Applications and failure modes of percutaneous devices: A review
The DOI matches its Crossref record.
Abstract
Percutaneous devices (PD) are designed to serve a variety of clinical and biomedical research purposes. Characteristically they are objects that permanently penetrate through a defect in the skin. The histological aspects of the implant skin interfacial reactions are reviewed in this article. A short description is presented of common applications of PDs. The five presently identified interfacial failure modes are described histologically with the aid of schematic drawings. These failure modes are marsupialization, permigration, avulsion, infection, alone or in combination. Single or multiple etiological factors may be responsible for these failure modes. These factors can be surgically created skin defects around the penetrating foreign implant, epidermal healing characteristics that prevent the formation of a suitable seal at the implant‐skin interface and mechanical forces that may disrupt dermal attempts to seal the interface. Eventually the interface becomes infected necessitating removal of the device. Terminology recommended for use in percutaneous device research is indexed and defined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses
Pendegrass, C. J., Goodship, A. E., & Blunn, G. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.041 · Cited by 166
Viscoelastic response of human skin to low magnitude physiologically relevant shear
Holt, B., Tripathi, A., & Morgan, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.008 · Cited by 161
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Fukano, Y., Usui, M. L., Underwood, R. A., Isenhath, S., Marshall, A. J., Hauch, K. D., Ratner, B. D., Olerud, J. E., & Fleckman, P. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32798 · Cited by 83
Metadata
- Authors
- von Recum, A. F.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1984-04
- Volume
- 18
- Issue
- 4
- Pages
- 323-336
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2061568483
- Cited by
- 202
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Applications and failure modes of percutaneous devices: A review. https://app.cochat.ai/papers/10.1002/jbm.820180403
- The paper
- von Recum, A. F. (1984). Applications and failure modes of percutaneous devices: A review. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820180403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.