Neovascularization of synthetic membranes directed by membrane microarchitecture
Abstract
Transplantation of tissues enclosed within a membrane device designed to protect the cells from immune rejection (immunoisolation) provides an opportunity to treat a variety of disease conditions. Successful implementation of immunoisolation has been hampered by the foreign‐body reaction to biomaterials. We screened a variety of commercially available membranes for foreign‐body reactions following implantation under the skin of rats. Histologic analysis revealed that neovascularization at the membrane–tissue interface occurred in several membranes that had pore sizes large enough to allow complete penetration by host cells (0.8‐8‐μm pore size). When the vascularization of the membrane–tissue interface of 5‐μm‐pore‐size polytetrafluoroethylene (PTFE) membranes was compared to 0.02‐μm‐pore‐size PTFE membranes, it was found that the larger pore membranes had 80–100‐fold more vascular structures. The increased vascularization was observed even though the larger pore membrane was laminated to a smaller pore inner membrane to prevent cell entry into the prototype immunoisolation device. This significantly higher level of vascularization was maintained for 1 year in the subcutaneous site in rats. © 1995 John Wiley & Sons, Inc.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Upon rat subdermal implantation, PTFE membranes with 5 μm pore size provided 80-100 times more vascular structures than membranes with 0.02 μm pore size.
“Upon rat subdermal implantation, larger pore membranes provided 80–100 times more vascular structures.”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [140]
Increased vascularization correlated with the ability of inflammatory cells to infiltrate the porous membrane.
“this increased vascularization correlated with the ability of inflammatory cells to infiltrate the porous membrane.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [155]
Membranes with larger pores (5.0 versus 0.02 μm) had 80-100 times greater vascularization in the surrounding tissue.
“Membranes fabricated with the larger pores were characterized by 80–100x greater vascularization in the tissue surrounding the implant.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [155]
Membranes with larger pores also showed increased vascularization at one year.
“The membranes with the larger pores also showed increased vascularization at the one year mark.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [155]
Cited by
Sorted by citations
Hydrogels in regenerative medicine
Slaughter, B. V., Khurshid, S. S., Fisher, O. Z., Khademhosseini, A., & Peppas, N. A. (2009) · Advanced Materials · doi:10.1002/adma.200802106 · Cited by 2,703 · see citing works
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507 · see citing works
Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897 · see citing works
Vegas, A. J., Veiseh, O., Doloff, J. C., Ma, M., Tam, H. H., Bratlie, K., Li, J., Bader, A. R., Langan, E., Olejnik, K., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3462 · Cited by 551 · see citing works
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · see citing works
Advances in islet encapsulation technologies
Desai, T., & Shea, L. D. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.232 · Cited by 427 · see citing works
Sussman, E. M., Halpin, M. C., Muster, J., Moon, R. T., & Ratner, B. D. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0933-0 · Cited by 416 · see citing works
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Scharp, D. W., & Marchetti, P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.018 · Cited by 314 · see citing works
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · see citing works
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186 · see citing works
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176 · see citing works
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
Sanders, J. E., Bale, S. D., & Neumann, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10285 · Cited by 82 · see citing works
Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31824 · Cited by 69 · see citing works
ten Brink, T., Damanik, F., Rotmans, J. I., & Moroni, L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202301939 · Cited by 71 · see citing works
Wisniewski, N., Rajamand, N., Adamsson, U., Lins, P. E., Reichert, W. M., Klitzman, B., & Ungerstedt, U. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00259.2001 · Cited by 50 · see citing works
Collie, A. M. B., Bota, P. C. S., Johns, R. E., Maier, R. V., & Stayton, P. S. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32963 · Cited by 33 · see citing works
Biocompatibility and Bioresponse to Biomaterials
Anderson, J. M. (2019) · Principles of Regenerative Medicine · doi:10.1016/b978-0-12-809880-6.00039-4 · Cited by 33 · see citing works
Ward, W. K., Hansen, J. C., Massoud, R. G., Engle, J. M., Takeno, M. M., & Hauch, K. D. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32651 · Cited by 26 · see citing works
Intravital microscopy evaluation of angiogenesis and its effects on glucose sensor performance
Koschwanez, H. E., Reichert, W. M., & Klitzman, B. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32630 · Cited by 15 · see citing works
Percutaneous Window Chamber Method for Chronic Intravital Microscopy of Sensor—Tissue Interactions
Koschwanez, H. E., Klitzman, B., & Reichert, W. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200608 · Cited by 9 · see citing works
- Authors
- Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C.
- Affiliations
- Baxter (United States) (US)
- Corresponding author
- Brauker, James H.
- ORCID
- Johnson, Robert C.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 29
- Issue
- 12
- Pages
- 1517-1524
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1967264939
- Cited by
- 517
- References
- 0
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 14 · 2023: 12 · 2022: 8 · 2021: 16 · 2020: 25 · 2019: 22 · 2018: 26 · 2017: 25 · 2016: 21 · 2015: 20 · 2014: 18 · 2013: 25 · 2012: 21
- FWCI
- 12.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Keywords
- neovascularization, synthetic membranes, pore size, polytetrafluoroethylene membrane, immunoisolation, foreign body reaction, biomaterial implantation, subcutaneous implantation, vascularization
- MeSH terms
- Animals, Biocompatible Materials, Blood Vessels, Foreign-Body Reaction, Male, Membranes, Artificial, Polytetrafluoroethylene, Porosity, Rats, Sprague-Dawley, Neovascularization, Physiologic, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review