The DOI matches its Crossref record.
Design of an artificial skin. II. Control of chemical composition
Abstract
Detailed methodology is described for the reproducible preparation of collagen‐glycosaminoglycan (GAG) membranes with known chemical composition. These membranes have been used to cover satisfactorily large experimental full‐thickness skin wounds in guinea pigs over the past few years. Such membranes have effectively protected these wounds from infection and fluid loss for over 25 days without rejection and without requiring change or other invasive manipulation. When appropriately designed for the purpose, the membranes have also strongly retarded wound contraction and have become replaced by newly synthesized, stable connective tissue. In our work, purified, fully native collagen from two mammalian sources is precipitated from acid dispersion by addition of chondroitin 6‐sulfate. The relative amount of GAG in the coprecipitate varies with the amount of GAG added and with the pH. Since coprecipitated GAG is generally eluted from collagen fibers by physiological fluids, control of the chemical composition of membranes is arrived at by crosslinking the collagen‐GAG ionic complex with glutaraldehyde, or, alternately, by use of high‐temperature vacuum dehydration. Appropriate use of the crosslinking treatment allows separate study of changes in membrane composition due to elution of GAG by extracellular fluid in animal studies from changes in composition due to enzymatic degradation of the grafted or implanted membrane in these studies. Exhaustive in vitro elution studies extending up to 20 days showed that these crosslinking treatments insolubilize in an apparently permanent manner a fraction of the ionically complexed GAG, although it could not be directly confirmed that glutaraldehyde treatment covalently crosslinks GAG to collagen. By contrast, the available evidence suggests strongly that high‐temperature vacuum dehydration leads to formation of chemical bonds between collagen and GAG. Procedures are described for control of insolubilized and “free” GAG in these membranes as well as for control of the molecular weight between crosslinks (Mc). The insolubilized GAG can be controlled in the range 0.5–10 wt. % while “free” GAG can be independently controlled up to at least 25 wt. %; Mc can be controlled in the range 2500–40,000. Studies by infrared spectroscopy have shown that treatment of collagen‐GAG membranes by glutaraldehyde or under high‐temperature vacuum does not alter the configuration of the collagen triple helix in the membranes. Neither do these treatments modify the native banding pattern of collagen as viewed by electron microscopy. Collagen‐GAG membranes appear to be useful as chemically well‐characterized, solid macromolecular probes of biomaterial‐tissue interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomaterials & scaffolds for tissue engineering
O'Brien, F. J. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70058-x · Cited by 3,437
Biomaterials based on chitin and chitosan in wound dressing applications
Jayakumar, R., Prabaharan, M., Sudheesh Kumar, P. T., Nair, S. V., & Tamura, H. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.01.005 · Cited by 1,924
Design of an artificial skin. Part III. Control of pore structure
Dagalakis, N., Flink, J., Stasikelis, P., Burke, J. F., & Yannas, I. V. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140417 · Cited by 358
Self-citationLyons, F. G., Al-Munajjed, A. A., Kieran, S. M., Toner, M. E., Murphy, C. M., Duffy, G. P., & O’Brien, F. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.056 · Cited by 222
Collagen in Dermal Wound Repair
McPherson, J. M., & Piez, K. A. (1988) · The Molecular and Cellular Biology of Wound Repair · doi:10.1007/978-1-4615-1795-5_20 · Cited by 39
Metadata
- Authors
- Yannas, I. V., Burke, J. F., Gordon, P. L., Huang, C., & Rubenstein, R. H.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1980-03
- Volume
- 14
- Issue
- 2
- Pages
- 107-132
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2125240138
- Cited by
- 590
- References
- 0
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of an artificial skin. II. Control of chemical composition. https://app.cochat.ai/papers/10.1002/jbm.820140203
- The paper
- Yannas, I. V., Burke, J. F., Gordon, P. L., Huang, C., & Rubenstein, R. H. (1980). Design of an artificial skin. II. Control of chemical composition. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820140203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.