing works
Jeykumari, D. R. S., Ramaprabhu, S., & Narayanan, S. S. (2007) · Carbon · doi:10.1016/j.carbon.2007.01.006 · Cited by 157 · see citing works
Enzyme-mediated amperometric biosensors prepared with the Layer-by-Layer (LbL) adsorption technique
Ferreira, M., Fiorito, P. A., Oliveira, O. N., & de Torresi, S. I. C. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.12.025 · Cited by 153 · see citing works
Cosnier, S., Senillou, A., Grätzel, M., Comte, P., Vlachopoulos, N., Jaffrezic-Renault, N. J., & Martelet, C. (1999) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(99)00223-5 · Cited by 148 · see citing works
A three-enzyme microelectrode sensor for detecting purine release from central nervous system
Llaudet, E., Botting, N. P., Crayston, J. A., & Dale, N. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00106-9 · Cited by 145 · see citing works
Sundramoorthy, A. K., & Chen, S. (2008) · Sensors · doi:10.3390/s8020739 · Cited by 142 · see citing works
Palmisano, F., Rizzi, R., Centonze, D., & Zambonin, P. G. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00107-x · Cited by 138 · see citing works
Developments and applications of biosensors in food analysis
Luong, J. H. T., Bouvrette, P., & Male, K. B. (1997) · Trends in biotechnology · doi:10.1016/s0167-7799(97)01071-8 · Cited by 136 · see citing works
Listening to the brain: microelectrode biosensors for neurochemicals
Dale, N., Hatz, S., Tian, F., & Llaudet, E. (2005) · Trends in biotechnology · doi:10.1016/j.tibtech.2005.05.010 · Cited by 135 · see citing works
Electrochemical quartz crystal microbalance investigation of surface fouling due to phenol oxidation
Wang, J., Jiang, M., & Lü, F. (1998) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00583-4 · Cited by 133 · see citing works
Enzyme-modified electrodes for biosensors and biofuel cells
Pinyou, P., Blay, V., Mureşan, L. M., & Noguer, T. (2019) · Materials Horizons · doi:10.1039/c9mh00013e · Cited by 132 · see citing works
Ou, Y., Buchanan, A. M., Witt, C. E., & Hashemi, P. (2019) · Analytical Methods · doi:10.1039/c9ay00055k · Cited by 130 · see citing works
Pulse technique for the electrochemical deposition of polymer films on electrode surfaces
Schuhmann, W. W., Kranz, C., Wohlschläger, H., & Strohmeier, J. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00086-9 · Cited by 127 · see citing works
Interface analysis in biosensor design
Göpel†, W., & Heiduschka, P. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99225-a · Cited by 123 · see citing works
Palmisano, F., Zambonin, P. G., Centonze, D., & Quinto, M. (2002) · Analytical Chemistry · doi:10.1021/ac0258608 · Cited by 117 · see citing works
Nien, P., Tung, T., & Ho, K. (2006) · Electroanalysis · doi:10.1002/elan.200603552 · Cited by 116 · see citing works
Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors
Miao, Y., Jianrong, C., & Wu, X. (2004) · Trends in biotechnology · doi:10.1016/j.tibtech.2004.03.004 · Cited by 115 · see citing works
Hiller, M., Kranz, C., Huber, J., Bäuerle, P., & Schuhmann, W. W. (1996) · Advanced Materials · doi:10.1002/adma.19960080306 · Cited by 115 · see citing works
Iwuoha, E. I., de Villaverde, D. S., Garcia, N. P., Smyth, M. R., & Pingarrón, J. M. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00042-0 · Cited by 110 · see citing works
Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline
Zhou, H., Chen, H., Luo, S., Chen, J., Wei, W., & Kuang, Y. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.04.024 · Cited by 109 · see citing works
Ram, M. K., Adami, M., Paddeu, S., & Nicolini, C. A. (2000) · Nanotechnology · doi:10.1088/0957-4484/11/2/312 · Cited by 108 · see citing works
Huang, L., Luo, G., Zhao, X., Chen, J., & Cao, W. (2000) · Journal of Applied Polymer Science · doi:10.1002/1097-4628(20001017)78:3 · Cited by 12 · see citing works
Biosensors based on oxidases immobilized in various conducting polymers
Trojanowicz, M., Geschke, O., Krawczyk, T. K. V., & Cammann, K. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)01724-0 · Cited by 108 · see citing works
Uang, Y., & Chou, T. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00168-4 · Cited by 104 · see citing works
Electrochemical catalysis with redox polymer and polyion–protein films
Rusling, J. F., & Forster, R. J. (2003) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(03)00148-6 · Cited by 103 · see citing works
Electrochemical Enzyme Biosensors Revisited: Old Solutions for New Problems
Monteiro, T., & Almeida, M. G. (2018) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2018.1461552 · Cited by 101 · see citing works
Rubianes, M. D., & Rivas, G. A. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01059-5 · Cited by 100 · see citing works
Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing
Lillie, G. C., Payne, P. A., & Vadgama, P. M. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00821-8 · Cited by 100 · see citing works
Electrochemical biosensors based on enzymes immobilized in electropolymerized films
Trojanowicz, M., & Krawczyk, T. K. V. (1995) · Microchimica Acta · doi:10.1007/bf01248249 · Cited by 100 · see citing works
Wang, J., Myung, N. V., Yun, M., & Monbouquette, H. G. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.08.023 · Cited by 99 · see citing works
Electrodeposited polytyramine as an immobilisation matrix for enzyme biosensors
Situmorang, M., Gooding, J. J., Hibbert, D. B., & Barnett, D. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00033-5 · Cited by 98 · see citing works
Glucose microbiosensor based on alumina sol–gel matrix/electropolymerized composite membrane
Chen, X., Hu, Y., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00093-3 · Cited by 95 · see citing works
Adeloju, S. B. O., & Moline, A. N. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00117-2 · Cited by 95 · see citing works
Ribeiro, J. A., Pereira, C. M. D. M., Silva, F., & Sales, M. G. F. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.017 · Cited by 93 · see citing works
Guerrieri, A., Benedetto, G. E. D., Palmisano, F., & Zambonin, P. G. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00064-x · Cited by 93 · see citing works
Pan, D., Chen, J., Yao, S., Tao, W., & Nie, L. (2005) · Analytical Sciences · doi:10.2116/analsci.21.367 · Cited by 91 · see citing works
Behavior of metal ions in bioelectrochemical systems: A review
Lu, Z., Chang, D., Ma, J., Huang, G., Cai, L., & Zhang, L. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.10.168 · Cited by 91 · see citing works
Conjugated Polymer Inverse Opals for Potentiometric Biosensing
Cassagneau, T. P., & Caruso, F. (2002) · Advanced Materials · doi:10.1002/adma.200290014 · Cited by 90 · see citing works
Carbon post-microarrays for glucose sensors
Xu, H., Malladi, K., Wang, C., Kulinsky, L., Song, M., & Madou, M. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.01.031 · Cited by 87 · see citing works
Kranz, C., Kueng, A., Lugstein, A., Bertagnolli, E., & Mizaikoff, B. (2004) · Ultramicroscopy · doi:10.1016/j.ultramic.2003.10.004 · Cited by 87 · see citing works
Biosensors Based on Immobilization of Biomolecules by Electrogenerated Polymer Films
Cosnier, S. (2000) · Applied Biochemistry and Biotechnology · doi:10.1385/abab:89:2-3:127 · Cited by 86 · see citing works
Borgmann, S., Schulte, A., Neugebauer, S., & Schuhmann, W. W. (2011) · Advances in electrochemical science and engineering · doi:10.1002/9783527644117.ch1 · Cited by 86 · see citing works
Coche‐Guérente, L., Cosnier, S., Innocent, C., & Mailley, P. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00178-3 · Cited by 84 · see citing works
A Glucose Sensor Made of an Enzymatic Clay-Modified Electrode and Methyl Viologen Mediator
Zen, J., & Lo, C.-W. (1996) · Analytical Chemistry · doi:10.1021/ac960090j · Cited by 84 · see citing works
Garjonytė, R., & Malinauskas, A. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00317-8 · Cited by 84 · see citing works
Stoica, L., Dimcheva, N. D., Ackermann, Y., Karnicka, K., Guschin, D. A., Kulesza, P. J., Rogalski, J., Haltrich, D., Ludwig, R., Gorton, L., et al. (2009) · Fuel Cells · doi:10.1002/fuce.200800033 · Cited by 83 · see citing works
Xiao, Y., Ju, H., & Chen, H.-Y. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00254-8 · Cited by 82 · see citing works
Vidal, J.-C., García-Ruiz, E., & Castillo, J. R. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00116-4 · Cited by 81 · see citing works
Enzyme‐modified microelectrodes for in vivo neurochemical measurements
Pantano, P., & Kuhr, W. G. (1995) · Electroanalysis · doi:10.1002/elan.1140070502 · Cited by 81 · see citing works
Piro, B., Dang, L. A., Pham, M., Fabiano, S. N., & Tran‐Minh, C. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(01)00595-2 · Cited by 80 · see citing works
Akkermans, R. P., Wu, M., & Compton, R. G. (1998) · Electroanalysis · doi:10.1002/(sici)1521-4109(199809)10:12 · Cited by 33 · see citing works
Susanto, H., Samsudin, A. M., Rokhati, N., & Widiasa, I. N. (2013) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2013.02.005 · Cited by 77 · see citing works
Wheeldon, I. R., Gallaway, J. W., Barton, S. C., & Banta, S. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805249105 · Cited by 77 · see citing works
Sasso, L., Heiskanen, A. R., Diazzi, F., Dimaki, M., Castillo-León, J., Vergani, M., Landini, E., Raiteri, R., Ferrari, G., Carminati, M., et al. (2013) · The Analyst · doi:10.1039/c3an00085k · Cited by 77 · see citing works
Concentric glucose/O2 biofuel cell
Habrioux, A., Merle, G. E., Servat, K., Kokoh, K. B., Innocent, C., Cretin, M., & Tingry, S. (2008) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2008.05.011 · Cited by 76 · see citing works
Dopamine voltammetry at overoxidised polyindole electrodes
Ghita, M., & Arrigan, D. W. M. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2004.05.030 · Cited by 75 · see citing works
A scanning force microscopy study of poly(phenol) films containing immobilized glucose oxidase
Arrigan, D. W. M., & Bartlett, P. N. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00132-2 · Cited by 74 · see citing works
Majidi, M. R., Jouyban, A., & Asadpour‐Zeynali, K. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.04.019 · Cited by 74 · see citing works
Cosnier, S., Galland, B., & Innocent, C. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00207-6 · Cited by 74 · see citing works
Electrochemical Polymerization
Fomo, G., Waryo, T., Feleni, U., Baker, P., & Iwuoha, E. I. (2019) · Polymers and polymeric composites · doi:10.1007/978-3-319-95987-0_3 · Cited by 73 · see citing works
An electroenzymatic l-glutamate microbiosensor selective against dopamine
Hamdi, N., Wang, J., Walker, E., Maidment, N. T., & Monbouquette, H. G. (2006) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2006.03.022 · Cited by 73 · see citing works
Morshed, M. N., Behary, N., Bouazizi, N., Guan, J.-P., Chen, G., & Nierstrasz, V. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-52087-8 · Cited by 73 · see citing works
- Authors
- Barlett, P. N., & Cooper, J. M.
- Affiliations
- University of Southampton (GB)
- University of Glasgow (GB)
- ORCID
- Cooper, J.M.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 1993-12
- Volume
- 362
- Issue
- 1-2
- Pages
- 1-12
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W1987410104
- Cited by
- 472
- References
- 72
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 6 · 2016: 12 · 2015: 8 · 2014: 16 · 2013: 22 · 2012: 11
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Electroanalytical Chemistry (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- enzyme immobilization, electropolymerization, conducting polymer films, electrode surface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review