The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Three-Dimensional BioAssembly Tool for Generating Viable Tissue-Engineered Constructs
Abstract
The primary emphasis of tissue engineering is the design and fabrication of constructs for the replacement of nonfunctional tissue. Because tissue represents a highly organized interplay of cells and extracellular matrix, the fabrication of replacement tissue should mimic this spatial organization. This report details studies evaluating the use of a three-dimensional, direct-write cell deposition system to construct spatially organized viable structures. A direct-write bioassembly system was designed and fabricated to permit layer-by-layer placement of cells and extracellular matrix on a variety of material substrates. Human fibroblasts suspended in polyoxyethylene/polyoxypropylene were coextruded through a positive displacement pen delivery onto a polystyrene slide. After deposition, approximately 60% of the fibroblasts remained viable. Bovine aortic endothelial cells (BAECs) suspended in soluble collagen type I were coextruded via microdispense pen delivery onto the hydrophilic side of flat sheets of polyethylene terephthalate. After deposition with a 25-gauge tip, approximately 86% of the BAECs were viable. When maintained in culture for up to 35 days, the constructs remained viable and maintained their original spatial organization. These results indicate the potential for utilizing a direct-write, three-dimensional bioassembly tool to create viable, patterned tissue-engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701
Cited by
3D bioprinting of tissues and organs
Murphy, S. V., & Atala, A. (2014) · Nature Biotechnology · doi:10.1038/nbt.2958 · Cited by 7,034
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
The bioink: A comprehensive review on bioprintable materials
Hospodiuk, M., Dey, M., Sosnoski, D., & Ozbolat, I. T. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.12.006 · Cited by 1,118
Tissue engineering by self-assembly and bio-printing of living cells
Jakab, K., Norotte, C., Marga, F., Murphy, K., Vunjak-Novakovic, G., & Forgacs, G. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/022001 · Cited by 593
Advances in the formation, use and understanding of multi-cellular spheroids
Achilli, T.-M., Meyer, J., & Morgan, J. R. (2012) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2012.707181 · Cited by 572
Metadata
- Authors
- Smith, C. M., Stone, A. L., Parkhill, R. L., Stewart, R. L., Simpkins, M. W., Kachurin, A. M., Warren, W. L., & Williams, S. K.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2004-09-01
- Volume
- 10
- Issue
- 9
- Pages
- 1566-1576
- ISSN
- 1076-3279 (ISSN-L)
- OpenAlex
- W2045047041
- Cited by
- 373
- References
- 1
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional BioAssembly Tool for Generating Viable Tissue-Engineered Constructs. https://app.cochat.ai/papers/10.1089/1076327042500274
- The paper
- Smith, C. M., Stone, A. L., Parkhill, R. L., Stewart, R. L., Simpkins, M. W., Kachurin, A. M., Warren, W. L., & Williams, S. K. (2004). Three-Dimensional BioAssembly Tool for Generating Viable Tissue-Engineered Constructs. Tissue Engineering. https://doi.org/10.1089/1076327042500274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.