Comparing isotropic and anisotropic smoothing for voxel‐based DTI analyses: A simulation study
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Voxel‐based analysis (VBA) methods are increasingly being used to compare diffusion tensor image (DTI) properties across different populations of subjects. Although VBA has many advantages, its results are highly dependent on several parameter settings, such as those from the coregistration technique applied to align the data, the smoothing kernel, the statistics, and the post‐hoc analyses. In particular, to increase the signal‐to‐noise ratio and to mitigate the adverse effect of residual image misalignments, DTI data are often smoothed before VBA with an isotropic Gaussian kernel with a full width half maximum up to 16 × 16 × 16 mm 3. However, using isotropic smoothing kernels can significantly partial volume or voxel averaging artifacts, adversely affecting the true diffusion properties of the underlying fiber tissue. In this work, we compared VBA results between the isotropic and an anisotropic Gaussian filtering method using a simulated framework. Our results clearly demonstrate an increased sensitivity and specificity of detecting a predefined simulated pathology when the anisotropic smoothing kernel was used. Hum Brain Mapp, 2010. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“Diffusion tensor magnetic resonance imaging (DT-MRI or DTI) is a unique, noninvasive imaging technique that provides an insight into the complex brain white matter (WM) connectivity [Basser et al., 1994].”
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A three-dimensional statistical analysis for CBF activation studies in human brain
Worsley, K. J., Evans, A. C., Marrett, S., & Neelin, P. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.127 · Cited by 2,036
Detecting activations in PET and fMRI: levels of inference and power
Friston, K. J., Holmes, A., Poline, J.-B., Price, C. J., & Frith, C. D. (1996) · NeuroImage · doi:10.1006/nimg.1996.0074 · Cited by 1,148 · cited 1×
“that the full width at half maximum (FWHM) of the smoothing kernel should at least be two to three times the voxel dimension when analyzing data of a single subject, and even larger for a group analysis, because this FWHM corresponds to the hemodynamic response that should be detected [Friston et al., 1996; Petersson…”
MethodWhy Voxel-based morphometry should be used
Ashburner, J., & Friston, K. J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0961 · Cited by 842
Spatial transformations of diffusion tensor magnetic resonance images
Alexander, D. C., Pierpaoli, C., Basser, P. J., & Gee, J. C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963816 · Cited by 610 · cited 1×
“The preservation of principal direction (PPD) tensor reorientation strategy was thereby incorporated [Alexander et al., 2001; Leemans et al., 2005].”
BackgroundStructural disconnectivity in schizophrenia: a diffusion tensor magnetic resonance imaging study
Burns, J., Job, D., Bastin, M. E., Whalley, H., Macgillivray, T., Johnstone, E. C., & Lawrie, S. M. (2003) · British Journal of Psychiatry · doi:10.1192/bjp.182.5.439 · Cited by 327
Park, H.-J., Westin, C.-F., Kubicki, M., Maier, S. E., Niznikiewicz, M., Baer, A., Frumin, M., Kikinis, R., Jolesz, F. A., McCarley, R. W., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.036 · Cited by 295 · cited 1×
“Although this method to analyze a group of data sets has many advantages compared with other approaches, such as the region of interest based method, recent studies suggest that the VBA results are not always accurate and standardized, because they depend on the parameter settings and implementations of the analysis […”
MethodStatistical limitations in functional neuroimaging II. Signal detection and statistical inference
Petersson, K. M., Nichols, T. E., Poline, J.-B., & Holmes, A. P. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0478 · Cited by 186
Cited by
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citationA hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
“Other shapes can also be used, such as box glyphs which are better for linear anisotropy profiles but, as ellipsoids, they over-look important information and it is difficult to clearly understand 3D shapes when viewed in planes (Vilanova et al., 2006).”
BackgroundRaffelt, D., Tournier, J.-D., Rose, S., Ridgway, G. R., Henderson, R., Crozier, S., Salvado, O., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.045 · Cited by 594
Methodological considerations on tract-based spatial statistics (TBSS)
Bach, M., Laun, F. B., Leemans, A., Tax, C. M. W., Biessels, G. J., Stieltjes, B., & Maier-Hein, K. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.021 · Cited by 445
Self-citationDeprez, S., Amant, F., Smeets, A., Peeters, R., Leemans, A., Van Hecke, W., Verhoeven, J. S., Christiaens, M.-R., Vandenberghe, J., Vandenbulcke, M., et al. (2012) · Journal of Clinical Oncology · doi:10.1200/jco.2011.36.8571 · Cited by 389
Self-citation
Metadata
- Authors
- Van Hecke, W., Leemans, A., De Backer, S., Jeurissen, B., Parizel, P. M., & Sijbers, J.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2009-07-10
- Volume
- 31
- Issue
- 1
- Pages
- 98-114
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2114115018
- Cited by
- 91
- References
- 12
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing isotropic and anisotropic smoothing for voxel‐based DTI analyses: A simulation study. https://app.cochat.ai/papers/10.1002/hbm.20848
- The paper
- Van Hecke, W., Leemans, A., De Backer, S., Jeurissen, B., Parizel, P. M., & Sijbers, J. (2010). Comparing isotropic and anisotropic smoothing for voxel‐based DTI analyses: A simulation study. Human Brain Mapping. https://doi.org/10.1002/hbm.20848
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.