Amperometric Detection of Catecholamine Neurotransmitters Using Electrocatalytic Substrate Recycling at a Laccase Electrode
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An enzyme electrode based on the coimmobilization of an osmium redox polymer and laccase on glassy carbon electrodes has been applied to ultra sensitive amperometric detection of the catecholamine neurotransmitters dopamine, epinephrine and norepinephrine, resulting in nanomolar detection limits, as low as 4 nM for dopamine. The sensitivity of the electrode is due to signal amplification via oxidation of the catecholamine by the immobilized laccase, which is regenerated by concomitant reduction of oxygen to water, coupled to the electrocatalytic re‐reduction of the oxidized catecholamine by the osmium redox complex: electrocatalytic substrate recycling. In addition because the sensor can be operated in reductive mode at −0.2 V (vs. Ag/AgCl), noise and interferences are diminished. Combined with its high sensitivity this enzyme electrode also exhibited excellent selectivity allowing the detection of catecholamines in the presence of ascorbic acid. However, differentiation between the current responses achieved for the three catecholamines is not possible. The effective mode of constant recycling, resulting in amplification of the current response, of the laccase enzyme electrode sensor combined with the inherent advantages of using electrochemical techniques holds great promise for the future of catecholamine detection and monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best?
Lenders, J. W. M., Pacak, K., Walther, M. M., Linehan, W. M., Mannelli, M., Friberg, P., Keiser, H. R., Goldstein, D. S., & Eisenhofer, G. (2002) · JAMA · doi:10.1001/jama.287.11.1427 · Cited by 1,134
Cited by
Industrial and biotechnological applications of laccases: A review
Rodríguez Couto, S., & Toca Herrera, J. L. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2006.04.003 · Cited by 1,296
Laccase-based biosensors for detection of phenolic compounds
Rodríguez-Delgado, M. M., Alemán-Nava, G. S., Rodríguez-Delgado, J. M., Dieck-Assad, G., Martínez-Chapa, S. O., Barceló, D., & Parra, R. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.05.008 · Cited by 302
Bioprospecting and biotechnological applications of fungal laccase
Upadhyay, P., Shrivastava, R., & Agrawal, P. K. (2016) · 3 Biotech · doi:10.1007/s13205-015-0316-3 · Cited by 242
Laccase from prokaryotes: a new source for an old enzyme
Singh, G., Bhalla, A., Kaur, P., Capalash, N., & Sharma, P. (2011) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-011-9257-4 · Cited by 158
Lignin‐Degrading Enzymes: An Overview
Hatti‐Kaul, R., & Ibrahim, V. (2013) · Bioprocessing Technologies in Biorefinery for Sustainable Production of Fuels, Chemicals, and Polymers · doi:10.1002/9781118642047.ch10 · Cited by 25
Metadata
- Authors
- Ferry, Y., & Leech, D.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-01-28
- Volume
- 17
- Issue
- 2
- Pages
- 113-119
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2128910374
- Cited by
- 64
- References
- 1
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.