Biomarker discovery by CE‐MS enables sequence analysis via MS/MS with platform‐independent separation

Zürbig, Petra, Renfrow, Matthew B., Schiffer, Eric, Novak, Jan, Walden, Michael, Wittke, Stefan, Just, Ingo, Pelzing, Matthias, Neusüß, Christian, Theodorescu, Dan, Root, Karen E., Ross, Mark M., Mischak, Harald·2006·ELECTROPHORESIS

Abstract

CE‐MS is a successful proteomic platform for the definition of biomarkers in different body fluids. Besides the biomarker defining experimental parameters, CE migration time and molecular weight, especially biomarker's sequence identity is an indispensable cornerstone for deeper insights into the pathophysiological pathways of diseases or for made‐to‐measure therapeutic drug design. Therefore, this report presents a detailed discussion of different peptide sequencing platforms consisting of high performance separation method either coupled on‐line or off‐line to different MS/MS devices, such as MALDI‐TOF‐TOF, ESI‐IT, ESI‐QTOF and Fourier transform ion cyclotron resonance, for sequencing indicative peptides. This comparison demonstrates the unique feature of CE‐MS technology to serve as a reliable basis for the assignment of peptide sequence data obtained using different separation MS/MS methods to the biomarker defining parameters, CE migration time and molecular weight. Discovery of potential biomarkers by CE‐MS enables sequence analysis via MS/MS with platform‐independent sample separation. This is due to the fact that the number of basic and neutral polar amino acids of biomarkers sequences distinctly correlates with their CE‐MS migration time/molecular weight coordinates. This uniqueness facilitates the independent entry of different sequencing platforms for peptide sequencing of CE‐MS‐defined biomarkers from highly complex mixtures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200500827

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 193

Metadata

Authors
Zürbig, P., Renfrow, M. B., Schiffer, E., Novak, J., Walden, M., Wittke, S., Just, I., Pelzing, M., Neusüß, C., Theodorescu, D., Root, K. E., Ross, M. M., & Mischak, H.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2006-05-30
Volume
27
Issue
11
Pages
2111-2125
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W1970252549
Cited by
193
References
1
FWCI
8.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomarker discovery by CE‐MS enables sequence analysis via MS/MS with platform‐independent separation. https://app.cochat.ai/papers/10.1002/elps.200500827
The paper
Zürbig, P., Renfrow, M. B., Schiffer, E., Novak, J., Walden, M., Wittke, S., Just, I., Pelzing, M., Neusüß, C., Theodorescu, D., Root, K. E., Ross, M. M., & Mischak, H. (2006). Biomarker discovery by CE‐MS enables sequence analysis via MS/MS with platform‐independent separation. ELECTROPHORESIS. https://doi.org/10.1002/elps.200500827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.