The DOI matches its Crossref record.
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Abstract
The design and application of sensors for monitoring biomolecules in clinical samples is a common goal of the sensing research community. Surface plasmon resonance (SPR) and other plasmonic techniques such as localized surface plasmon resonance (LSPR) and imaging SPR are reaching a maturity level sufficient for their application in monitoring biomolecules in clinical samples. In recent years, the first examples for monitoring antibodies, proteins, enzymes, drugs, small molecules, peptides, and nucleic acids in biofluids collected from patients afflicted with a series of medical conditions (Alzheimer's, hepatitis, diabetes, leukemia, and cancers such as prostate and breast cancers, among others) demonstrate the progress of SPR sensing in clinical chemistry. This Perspective reviews the current status of the field, showcasing a series of early successes in the application of SPR for clinical analysis and detailing a series of considerations regarding sensing schemes, exposing issues with analysis in biofluids, and comparing SPR with ELISA, while providing an outlook of the challenges currently associated with plasmonic materials, instrumentation, microfluidics, bioreceptor selection, selection of a clinical market, and validation of a clinical assay for applying SPR sensors to clinical samples. Research opportunities are proposed to further advance the field and transition SPR biosensors from research proof-of-concept stage to actual clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Carbon and Graphene Quantum Dots for Sensing
Li, M., Chen, T., Gooding, J. J., & Liu, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00514 · Cited by 991
Multiplexed Point-of-Care Testing – xPOCT
Dincer, C., Bruch, R., Kling, A., Dittrich, P. S., & Urban, G. A. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.013 · Cited by 503
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Metadata
- Authors
- Masson, J.-F.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-01-06
- Volume
- 2
- Issue
- 1
- Pages
- 16-30
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2567163077
- Cited by
- 663
- References
- 0
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics. https://app.cochat.ai/papers/10.1021/acssensors.6b00763
- The paper
- Masson, J.-F. (2017). Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics. ACS Sensors. https://doi.org/10.1021/acssensors.6b00763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.