Cited by 4Radiation Dose and ImagingAdvanced Radiotherapy TechniquesRadiology practices and education

Establishment of national diagnostic reference levels as guidelines for computed tomography radiation in Jordan

Al Ewaidat, Haytham, Balawi, Sara, Bataineh, Ziad, Al‐Dwairi, Ahmed, Al‐Khalily, Majd, Azez, Khalaf Abdel, Almakhadmeh, Ali·2023·International Journal of Imaging Systems and Technology

Abstract

Computed tomography (CT) scan contributes to about 10% of the total medical radiographic examinations conducted worldwide. Noticeably, various studies have raised concern regarding the high radiation dose exposure of patients during this technique of imaging. The study assesses the dose of radiation to which patients undergoing different CT examinations in Jordanian hospitals are exposed and measures the national diagnostic reference levels (DRLs). This retrospective observational study of all CT examinations performed in almost 300 plus CT examination centers in Jordan. A random sample of the top 28 hospitals in Jordan was taken for the study, which was conducted between May 2019 and December 2020. We quantified the national DRL by calculating the 75th percentile and the percentage difference of volume CT dose index (CTDIv) and dose length product (DLP) for both pediatric and adult populations and different CT examinations, including brain, sinus, chest, abdomen & pelvis, knee, neck, lumbar‐spine, cervical‐spine, and shoulder. A total of 242 pediatric patients and 304 adult patients underwent various CT examinations during the study period. The national DRLs (the 75th percentiles of CTDIv and DLP) for the pediatric population were highest for the brain (81 mGy and 1425 mGy.cm, respectively) and lowest for the shoulder (7 mGy and 181 mGy.cm, respectively). Similarly, the 75th percentiles of CTDIv for the adults were highest for the brain examination (68 mGy) and lowest for the shoulder (8 mGy). The national DRLs for CT scans conducted in Jordan hospitals were found to be higher than those quantified in other countries, with larger CTDIv and DLP variations.

Integrity signals

Registry

Crossref · 10.1002/ima.22855

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In Jordan, an increasing emphasis on radiation protection and quality assurance in medical imaging has initiated endeavors to create and revise national CT diagnostic reference levels (DRLs).

    “In Jordan, an increasing emphasis on radiation protection and quality assurance in medical imaging has initiated endeavors to create and revise national CT diagnostic reference levels (DRLs).6–8”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Al Ewaidat, H., Balawi, S., Bataineh, Z., Al‐Dwairi, A., Al‐Khalily, M., Azez, K. A., & Almakhadmeh, A.
Affiliations
  • Department of Allied Medical Sciences‐Radiologic Technology, Faculty of Applied Medical Sciences Jordan University of Science and Technology Irbid Jordan
  • Jordan University of Science and Technology (JO)
  • The University of Queensland (AU)
Venue
International Journal of Imaging Systems and Technology
Publisher
Wiley
Published
2023-01-29
Volume
33
Issue
4
Pages
1223-1234
ISSN
  • 0899-9457 (ISSN-L)
  • 1098-1098
OpenAlex
W4318465072
Cited by
4
References
16
Citations by year
2026: 2 · 2025: 1 · 2023: 1
FWCI
0.66
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Imaging Systems and Technology (publishedVersion)
Funders
Jordan University of Science and Technology (20200649)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
computed tomography, diagnostic reference levels, patient radiation dose, volume CT dose index, dose-length product, pediatric CT, Jordan, radiation protection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review