The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Breath gas aldehydes as biomarkers of lung cancer
Abstract
There is experimental evidence that volatile substances in human breath can reflect presence of neoplasma. Volatile aldehydes were determined in exhaled breath of 12 lung cancer patients, 12 smokers and 12 healthy volunteers. Alveolar breath samples were collected under control of expired CO 2. Reactive aldehydes were transformed into stable oximes by means of on‐fiber‐derivatization (SPME‐OFD). Aldehyde concentrations in the ppt and ppb level were determined by means of gas chromatography‐mass spectrometry (GC‐MS). Exhaled concentrations were corrected for inspired values. Exhaled C1–C10 aldehydes could be detected in all healthy volunteers, smokers and lung cancer patients. Concentrations ranged from 7 pmol/l (161 pptV) for butanal to 71 nmol/l (1,582 ppbV) for formaldehyde. Highest inspired concentrations were found for formaldehyde and acetaldehyde (0–55 nmol/l and 0–13 nmol/l, respectively). Acetaldehyde, propanal, butanal, heptanal and decanal concentrations showed no significant differences for cancer patients, smokers and healthy volunteers. Exhaled pentanal, hexanal, octanal and nonanal concentrations were significantly higher in lung cancer patients than in smokers and healthy controls (ppentanal = 0.001; phexanal = 0.006; poctanal = 0.014; pnonanal = 0.025). Sensitivity and specificity of this method were comparable to the diagnostic certitude of conventional serum markers and CT imaging. Lung cancer patients could be identified by means of exhaled pentanal, hexanal, octanal and nonanal concentrations. Exhaled aldehydes reflect aspects of oxidative stress and tumor‐specific tissue composition and metabolism. Noninvasive recognition of lung malignancies may be realized if analytical skills, biochemical knowledge and medical expertise are combined into a joint effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of large amounts of hydrogen peroxide by human tumor cells.
Szatrowski, T. P., & Nathan, C. (1991) · PubMed · Cited by 2,526
Tobacco smoke carcinogens, DNA damage and p53 mutations in smoking-associated cancers
Pfeifer, G. P., Denissenko, M. F., Olivier, M., Tretyakova, N., Hecht, S. S., & Hainaut, P. (2002) · Oncogene · doi:10.1038/sj.onc.1205803 · Cited by 1,112
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationDetection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Poli, D., Carbognani, P., Corradi, M., Goldoni, M., Acampa, O., Balbi, B., Bianchi, L., Rusca, M., & Mutti, A. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-71 · Cited by 415
Molina, R., Filella, X., Augé, J. M., Fuentes, R., Bover, I., Rifa, J., Moreno, V., Canals, E., Viñolas, N., Marquez, A., et al. (2003) · Tumor Biology · doi:10.1159/000074432 · Cited by 275
DENG, C. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.05.015 · Cited by 246
Aldehydes in Exhaled Breath Condensate of Patients with Chronic Obstructive Pulmonary Disease
Corradi, M., Rubinstein, I., Andreoli, R., Manini, P., Caglieri, A., Poli, D., Alinovi, R., & Mutti, A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1253oc · Cited by 242
On the use of Tedlar® bags for breath-gas sampling and analysis
Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046001 · Cited by 236
Detection of lung cancer using weighted digital analysis of breath biomarkers
Phillips, M., Altorki, N., Austin, J. H. M., Cameron, R. B., Cataneo, R. N., Kloss, R., Maxfield, R. A., Munawar, M. I., Pass, H. I., Rashid, A., et al. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.02.021 · Cited by 228
Andreoli, R., Manini, P., Corradi, M., Mutti, A., & Niessen, W. M. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.960 · Cited by 193
Impact of sampling procedures on the results of breath analysis
Miekisch, W., Kischkel, S., Sawacki, A., Liebau, T., Mieth, M., & Schubert, J. K. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026007 · Cited by 174
Self-citationTumor Markers in Detection of Lung Cancer
(2006) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(06)42001-1 · Cited by 163
Phillips, M., Cataneo, R. N., Greenberg, J., Gunawardena, R., Naidu, A., & Rahbari-Oskoui, F. (2000) · Journal of Laboratory and Clinical Medicine · doi:10.1067/mlc.2000.108943 · Cited by 161
Kushch, I., Schwarz, K., Schwentner, L., Baumann, B., Dzien, A., Schmid, A., Unterkofler, K., Gastl, G., Španěl, P., Smith, D. C., et al. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026002 · Cited by 155
Molecular mechanisms of oxidative stress‐induced carcinogenesis: From epidemiology to oxygenomics
Toyokuni, S. (2008) · IUBMB Life · doi:10.1002/iub.61 · Cited by 153
Comparison between exhaled and sputum oxidative stress biomarkers in chronic airway inflammation
Corradi, M., Pignatti, P., Manini, P., Andreoli, R., Goldoni, M., Poppa, M., Moscato, G., Balbi, B., & Mutti, A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00002404 · Cited by 142
Miekisch, W., & Schubert, J. K. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2006.05.006 · Cited by 134
Self-citationEbeler, S. E., Clifford, A. J., & Shibamoto, T. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00369-1 · Cited by 132
Eggink, M., Wijtmans, M., Ekkebus, R., Lingeman, H., de Esch, I. J. P., Kool, J., Niessen, W. M. A., & Irth, H. (2008) · Analytical Chemistry · doi:10.1021/ac801429w · Cited by 122
Orhan, H., Holland, B. J. V., Krab, B., Moeken, J., Vermeulen, N. P. E., Hollander, P., & Meerman, J. H. N. (2004) · Free Radical Research · doi:10.1080/10715760400013763 · Cited by 120
Feng, L., Arimura, H., Suzuki, K., Shiraishi, J., Li, Q., Abé, H., Engelmann, R. M., Sone, S., MacMahon, H., & Doi, K. (2005) · Radiology · doi:10.1148/radiol.2372041555 · Cited by 119
Wang, Q., O’Reilly, J. W., & Pawliszyn, J. B. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.031 · Cited by 115
Li, N., Deng, C., Yin, X., Yao, N., Shen, X., & Zhang, X. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.024 · Cited by 99
Deng, C., Li, N., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.09.007 · Cited by 95
Reinheckel, T., Noack, H., Lorenz, S., Wiswedel, I., & Augustin, W. (1998) · Free Radical Research · doi:10.1080/10715769800300331 · Cited by 86
Headspace Volatile Aldehydes as Indicators of Lipid Oxidation in Foods
Shahidi, F. (2001) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-1247-9_9 · Cited by 85
Wahl, H. G., Hoffmann, A., Häring, H., & Liebich, H. M. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00138-7 · Cited by 81
Cytotoxic Aldehydes as Possible Markers for Childhood Cancer
Yazdanpanah, M., Luo, X., Lau, R., Greenberg, M., Fisher, L., & Lehotay, D. C. (1997) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(97)00070-1 · Cited by 74
Increased oxidative stress in younger as well as in older humans
Phillips, M., Cataneo, R. N., Greenberg, J. H., Gunawardena, R., & Rahbari-Oskoui, F. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00380-7 · Cited by 55
Effect of age on the profile of alkanes in normal human breath
Phillips, M., Greenberg, J. H., & Cataneo, R. N. (2000) · Free Radical Research · doi:10.1080/10715760000300611 · Cited by 54
Svensson, S., Lärstad, M., Broo, K., & Olin, A. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.10.021 · Cited by 54
A novel visually CO2 controlled alveolar breath sampling technique
Birken, T., Schubert, J. K., Miekisch, W., & Nöldge‐Schomburg, G. (2006) · Technology and Health Care · doi:10.3233/thc-2006-14605 · Cited by 53
Self-citationMuley, T., Ébert, W., Stieber, P., Raith, H., Holdenrieder, S., Nagel, D., Fürst, H., Roth, H.-J., Luthe, H., BLIJENBERG, B. G., et al. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.017 · Cited by 29
Cited by
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Qiao, X., Su, B., Liu, C., Song, Q., Luo, D., Mo, G., & Wang, T. (2018) · Advanced Materials · doi:10.1002/adma.201702275 · Cited by 469
Metadata
- Authors
- Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W.
- Venue
- International Journal of Cancer
- Publisher
- Wiley
- Published
- 2010-03-23
- Volume
- 126
- Issue
- 11
- Pages
- 2663-2670
- ISSN
- 0020-7136 (ISSN-L)
- 1097-0215
- OpenAlex
- W2009081566
- Cited by
- 513
- References
- 34
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.