Non‐invasive multiphoton imaging of extracellular matrix structures
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Multiphoton microscopy has become a powerful method for the artifact‐free, nondestructive evaluation of deep‐tissue cells and extracellular matrix (ECM) structures in their native environment. By interacting with highly non‐centrosymmetric molecular assemblies such as fibrillar collagen, the non‐linear process called second harmonic generation (SHG) has also proven to be an important diagnostic tool for the visualization of ECM compartments in situ with submicron resolution without the need for tissue processing. This review reports on applications of multiphoton‐induced autofluorescence and SHG microscopy to identify collagen and elastic fiber orientation in native, tissue‐engineered and processed, as well as healthy and diseased, tissues and organs. SHG signal profiling was used to quantify ECM damage in various cardiovascular and exocrine tissues, as well as cartilage. These novel imaging modalities open the general possibility of high‐resolution in situ and more important in vivo imaging of ECM structures, cells and intracellular organelles in living intact tissues. (© 2008 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Hinderer, S., Layland, S. L., & Schenke-Layland, K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.019 · Cited by 469
“structure post-decellularization or cryopreservation [55].”
Self-citationImaging challenges in biomaterials and tissue engineering
Appel, A. A., Anastasio, M. A., Larson, J. C., & Brey, E. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.033 · Cited by 273
Towards organ printing: engineering an intra-organ branched vascular tree
Visconti, R. P., Kasyanov, V., Gentile, C., Zhang, J., Markwald, R. R., & Mironov, V. (2010) · Expert Opinion on Biological Therapy · doi:10.1517/14712590903563352 · Cited by 224
“A combination of non-invasive molecular imaging techniques such as multiphoton microscopy for non-destructive visualization of elastin and collagen deposition [92], utilization of cells transfected with reporter genes such as collagen type I and alpha smooth muscle actin labeled with fluorescent proteins [93,94], nano…”
MethodHinderer, S., Brauchle, E., & Schenke‐Layland, K. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400762 · Cited by 68
Self-citation
Metadata
- Authors
- Schenke‐Layland, K.
- Venue
- Journal of Biophotonics
- Publisher
- Wiley
- Published
- 2008-12
- Volume
- 1
- Issue
- 6
- Pages
- 451-462
- ISSN
- 1864-063X (ISSN-L)
- 1864-0648
- OpenAlex
- W2062044315
- Cited by
- 108
- References
- 2
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.