Cited by 1,433

Binding of soluble form of fibroblast surface protein, fibronectin, to collagen

Engvall, Eva, Ruoslahti, Erkki·1977·International Journal of Cancer

Abstract

Fibronectin, a plasma protein immunologically identical with a major surface protein of normal fibroblasts, was found to bind to collagen and gelatin. A solid phase enzyme immunoassay was used for the binding tests. Collagen, gelatin or various control proteins were adsorbed to a plastic surface. Binding of fibronectin was detected using purified fibronectin antibodies conjugated to alkaline phosphatase. Circulating fibronectin and fibronectin obtained from fibroblast cultures both showed specific binding to collagen and gelatin. Preparative affinity chromatography of plasma on gelatin coupled to Sepharose gave electrophoretically and immunologically pure fibronectin in high yields. Malignantly transformed fibroblasts lack surface fibronectin. Our findings suggest the possibility that this results in a lack of anchorage to the surrounding intercellular matrix, which could contribute to the malignant growth behavior.

Integrity signals

Registry

Crossref · 10.1002/ijc.2910200102

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Engvall, E., & Ruoslahti, E.
Venue
International Journal of Cancer
Publisher
Wiley
Published
1977-07-15
Volume
20
Issue
1
Pages
1-5
ISSN
  • 0020-7136
  • 1097-0215
Cited by
1,433
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review