CoChat

Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling

Open access

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Abstract

The hyphenation of capillary electrophoresis (CE) with mass spectrometry (MS) is a powerful method to obtain high efficient, sensitive, and selective analyses. The successful coupling with electrospray ionization (ESI) source requires closed electric circuits for both the CE separation and the ESI processes. A wide range of interfaces has been proposed to satisfy this requirement. Among them, the new high sensitivity porous sprayer based on a porous tip achieves the electric connection by inserting the capillary outlet made of a porous material into an ESI needle filled with a conductive liquid and independently grounded. This device is compatible with the minute flow rates exhibited in CE and therefore makes possible the use of a nano‐electrospray behavior. In this work, this interface was evaluated for hyphenating a CE with a single quadrupole MS instrument for low molecular weight analytes. Investigations aimed at highlighting the most influent parameters thanks to a design of experiments, reaching the best performance in terms of sensitivity and stability. MS signal intensities of various pharmaceutical compounds (e.g. amphetamines, β‐blockers) emphasized high sensitivity and efficiency, while repeatability, expressed as relative standard deviation of corrected heights and areas, was suitable for quantitative purposes (<5%).

Overview

Integrity signals

Registry

Crossref · 10.1002/elps.201100461

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 61 references

Research works printed but not linked: 4

  1. Haleem J. I., 2004, J. Chromatogr. A, 1053, 37
  2. Lewis, G. A., 1999, Pharm. Experimental Design
  3. Morgan, E., 1991, Chemometrics: Experimental Design
  4. Kerbarle, P., 1997, Electrospray Ionization Mass Spectrometry: Fundamentals, Instrumentation and Applications, 107

Cited by

See all 48

Metadata

Authors
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J.
Affiliations
University of Geneva (CH)
Corresponding author
Schappler, Julie
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2012-02
Volume
33
Issue
4
Pages
552-562
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2146807700
Cited by
48
References
60
Citations by year
2026: 2 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 5
FWCI
2.54
Type
journal article
Language
en
Open access
Locations
  • Electrophoresis (publishedVersion)
  • PubMed (publishedVersion)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
Keywords
capillary electrophoresis-mass spectrometry, electrospray ionization, low molecular weight analytes, pharmaceutical compounds, amphetamine, beta-blockers, sensitivity, repeatability, experimental design
MeSH terms
Equipment Design, Sensitivity and Specificity, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Nanotechnology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling. https://app.cochat.ai/papers/10.1002/elps.201100461
The paper
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012). Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling. ELECTROPHORESIS. https://doi.org/10.1002/elps.201100461

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.