The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Abstract
The optimal pore size for bone ingrowth is claimed to be 100–400 μm. With the use of a highly standardized experimental model, the present study reevaluated whether a pore size of 100 μm is the threshold value for bone ingrowth into porous structures under non‐load‐bearing conditions. Titanium triangle‐shaped plates 250 or 500 μm thick were perforated with the use of a laser in order to create standard‐sized holes (∅︁ 50, 75, 100, and 125 μm) in multiple rows. The amount of bone ingrowth through the implant holes was studied in the cancellous bone of the distal rabbit femur. Twelve weeks after implantation, detailed analysis of bone ingrowth was performed with computerized image analysis of backscattered electron imaging techniques of scanning electron microscopy. The results showed that the amount of ingrown new bone was independent of the pore size and implant thickness. The median value for bone ingrowth varied between 64 and 78%. A striking feature was the formation of secondary osteonal structures even in the smallest holes. Based on these results, there is no threshold value for new bone ingrowth in pore sizes ranging from 50 to 125 μm under non‐load‐bearing conditions. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 679–683, 2001
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential of ceramic materials as permanently implantable skeletal prostheses
Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., & Stelling, F. H. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040309 · Cited by 1,019
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Simon, S. R. (1994) · American Academy of Orthopaedic Surgeons eBooks · Cited by 403
Growth of bone marrow cells on porous ceramics in vitro
Uchida, A., Nade, S., McCartney, E., & Ching, W. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210106 · Cited by 233
The rate of bone ingrowth into porous metal
Camron, H. U., Pilliar, R. M., & Macnab, I. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100210 · Cited by 208
CORALLINE BONE GRAFT SUBSTITUTES
Shors, E. C. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70113-9 · Cited by 160
Porous‐surfaced metallic implants for orthopedic applications
Pilliar, R. M. (1987) · Journal of Biomedical Materials Research · doi:10.1002/j.1097-4636.1987.tb00003.x · Cited by 146
Schliephake, H., Neukam, F. W., & Klosa, D. (1991) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0901-5027(05)80698-8 · Cited by 126
Progression of human bone ingrowth into porous-coated implants: Rate of bone ingrowth in humans
Hofmann, A. A., Bloebaum, R. D., & Bachus, K. N. (1997) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679709004000 · Cited by 94
Mineral apposition rates of human cancellous bone at the interface of porous coated implants
Bloebaum, R. D., Bachus, K. N., Momberger, N. G., & Hofmann, A. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280503 · Cited by 80
Measuring the volume fraction of bone ingrowth: A comparison of three techniques
Sumner, D. R., Bryan, J. M., Urban, R. M., & Kuszak, J. R. (1990) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100080316 · Cited by 67
Cited by
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Freeze casting of hydroxyapatite scaffolds for bone tissue engineering
Deville, S., Saiz, E., & Tomsia, A. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.028 · Cited by 873
Cell proliferation and migration in silk fibroin 3D scaffolds
Mandal, B. B., & Kundu, S. C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.006 · Cited by 583
Hannink, G., & Arts, J. J. C. (2011) · Injury · doi:10.1016/j.injury.2011.06.008 · Cited by 444
Metadata
- Authors
- Itälä, A. I., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 58
- Issue
- 6
- Pages
- 679-683
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2058203839
- Cited by
- 379
- References
- 11
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.