CoChat

Oral contrast-enhanced sonography for the diagnosis and grading of postsurgical recurrence of Crohnʼs disease

Open access
Castiglione, Fabiana, Bucci, Luigi, Pesce, Giuseppe, De Palma, Giovanni Domenico, Camera, Luigi, Cipolletta, Fabio, Testa, Anna, Diaferia, Maria, Rispo, Antonio · 2008 · Inflammatory Bowel Diseases
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Postsurgical recurrence (PSR) is very common in patients with Crohn's disease (CD) and previous surgery. Endoscopy is crucial for the diagnosis of PSR, also showing high prognostic value. Bowel sonography (BS) with or without oral contrast enhancement (OCBS) is accurate for CD diagnosis but its role in PSR detection and grading is poorly investigated. The aim was to evaluate the diagnostic accuracy of BS and OCBS for PSR compared to the endoscopical Rutgeerts's grading system. METHODS: We prospectively performed endoscopy, BS, and OCBS in 40 CD patients with previous bowel resection to provide evidence of possible PSR. Endoscopy, BS, and OCBS were executed 1 year after surgery, with PSR diagnosis and grading made in accordance with Rutgeerts. BS and OCBS were considered suggestive for PSR in the presence of bowel wall thickness (BWT) >3 mm. OCBS was performed after ingestion of 750 mL of polyethylene glycol (PEG). Also, a receiver operating characteristic (ROC) curve was constructed in order to define the best cutoff of BWT to discriminate mild from severe PSR (grade 0-2 versus 3-4 of Rutgeerts) for both BS and OCBS. RESULTS: In all, 22 out of the 40 CD showed an endoscopic evidence of PSR (55%). A severe PSR was present in 14 patients (64%). Sensitivity, specificity, and positive and negative predictive values were 77%, 94%, 93%, and 80% for BS, and 82%, 94%, 93%, and 84% for OCBS. On the ROC curve a BWT >5 mm showed sensitivity, specificity, and positive and negative predictive values of 93%, 96%, 88%, and 97% for the diagnosis of severe PSR at BS, while a BWT >4 mm was the best cutoff differentiating the mild from the severe CD recurrence for OCBS, with a sensitivity, specificity, and positive and negative predictive values of 86%, 96%, 97%, and 79%, respectively. CONCLUSIONS: Both BS and OCBS show good sensitivity and high specificity for the diagnosis of PSR in CD, with a BWT >5 mm for BS and BWT >4 mm for OCBS strongly indicative of severe endoscopic PSR. Accordingly, these techniques could replace endoscopy for the diagnosis and grading of PSR in many cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ibd.20469

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Castiglione, F., Bucci, L., Pesce, G., De Palma, G. D., Camera, L., Cipolletta, F., Testa, A., Diaferia, M., & Rispo, A.
Venue
Inflammatory Bowel Diseases
Published
2008-09
Volume
14
Issue
9
Pages
1240-1245
ISSN
1078-0998 (ISSN-L)
OpenAlex
W2161078106
Cited by
111
References
1
FWCI
2.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.