The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Sample application by in‐gel rehydration improves the resolution of two‐dimensional electrophoresis with immobilized pH gradients in the first dimension
Abstract
We describe a modification in the sample application mode for isoelectric focusing with immobilized pH gradients. Instead of being applied at the surface of the gel in a sample cup, the sample is introduced into the gel during the immobilized pH gradient strip rehydration step. This modification implies the use of low percentage gels (below 3.5%T) and specially designed, but simple, rehydration chambers. The main advantages are a uniform resolution without side effects and the possibility of handling large sample volumes (500 μL for a standard 3 × 160 × 0.5 mm strip), allowing micropreparative work (milligram samples) with a simple experimental design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schägger, H., & von Jagow, G. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90587-2 · Cited by 11,444
Matsudaira, P. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)61070-1 · Cited by 4,950
Rosenfeld, J., Capdevielle, J., Guillemot, J. C., & Ferrara, P. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90061-b · Cited by 1,239
Bjellqvist, B., Hughes, G. J., Pasquali, C., Paquet, N., Ravier, F., Sanchez, J., Frutiger, S., & Hochstrasser, D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.11501401163 · Cited by 1,014
Görg, A., Postel, W., & Günther, S. (1988) · ELECTROPHORESIS · doi:10.1002/elps.1150090913 · Cited by 777
Methods for increasing the resolution of two-dimensional protein electrophoresis
Hochstrasser, D. F., Harrington, M. G., Hochstrasser, A.-C., Miller, M. J., & Merril, C. R. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90209-6 · Cited by 636
Ramagli, L. S., & Rodriguez, L. V. (1985) · ELECTROPHORESIS · doi:10.1002/elps.1150061109 · Cited by 490
Immobilized pH Gradients: Theory and Methodology
(1990) · Laboratory Techniques in Biochemistry and Molecular Biology · doi:10.1016/s0075-7535(08)x7006-8 · Cited by 353
Görg, A., Postel, W., Weser, J., Günther, S., Strahler, J. R., Hanash, S. M., & Somerlot, L. (1987) · ELECTROPHORESIS · doi:10.1002/elps.1150080207 · Cited by 269
A comparison between low background silver diammine and silver nitrate protein stains
Rabilloud, T. (1992) · ELECTROPHORESIS · doi:10.1002/elps.1150130190 · Cited by 267
Self-citationBjellqvist, B., Sanchez, J., Pasquali, C., Ravier, F., Paquet, N., Frutiger, S., Hughes, G. J., & Hochstrasser, D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.11501401212 · Cited by 187
Wiltfang, J., Arold, N., & NEUHOFF, V. (1991) · Electrophoresis · doi:10.1002/elps.1150120507 · Cited by 99
Human liver protein map: Update 1993
Hughes, G. J., Frutiger, S., Paquet, N., Pasquali, C., Sanchez, J., Tissot, J., Bairoch, A., Appel, R. D., & Hochstrasser, D. F. (1993) · Electrophoresis · doi:10.1002/elps.11501401181 · Cited by 73
Righetti, P. G. (1989) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(89)90047-x · Cited by 67
Patton, W. F., Chung‐Welch, N., Lopez, M. F., Cambria, R. P., Utterback, B. L., & Skea, W. M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90350-3 · Cited by 41
Effect of various detergents on protein migration in the second dimension of two-dimensional gels
Lopez, M. F., Patton, W. F., Utterback, B. L., Chung‐Welch, N., Barry, P., Skea, W. M., & Cambria, R. P. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90266-v · Cited by 36
Cited by
Current two‐dimensional electrophoresis technology for proteomics
Görg, A., Weiss, W., & Dunn, M. J. (2004) · PROTEOMICS · doi:10.1002/pmic.200401031 · Cited by 1,822
The current state of two-dimensional electrophoresis with immobilized pH gradients
Görg, A., Obermaier, C., Boguth, G., Harder, A., Scheibe, B., Wildgruber, R., & Weiss, W. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1037::aid-elps1037>3.0.co;2-v · Cited by 1,515
Membrane proteins and proteomics: Un amour impossible?
Santoni, V., Molloy, M., & Rabilloud, T. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1054::aid-elps1054>3.0.co;2-8 · Cited by 852
Self-citationThe dynamic range of protein expression: A challenge for proteomic research
Corthals, G. L., Wasinger, V. C., Hochstrasser, D. F., & Sanchez, J.-C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1104::aid-elps1104>3.0.co;2-c · Cited by 619
Molloy, M. P., Herbert, B. R., Walsh, B. J., Tyler, M. I., Traini, M., Sanchez, J., Hochstrasser, D. F., Williams, K. L., & Gooley, A. A. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150190539 · Cited by 489
Metadata
- Authors
- Rabilloud, T., Valette, C., & Lawrence, J. J.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1994-01
- Volume
- 15
- Issue
- 1
- Pages
- 1552-1558
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2018571987
- Cited by
- 366
- References
- 16
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.