Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Performance characteristics of vibration‐controlled transient elastography for evaluation of nonalcoholic fatty liver disease

Open access
Vuppalanchi, Raj, Siddiqui, Mohammad S., Van Natta, Mark L., Hallinan, Erin, Brandman, Danielle, Kowdley, Kris, Neuschwander‐Tetri, Brent A., Loomba, Rohit, Dasarathy, Srinivas, Abdelmalek, Manal, Doo, Edward, Tonascia, James A., Kleiner, David E., Sanyal, Arun J., Chalasani, Naga, for the NASH Clinical Research Network·2018·Hepatology

Abstract

Vibration‐controlled transient elastography estimates liver stiffness measurement (LSM) and controlled attenuation parameter (CAP), which are noninvasive assessments of hepatic fibrosis and steatosis, respectively. However, prior vibration‐controlled transient elastography studies reported high failure rates in patients with nonalcoholic fatty liver disease. We examined the performance characteristics of the FibroScan 502 Touch with two probes, medium (M+) and extra large (XL+), in patients with nonalcoholic fatty liver disease in a multicenter setting. A total of 1,696 exams were attempted in 992 patients (body mass index, 33.6 ± 6.5 kg/m 2) with histologically confirmed nonalcoholic fatty liver disease. Simultaneous assessment of LSM and CAP was performed using the FibroScan 502 Touch with an automatic probe selection tool. Testing was conducted twice in patients by either a single operator (87%) or two operators (13%). Failure was defined as the inability to obtain a valid examination. An examination was considered unreliable if LSM interquartile range/median was >30%. Significant disagreement between two readings was defined as >95% limits of agreement between two readings. A total of 1,641 examinations yielded valid results with a failure rate of 3.2% (55/1,696). The proportion of unreliable scans for LSM was 3.9%. The proportion of unreliable scans with operator experience in the top quartile (≥59 procedures) was significantly lower than that in the lower three quarters combined (1.6% versus 4.7%,P= 0.02 by Fisher's exact test). The significant disagreement between first and second readings for LSM and CAP when obtained back to back was 18% and 11%, respectively.Conclusion:Vibration‐controlled transient elastography for estimation of LSM and CAP can be successfully deployed in a multicenter setting with low failure (3.2%) and high reliability (>95%) rates and high reproducibility. (H epatology 2018;67:134‐144).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.29489

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 260

Metadata

Authors
Vuppalanchi, R., Siddiqui, M. S., Van Natta, M. L., Hallinan, E., Brandman, D., Kowdley, K., Neuschwander‐Tetri, B. A., Loomba, R., Dasarathy, S., Abdelmalek, M., Doo, E., Tonascia, J. A., Kleiner, D. E., Sanyal, A. J., Chalasani, N., & for the NASH Clinical Research Network
Venue
Hepatology
Published
2017-11-29
Volume
67
Issue
1
Pages
134-144
ISSN
  • 0270-9139 (ISSN-L)
  • 1527-3350
OpenAlex
W2751367256
Cited by
260
References
40
FWCI
17.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.