Adsorption of proteins from infant and adult plasma to biomaterial surfaces
The DOI matches its Crossref record.
Abstract
The hemostatic mechanism of the newborn is immature. In general, the clotting times in screening tests are prolonged, the coagulation factors are low, and the coagulation inhibitors (with the exception of alpha‐2‐macroglobulin) are low. Recognizing that many of the proteins present in infant plasma are at low levels, it is of interest to determine if, following exposure to artificial surfaces, the profile of adsorbed proteins is different for infant versus adult plasma. The question of whether differences in protein profiles could lead to differences in thromboembolic episodes associated with the use of central venous catheters (or other blood‐contacting devices) in infant versus adult subjects also is relevant. To address these issues, the adsorption of proteins from pooled infant plasma and pooled normal adult plasma to three different polymer surfaces (polyvinyl chloride, PVC; polymethyl methacrylate, PMMA; and polyethylene oxide‐modified polyurethane, PEO‐PU) was studied using SDS‐PAGE and immunoblotting techniques. The total amount of protein adsorbed to each surface also was determined. It was found that the PMMA and PVC surfaces adsorbed considerably more protein than the PEO‐PU surface. Furthermore, the amount of protein adsorbed to the PMMA and PVC surfaces from infant plasma was significantly less than that adsorbed from adult plasma. No such difference was seen for the protein‐repellent PEO‐PU surface. The immunoblot responses of proteins bound to the PMMA and PVC surfaces from infant plasma were, in general, weaker than those bound from adult plasma. It is likely that these differences were due to decreased protein levels in infant plasma. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 622–632, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Self-citationLin, K., Xia, L., Gan, J., Zhang, Z., Chen, H., Jiang, X., & Chang, J. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am402089w · Cited by 229
Metadata
- Authors
- Cornelius, R. M., Archambault, J. G., Berry, L., Chan, A. K. C., & Brash, J. L.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-03-25
- Volume
- 60
- Issue
- 4
- Pages
- 622-632
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2007967324
- Cited by
- 54
- References
- 0
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adsorption of proteins from infant and adult plasma to biomaterial surfaces. https://app.cochat.ai/papers/10.1002/jbm.10117
- The paper
- Cornelius, R. M., Archambault, J. G., Berry, L., Chan, A. K. C., & Brash, J. L. (2002). Adsorption of proteins from infant and adult plasma to biomaterial surfaces. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.