Recent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Abstract
This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices coupled with MS for detection and identification of important analytes. It is a continuation of the review article on the same topic by Kleparnik (Electrophoresis 2015, 36, 159–178). A wide selection of 161 relevant articles covers the literature published from June 2014 till May 2016. New improvements in the instrumentation and methodology of MS interfaced with capillary or microfluidic versions of zone electrophoresis, isotachophoresis, and isoelectric focusing are described in detail. The most frequently implemented MS ionization methods include electrospray ionization, matrix‐assisted desorption/ionization and inductively coupled plasma ionization. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single‐cell analysis. The combinations of MS with capillary versions of electrochromatography, and micellar electrokinetic chromatography are not included.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recent advances in CE-MS platforms have attracted considerable interest from the proteomics community as an alternative to LC-MS.
“Recent advances in CE-MS platforms have attracted considerable interest from the proteomics community as an alternative to LC-MS9–11.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [9]
Solvent consumption in CE-MS is very low, making it environmentally advantageous.
“In addition, solvent consumption (aqueous or organic) in CE-MS is very low, making it environmentally advantageous9.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
González‐Domínguez, R., García, A., García‐Barrera, T., Barbas, C., & Gómez‐Ariza, J. L. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201400196 · Cited by 119 · see citing works
Optimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95 · see citing works
Zhong, X., Chen, Z., Snovida, S., Liu, Y., Rogers, J. C., & Li, L. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01835 · Cited by 92 · see citing works
Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92 · see citing works
Zhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac5004486 · Cited by 78 · see citing works
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77 · see citing works
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77 · see citing works
Zhang, Z., Yan, X., Sun, L., Zhu, G., & Dovichi, N. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00789 · Cited by 67 · see citing works
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61 · see citing works
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56 · see citing works
Ludwig, K. R., Sun, L., Zhu, G., Dovichi, N. J., & Hummon, A. B. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02457 · Cited by 56 · see citing works
Zhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55 · see citing works
Jayo, R. G., Thaysen-Andersen, M., Lindenburg, P. W., Haselberg, R., Hankemeier, T., Ramautar, R., & Chen, D. D. Y. (2014) · Analytical Chemistry · doi:10.1021/ac5010212 · Cited by 54 · see citing works
Guo, X., Fillmore, T. L., Gao, Y., & Tang, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04912 · Cited by 54 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123 · see citing works
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61 · see citing works
- Authors
- Týčová, A., Ledvina, V., & Klepárník, K.
- Affiliations
- Czech Academy of Sciences (CZ)
- Institute of Analytical Chemistry Czech Academy of Sciences Brno Czech Republic
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2016-10-26
- Volume
- 38
- Issue
- 1
- Pages
- 115-134
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2542746093
- Cited by
- 99
- References
- 14
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 3 · 2023: 4 · 2022: 7 · 2021: 12 · 2020: 12 · 2019: 14 · 2018: 26 · 2017: 9 · 2016: 1
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Electrophoresis (publishedVersion)
- PubMed (publishedVersion)
- ASEP (submittedVersion, public-domain)
- Funders
- Grantová Agentura České Republiky (14–28254s)
- Akademie Věd České Republiky (68081715)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- CE-MS coupling, capillary electrophoresis, microfluidics, zone electrophoresis, isotachophoresis, isoelectric focusing, electrospray ionization, proteomics, glycomics, metabolomics, biomarkers, forensic analysis, food analysis, single-cell analysis
- MeSH terms
- Cell Line, Chromatography, Food Analysis, Humans, Isoelectric Focusing, Mass Spectrometry, Biomarkers, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Glycomics, Metabolomics, Lab-On-A-Chip Devices, Single-Cell Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review