Transcutaneous implants: Reactions of the skin‐implant interface
The DOI matches its Crossref record.
Abstract
One method of providing an artificial limb for an amputee might be to attach the external prosthesis directly to the skeleton but a major problem is the behavior of the tissues at the point where the prosthesis penetrates the skin surface. Preliminary experiments have been carried out using small flexible implants in porcine skin to study the principles involved. It is confirmed that the epidermis grows down into the dermis around the nonporous materials and the implant‐skin junction is unstable and readily becomes infected. It was found that polytetrafluorethylene with pores of 10 μm diameter and hydron sponge with pores of 40 μm diameter became invaded by fibrous tissue and this appeared to prevent the migration of epidermis alongside the implants and a stable ring of epidermal tissue was formed near the skin surface. A review of other situations where epidermal migration is taking place suggests that epidermis is able to migrate through damaged collagenous tissue, possibly with the help of leucocytic enzymes, but that epidermal cell movement is halted when the epidermal sheet is confronted by heathly collagen bundles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermoresponsive chitosan–agarose hydrogel for skin regeneration
Miguel, S. P., Ribeiro, M. P., Brancal, H., Coutinho, P., & Correia, I. J. (2014) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2014.04.093 · Cited by 290
Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses
Pendegrass, C. J., Goodship, A. E., & Blunn, G. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.041 · Cited by 166
Fukano, Y., Usui, M. L., Underwood, R. A., Isenhath, S., Marshall, A. J., Hauch, K. D., Ratner, B. D., Olerud, J. E., & Fleckman, P. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32798 · Cited by 83
A mouse model to evaluate the interface between skin and a percutaneous device
Isenhath, S. N., Fukano, Y., Usui, M. L., Underwood, R. A., Irvin, C. A., Marshall, A. J., Hauch, K. D., Ratner, B. D., Fleckman, P., & Olerud, J. E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31391 · Cited by 59
Underwood, R. A., Usui, M. L., Zhao, G., Hauch, K. D., Takeno, M. M., Ratner, B. D., Marshall, A. J., Shi, X., Olerud, J. E., & Fleckman, P. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33125 · Cited by 52
Metadata
- Authors
- Winter, G. D.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1974-01
- Volume
- 8
- Issue
- 3
- Pages
- 99-113
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2030196499
- Cited by
- 131
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcutaneous implants: Reactions of the skin‐implant interface. https://app.cochat.ai/papers/10.1002/jbm.820080311
- The paper
- Winter, G. D. (1974). Transcutaneous implants: Reactions of the skin‐implant interface. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820080311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.