The DOI matches its Crossref record.
In vitro generation of differentiated cardiac myofibers on micropatterned laminin surfaces
Abstract
Cardiac muscle fibers consist of highly aligned cardiomyocytes containing myofibrils oriented parallel to the fiber axis, and successive cardiomyocytes are interconnected at their ends through specialized junctional complexes (intercalated disks). Cell culture studies of cardiac myofibrils and intercalated disks are complicated by the fact that cardiomyocytes become extremely flattened and exhibit disorganized myofibrils and diffuse intercellular junctions with neighboring cells. In this study we sought to direct the organization of cultured cardiomyocytes to more closely resemble that found in vivo. Lanes of laminin 5–50 μm wide were microcontact‐printed onto nonadhesive (BSA‐coated) surfaces. Adherent cardiomyocytes responded to the spatial constraints by forming elongated, rod‐shaped cells whose myofibrils aligned parallel to the laminin lanes. Patterned cardiomyocytes displayed a striking, bipolar localization of the junction molecules N‐cadherin and connexin43 that ultrastructurally resembled intercalated disks. When laminin lanes were widely spaced, each lane of cardiomyocytes beat independently, but with narrow‐spacing cells bridged between lanes, yielding aligned fields of synchronously beating cardiomyocytes. Similar cardiomyocyte patterns were achieved on the biodegradable polymer PLGA, suggesting that patterned cardiomyocytes could be used in myocardial tissue engineering. Such highly patterned cultures could be used in cell biology and physiology studies, which require accurate reproduction of native myocardial architecture. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 472–479, 2002; DOI 10.1008/jbm.1292
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineering Adolescence: Maturation of Human Pluripotent Stem Cell–Derived Cardiomyocytes
Yang, X., Pabon, L., & Murry, C. E. (2014) · Circulation Research · doi:10.1161/circresaha.114.300558 · Cited by 939
Self-citationCardiomyocyte maturation: advances in knowledge and implications for regenerative medicine
Karbassi, E., Fenix, A., Marchiano, S., Muraoka, N., Nakamura, K., Yang, X., & Murry, C. E. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0331-x · Cited by 755
Self-citationStructural and Functional Maturation of Cardiomyocytes Derived from Human Pluripotent Stem Cells
Lundy, S. D., Zhu, W.-Z., Regnier, M., & Laflamme, M. A. (2013) · Stem Cells and Development · doi:10.1089/scd.2012.0490 · Cited by 738
Proangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662
Self-citationNanoscale cues regulate the structure and function of macroscopic cardiac tissue constructs
Kim, D.-H., Lipke, E. A., Kim, P., Cheong, R., Thompson, S., Delannoy, M., Suh, K.-Y., Tung, L., & Levchenko, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906504107 · Cited by 611
Nanotopography-guided tissue engineering and regenerative medicine
Kim, H. N., Jiao, A., Hwang, N. S., Kim, M. S., Kang, D. H., Kim, D.-H., & Suh, K.-Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.014 · Cited by 404
Three-Dimensional BioAssembly Tool for Generating Viable Tissue-Engineered Constructs
Smith, C. M., Stone, A. L., Parkhill, R. L., Stewart, R. L., Simpkins, M. W., Kachurin, A. M., Warren, W. L., & Williams, S. K. (2004) · Tissue Engineering · doi:10.1089/1076327042500274 · Cited by 373
Tallawi, M., Rosellini, E., Barbani, N., Cascone, M. G., Rai, R., Saint-Pierre, G., & Boccaccini, A. R. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2015.0254 · Cited by 366
Cells, scaffolds, and molecules for myocardial tissue engineering
Leor, J., Amsalem, Y., & Cohen, S. (2005) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2004.10.003 · Cited by 344
Tissue Engineering Approaches in the Design of Healthy and Pathological In Vitro Tissue Models
Caddeo, S., Boffito, M., & Sartori, S. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00040 · Cited by 285
Bursac, N., Parker, K. K., Iravanian, S., & Tung, L. (2002) · Circulation Research · doi:10.1161/01.res.0000047530.88338.eb · Cited by 268
Immaturity of Human Stem-Cell-Derived Cardiomyocytes in Culture: Fatal Flaw or Soluble Problem?
Veerman, C. C., Kosmidis, G., Mummery, C. L., Casini, S., Verkerk, A. O., & Bellin, M. (2015) · Stem Cells and Development · doi:10.1089/scd.2014.0533 · Cited by 265
Zhu, W.-Z., Xie, Y., Moyes, K. W., Gold, J. D., Askari, B., & Laflamme, M. A. (2010) · Circulation Research · doi:10.1161/circresaha.110.223917 · Cited by 228
In vitro cardiac tissue models: Current status and future prospects
Mathur, A., Ma, Z., Loskill, P., Jeeawoody, S., & Healy, K. E. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.011 · Cited by 187
A photolithographic method to create cellular micropatterns
Karp, J. M., Yeo, Y., Geng, W., Cannizarro, C., Yan, K., Kohane, D. S., Vunjak-Novakovic, G., Langer, R. S., & Radisic, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.028 · Cited by 134
Biomechanics of Cardiac Electromechanical Coupling and Mechanoelectric Feedback
Pfeiffer, E. R., Tangney, J. R., Omens, J. H., & McCulloch, A. D. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026221 · Cited by 131
Guo, Y., Jardin, B. D., Zhou, P., Sethi, I., Akerberg, B. N., Toepfer, C. N., Ai, Y., Li, Y., Ma, Q., Guatimosim, S., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06347-2 · Cited by 96
Fang, Y., Sun, W., Zhang, T., & Xiong, Z. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2021.121298 · Cited by 40
Metadata
- Authors
- McDevitt, T. C., Angello, J. C., Whitney, M. L., Reinecke, H., Hauschka, S. D., Murry, C. E., & Stayton, P. S.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-02-13
- Volume
- 60
- Issue
- 3
- Pages
- 472-479
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2155828174
- Cited by
- 197
- References
- 0
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.