CoChat

Amperometric Detection of Catecholamine Neurotransmitters Using Electrocatalytic Substrate Recycling at a Laccase Electrode

Ferry, Yvonne, Leech, Dónal · 2005 · Electroanalysis
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An enzyme electrode based on the coimmobilization of an osmium redox polymer and laccase on glassy carbon electrodes has been applied to ultra sensitive amperometric detection of the catecholamine neurotransmitters dopamine, epinephrine and norepinephrine, resulting in nanomolar detection limits, as low as 4 nM for dopamine. The sensitivity of the electrode is due to signal amplification via oxidation of the catecholamine by the immobilized laccase, which is regenerated by concomitant reduction of oxygen to water, coupled to the electrocatalytic re‐reduction of the oxidized catecholamine by the osmium redox complex: electrocatalytic substrate recycling. In addition because the sensor can be operated in reductive mode at −0.2 V (vs. Ag/AgCl), noise and interferences are diminished. Combined with its high sensitivity this enzyme electrode also exhibited excellent selectivity allowing the detection of catecholamines in the presence of ascorbic acid. However, differentiation between the current responses achieved for the three catecholamines is not possible. The effective mode of constant recycling, resulting in amplification of the current response, of the laccase enzyme electrode sensor combined with the inherent advantages of using electrochemical techniques holds great promise for the future of catecholamine detection and monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.200403069

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Ferry, Y., & Leech, D.
Venue
Electroanalysis
Publisher
Wiley
Published
2005-01-28
Volume
17
Issue
2
Pages
113-119
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W2128910374
Cited by
64
References
1
FWCI
1.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.