Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials

Valdes, T.I., Kreutzer, D., Moussy, F.·2002·Journal of Biomedical Materials Research

Abstract

Current in vivo models for testing biomaterials are time and labor intensive as well as expensive. This article describes a new approach for testing biomaterials in vivo using the chorioallantoic membrane (CAM) of the developing chicken embryo, as an alternative to the traditional mammalian models. Fertilized chicken eggs were incubated for 4 days, at which time a small window was cut in the shell of the egg. After 1 week of incubation, the CAM received several test materials, including the endotoxin LPS, a cotton thread and a Silastic tubing. One day and 1 week later, the tissue response to the test materials was assessed using gross, histological, and scanning electron microscope evaluations. The inflammatory response of the chorioallantoic membrane to biomaterials was fully characterized and found to be similar to that of the mammalian response and was also seen to vary according to test materials. We also found that the structure and geometry of the test materials greatly influenced the incorporation of the samples in the CAM. The similarity of the tissue response of the CAM with the mammalian models, plus the low cost, simplicity, and possibility to continuously visualize the test site through the shell window make this animal model particularly attractive for the rapid in vivo screening of biomaterials. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 273–282, 2002

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.10152

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Valdes, T. I., Kreutzer, D., & Moussy, F.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
2002-08-02
Volume
62
Issue
2
Pages
273-282
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2115452170
Cited by
191
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials. https://app.cochat.ai/papers/10.1002/jbm.10152
The paper
Valdes, T. I., Kreutzer, D., & Moussy, F. (2002). The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10152

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.