The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Electric field calculations in brain stimulation based on finite elements: An optimized processing pipeline for the generation and usage of accurate individual head models
Open accessAbstract
The need for realistic electric field calculations in human noninvasive brain stimulation is undisputed to more accurately determine the affected brain areas. However, using numerical techniques such as the finite element method (FEM) is methodologically complex, starting with the creation of accurate head models to the integration of the models in the numerical calculations. These problems substantially limit a more widespread application of numerical methods in brain stimulation up to now. We introduce an optimized processing pipeline allowing for the automatic generation of individualized high‐quality head models from magnetic resonance images and their usage in subsequent field calculations based on the FEM. The pipeline starts by extracting the borders between skin, skull, cerebrospinal fluid, gray and white matter. The quality of the resulting surfaces is subsequently improved, allowing for the creation of tetrahedral volume head meshes that can finally be used in the numerical calculations. The pipeline integrates and extends established (and mainly free) software for neuroimaging, computer graphics, and FEM calculations into one easy‐to‐use solution. We demonstrate the successful usage of the pipeline in six subjects, including field calculations for transcranial magnetic stimulation and transcranial direct current stimulation. The quality of the head volume meshes is validated both in terms of capturing the underlying anatomy and of the well‐shapedness of the mesh elements. The latter is crucial to guarantee the numerical robustness of the FEM calculations. The pipeline will be released as open‐source, allowing for the first time to perform realistic field calculations at an acceptable methodological complexity and moderate costs. Hum Brain Mapp, 2013. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Gmsh: A 3‐D finite element mesh generator with built‐in pre‐ and post‐processing facilities
Geuzaine, C., & Remacle, J. (2009) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.2579 · Cited by 7,814
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
NETGEN An advancing front 2D/3D-mesh generator based on abstract rules
Schöberl, J. (1997) · Computing and Visualization in Science · doi:10.1007/s007910050004 · Cited by 1,210
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 453
Optimizing Functional Accuracy of TMS in Cognitive Studies: A Comparison of Methods
Sack, A. T., Cohen Kadosh, R., Schuhmann, T., Moerel, M., Walsh, V., & Goebel, R. (2009) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21126 · Cited by 443
Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation
Thielscher, A., Opitz, A., & Windhoff, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.061 · Cited by 439
Self-citationConductivity tensor mapping of the human brain using diffusion tensor MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J. S., & Belliveau, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171473898 · Cited by 432
How the brain tissue shapes the electric field induced by transcranial magnetic stimulation
Opitz, A., Windhoff, M., Heidemann, R. M., Turner, R., & Thielscher, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.069 · Cited by 360
Self-citationThree-Dimensional Head Model Simulation of Transcranial Magnetic Stimulation
Wagner, T. A., Zahn, M., Grodzinsky, A. J., & Pascual-Leone, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827925 · Cited by 348
Thielscher, A., & Kammer, T. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.019 · Cited by 294
Self-citationModeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
A lightweight approach to repairing digitized polygon meshes
Attene, M. (2010) · The Visual Computer · doi:10.1007/s00371-010-0416-3 · Cited by 253
McConnell, K. A., Nahas, Z., Shastri, A., Lorberbaum, J. P., Kozel, F. A., Bohning, D. E., & George, M. S. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01039-8 · Cited by 251
Distance-adjusted motor threshold for transcranial magnetic stimulation
Stokes, M. G., Chambers, C. D., Gould, I. C., English, T., McNaught, E., McDonald, O., & Mattingley, J. B. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.004 · Cited by 220
Anisotropy in the dielectric properties of skeletal muscle
Epstein, B. R., & Foster, K. R. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446406 · Cited by 219
Güllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 214
Datta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
Wagner, T., Rushmore, J., Eden, U., & Valero-Cabre, A. (2009) · Cortex · doi:10.1016/j.cortex.2008.10.002 · Cited by 188
Brain stimulation using electromagnetic sources: theoretical aspects
Heller, L., & van Hulsteyn, D. B. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81587-4 · Cited by 178
Salvador, R., Silva, S., Basser, P. J., & Miranda, P. C. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.09.022 · Cited by 169
RULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.009 · Cited by 161
Salinas, F. S., Lancaster, J. L., & Fox, P. T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/12/002 · Cited by 118
The cortical motor threshold reflects microstructural properties of cerebral white matter
Klöppel, S., Bäumer, T., Kroeger, J., Koch, M., Büchel, C., Münchau, A. M., & Siebner, H. R. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.019 · Cited by 115
Toschi, N., Welt, T., Guerrisi, M., & Keck, M. (2008) · Physica medica (Testo stampato) · doi:10.1016/j.ejmp.2008.01.005 · Cited by 56
An accurate 3-D model for magnetic stimulation of the brain cortex
Cerri, G., Leo, R. D., Moglie, F., & Schiavoni, A. (1995) · Journal of Medical Engineering & Technology · doi:10.3109/03091909509030264 · Cited by 51
Toschi, N., Welt, T., Guerrisi, M., & Keck, M. (2009) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2008.04.008 · Cited by 45
On tickling brains to investigate minds
Rusconi, E., & Bestmann, S. (2009) · Cortex · doi:10.1016/j.cortex.2009.05.001 · Cited by 8
Cited by
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Thielscher, A., Antunes, A., & Saturnino, G. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318340 · Cited by 942
Self-citationTranscranial focused ultrasound neuromodulation of the human primary motor cortex
Legon, W., Bansal, P., Tyshynsky, R., Ai, L., & Mueller, J. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-28320-1 · Cited by 328
Neymotin, S. A., Daniels, D. S., Caldwell, B., McDougal, R. A., Carnevale, N. T., Jas, M., Moore, C. I., Hines, M. L., Hämäläinen, M., & Jones, S. R. (2020) · eLife · doi:10.7554/elife.51214 · Cited by 109
Wenger, C., Salvador, R., Basser, P. J., & Miranda, P. C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/18/7339 · Cited by 121
Metadata
- Authors
- Windhoff, M., Opitz, A., & Thielscher, A.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2011-11-23
- Volume
- 34
- Issue
- 4
- Pages
- 923-935
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2127919130
- Cited by
- 441
- References
- 33
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.