On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve: CE and CEC
The DOI matches its Crossref record.
Abstract
CE is becoming more and more important in many fields of bioanalytical chemistry. Besides optical detection, hyphenation to ESI-MS detection is increasingly applied for sensitive identification purposes. Unfortunately, many CE techniques and methods established in research and industry are not compatible to ESI-MS since essential components of the background electrolyte interfere in ES ionization. In order to identify unknown peaks in established CE methods, here, a heart-cut 2D-CE separation system is introduced using a fully isolated mechanical valve with an internal loop of only 20 nL. In this system, the sample is separated using potentially any non-ESI compatible method in the first separation dimension. Subsequently, the portion of interest is cut by the internal sample loop of the valve and reintroduced to the second dimension where the interfering compounds are removed, followed by ESI-MS detection. When comparing the separation efficiency of the system with the valve to a system using a continuous capillary only a slight increase in peak width is observed. Ultraviolet/visible detection is integrated in the first dimension for switching time determination, enabling reproducible cutting of peaks of interest. The feasibility of the system is successfully demonstrated by a 2D analysis of a BSA tryptic digest sample using a nonvolatile (phosphate based) background electrolyte in the first dimension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Capillary Electrophoresis: Trends and Recent Advances
Voeten, R. L. C., Ventouri, I. K., Haselberg, R., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00015 · Cited by 315
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Self-citationRecent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Týčová, A., Ledvina, V., & Klepárník, K. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600366 · Cited by 99
Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0542-0 · Cited by 79
Self-citationRecent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Metadata
- Authors
- Kohl, F. J., Montealegre, C., & Neusüß, C.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2016-02-29
- Volume
- 37
- Issue
- 7-8
- Pages
- 954-958
- ISSN
- 0173-0835 (ISSN-L)
- OpenAlex
- W2256958916
- Cited by
- 30
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve: CE and CEC. https://app.cochat.ai/papers/10.1002/elps.201500579
- The paper
- Kohl, F. J., Montealegre, C., & Neusüß, C. (2016). On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve: CE and CEC. ELECTROPHORESIS. https://doi.org/10.1002/elps.201500579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.