Recent advances in CE‐MS: Synergy of wet chemistry and instrumentation innovations
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
CE with MS detection is a hyphenated technique which greatly improves the ability of CE to deal with real samples, especially with those coming from biology and medicine, where the target analytes are present as trace amounts in very complex matrices. CE‐MS is now almost a routine technique performed on commercially available instruments. It faces currently a tremendous development of the technique itself as well as of its wide application area. Great interest in CE‐MS is reflected in the scientific literature by many original research articles and also by numerous reviews. The review presented here has a general scope and belongs to a series of regularly published reviews on the topic. It covers the literature from the last 2 years, since January 2008 till June 2010. It brings a critical selection of related literature sorted into groups reflecting the main topics of actual scientific interest: (i) innovations in CE‐ESI‐MS, (ii) use of alternative interfaces, and (iii) ways to enhance sensitivity. Special attention is paid to novel electrolyte systems amenable to CE‐MS including nonvolatile BGEs, to advanced CE separation principles such as MEKC, MEEKC, chiral CE, and to the use of preconcentration techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Ge, L., Yong, J. W. H., Tan, S. N., Hua, L., & Ong, E. S. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200700717 · Cited by 32
Cited by
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Sarg, B., Faserl, K., Kremser, L., Halfinger, B., Sebastiano, R., & Lindner, H. H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.024109 · Cited by 76
“Various interfaces have been constructed to improve CESI-MS coupling (27, 28).”
MethodOn‐line CE/ESI/MS interfacing: Recent developments and applications in proteomics
Krenkova, J., & Foret, F. (2012) · PROTEOMICS · doi:10.1002/pmic.201200140 · Cited by 44
Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43
Metadata
- Authors
- Pantůčková, P., Gebauer, P., Boček, P., & Křivánková, L.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2010-11-30
- Volume
- 32
- Issue
- 1
- Pages
- 43-51
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2141387153
- Cited by
- 54
- References
- 4
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.