Cited by 517Tissue Engineering and Regenerative MedicineElectrospun Nanofibers in Biomedical ApplicationsPancreatic function and diabetes

Neovascularization of synthetic membranes directed by membrane microarchitecture

Brauker, James H., Carr‐Brendel, Victoria E., Martinson, Laura A., Crudele, Joanne, Johnston, William D., Johnson, Robert C.·1995·Journal of Biomedical Materials Research

Abstract

Transplantation of tissues enclosed within a membrane device designed to protect the cells from immune rejection (immunoisolation) provides an opportunity to treat a variety of disease conditions. Successful implementation of immunoisolation has been hampered by the foreign‐body reaction to biomaterials. We screened a variety of commercially available membranes for foreign‐body reactions following implantation under the skin of rats. Histologic analysis revealed that neovascularization at the membrane–tissue interface occurred in several membranes that had pore sizes large enough to allow complete penetration by host cells (0.8‐8‐μm pore size). When the vascularization of the membrane–tissue interface of 5‐μm‐pore‐size polytetrafluoroethylene (PTFE) membranes was compared to 0.02‐μm‐pore‐size PTFE membranes, it was found that the larger pore membranes had 80–100‐fold more vascular structures. The increased vascularization was observed even though the larger pore membrane was laminated to a smaller pore inner membrane to prevent cell entry into the prototype immunoisolation device. This significantly higher level of vascularization was maintained for 1 year in the subcutaneous site in rats. © 1995 John Wiley & Sons, Inc.

Integrity signals

Registry

Crossref · 10.1002/jbm.820291208

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C.
Affiliations
Baxter (United States) (US)
Corresponding author
Brauker, James H.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1995-12
Volume
29
Issue
12
Pages
1517-1524
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1967264939
Cited by
517
References
0
Citations by year
2026: 4 · 2025: 4 · 2024: 14 · 2023: 12 · 2022: 8 · 2021: 16 · 2020: 25 · 2019: 22 · 2018: 26 · 2017: 25 · 2016: 21 · 2015: 20 · 2014: 18 · 2013: 25 · 2012: 21
FWCI
12.33
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
neovascularization, synthetic membranes, pore size, polytetrafluoroethylene membrane, immunoisolation, foreign body reaction, biomaterial implantation, subcutaneous implantation, vascularization
MeSH terms
Animals, Biocompatible Materials, Blood Vessels, Foreign-Body Reaction, Male, Membranes, Artificial, Polytetrafluoroethylene, Porosity, Rats, Sprague-Dawley, Neovascularization, Physiologic, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review