The DOI matches its Crossref record.
The rate of bone ingrowth into porous metal
Abstract
Experiments have been devised to study the rate of ingrowth of bone into porous metal with pore sizes up to 100 μ and to study the significance of a gap between the porous metal surface and bone. When the porous coat was in direct apposition with bone, the implant was firmly locked in place after a three week period and the plateau value of implanttissue shear strength was reached at four weeks. A gap of 1.5 mm between the bone and the implant was bridged by new bone wihtin four weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
Bobyn, J. D., Stackpool, G. J., Hacking, S. A., Tanzer, M., & Krygier, J. J. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b5.0810907 · Cited by 1,037
Additive Manufacturing of Titanium Alloys by Electron Beam Melting: A Review
Zhang, L., Liu, Y., Li, S., & Hao, Y. (2018) · Advanced Engineering Materials · doi:10.1002/adem.201700842 · Cited by 486
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Itälä, A. I., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1069 · Cited by 379
Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique
Ryan, G. E., Pandit, A. S., & Apatsidis, D. P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.032 · Cited by 340
Direct laser processing of a tantalum coating on titanium for bone replacement structures
Balla, V. K., Banerjee, S., Bose, S., & Bandyopadhyay, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.021 · Cited by 333
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
Implant surface characteristics and their effect on osseointegration
Barfeie, A., Wilson, J., & Rees, J. (2015) · British Dental Journal · doi:10.1038/sj.bdj.2015.171 · Cited by 292
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Surface morphology optimization for osseointegration of coated implants
Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.077 · Cited by 105
Metadata
- Authors
- Camron, H. U., Pilliar, R. M., & Macnab, I.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1976-03
- Volume
- 10
- Issue
- 2
- Pages
- 295-302
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2101798843
- Cited by
- 208
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.