The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Extraction of membrane proteins by differential solubilization for separation using two‐dimensional gel electrophoresis
Abstract
We describe the extraction and enrichment of membrane proteins for separation by two‐dimensional polyacrylamide gel electrophoresis (2‐D PAGE) after differential solubilization of an Escherichia coli cell lysate. In a simple three‐step sequential solubilization protocol applicable for whole cell lysates, membrane proteins are partitioned from other cellular proteins by their insolubility in solutions conventionally used for isoelectric focusing (IEF). As the first step, Tris‐base was used to solubilize many cytosolic proteins. The resultant pellet was then subjected to conventional solubilizing solutions (urea, 3‐[(3‐cholamidopropyl)dimethylammonio]‐1‐propanesulfonate, dithiothreitol, Tris, carrier ampholytes). Following the completion of this step, 89% of the initial E. coli sample mass was solubilized. Finally, the membrane protein rich pellet was partially solubilized using a combination of urea, thiourea, tributyl phosphine and multiple zwitterionic surfactants. Using N‐terminal sequence tagging and peptide mass fingerprinting we have identified 11 membrane proteins from this pellet. Two of these outer membrane proteins (Omp), OmpW and OmpX, have previously been known only as an open reading frame in E. coli, while OmpC, OmpT and OmpTOLC have not previously been identified on a 2‐D gel. The prefractionation of an entire cell lysate into multiple fractions, based on solubility, results in simplified protein patterns following 2‐D PAGE using broad‐range pH 3.5–10 immobilized pH gradients (IPGs). Additional advantages of sample prefractionation are that protein identification and gel matching, for database construction, is a more manageable task, the procedure requires no specialized apparatus, and the sequential extraction is conducted in a single centrifuge tube, minimizing protein loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simple method for displaying the hydropathic character of a protein
Kyte, J., & Doolittle, R. F. (1982) · Journal of Molecular Biology · doi:10.1016/0022-2836(82)90515-0 · Cited by 22,843
Schägger, H., & von Jagow, G. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90587-2 · Cited by 11,444
Escherichia coli and Salmonella :cellular and molecular biology
Neidhardt, F. C. (1996) · ASM Press eBooks · Cited by 8,197
Culture Medium for Enterobacteria
Neidhardt, F. C., Bloch, P. L., & Smith, D. F. (1974) · Journal of Bacteriology · doi:10.1128/jb.119.3.736-747.1974 · Cited by 2,958
Wilkins, M. R., Sanchez, J.-C., Gooley, A. A., Appel, R. D., Humphery-Smith, I., Hochstrasser, D. F., & Williams, K. L. (1996) · Biotechnology and Genetic Engineering Reviews · doi:10.1080/02648725.1996.10647923 · Cited by 1,331
Self-citationGörg, A., Postel, W., & Günther, S. (1988) · ELECTROPHORESIS · doi:10.1002/elps.1150090913 · Cited by 777
Proteome Research: New Frontiers in Functional Genomics
(1997) · Principles and Practice · doi:10.1007/978-3-662-03493-4 · Cited by 480
Rabilloud, T., Adessi, C., Giraudel, A., & Lunardi, J. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150180303 · Cited by 459
Rabilloud, T., Valette, C., & Lawrence, J. J. (1994) · ELECTROPHORESIS · doi:10.1002/elps.11501501223 · Cited by 366
Yerushalmi, H., Lebendiker, M., & Schuldiner, S. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.12.6856 · Cited by 329
Solubilization of proteins for electrophoretic analyses
Rabilloud, T. (1996) · ELECTROPHORESIS · doi:10.1002/elps.1150170503 · Cited by 308
Improved and simplified in‐gel sample application using reswelling of dry immobilized pH gradients
Sanchez, J., Rouge, V., Pisteur, M., Ravier, F., Tonella, L., Moosmayer, M., Wilkins, M. R., & Hochstrasser, D. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150180305 · Cited by 303
Self-citationHerbert, B. R., Molloy, M. P., Gooley, A. A., Walsh, B. J., Bryson, W. G., & Williams, K. L. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150190540 · Cited by 240
Self-citationAdessi, C., Miège, C., Albrieux, C., & Rabilloud, T. (1997) · Electrophoresis · doi:10.1002/elps.1150180124 · Cited by 135
Molloy, M. P., Bolis, S., Herbert, B. R., Ou, K., Tyler, M. I., Dyk, D. D. V., Willcox, M. D. P., Gooley, A. A., Williams, K. L., Morris, C., et al. (1997) · Electrophoresis · doi:10.1002/elps.1150181516 · Cited by 113
Self-citation
Cited by
Current two‐dimensional electrophoresis technology for proteomics
Görg, A., Weiss, W., & Dunn, M. J. (2004) · PROTEOMICS · doi:10.1002/pmic.200401031 · Cited by 1,822
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819
Han, D. K., Eng, J., Zhou, H., & Aebersold, R. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-946 · Cited by 876
Membrane proteins and proteomics: Un amour impossible?
Santoni, V., Molloy, M., & Rabilloud, T. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1054::aid-elps1054>3.0.co;2-8 · Cited by 852
Self-citationCarpentier, S. C., Witters, E., Laukens, K., Deckers, P., Swennen, R., & Panis, B. (2005) · PROTEOMICS · doi:10.1002/pmic.200401222 · Cited by 504
Metadata
- Authors
- Molloy, M. P., Herbert, B. R., Walsh, B. J., Tyler, M. I., Traini, M., Sanchez, J., Hochstrasser, D. F., Williams, K. L., & Gooley, A. A.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1998-05
- Volume
- 19
- Issue
- 5
- Pages
- 837-844
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2007629654
- Cited by
- 489
- References
- 15
- FWCI
- 15.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.